Automatic microfluidic enzyme-linked immunosorbent assay based on CLOCK-controlled autonomous centrifugal microfluidics

被引:28
|
作者
Okamoto, Shunya [1 ]
Ukita, Yoshiaki [2 ]
机构
[1] Univ Yamanashi, Grad Sch, Integrated Grad Sch Med Engn & Agr Sci, Dept Engn, Kofu, Yamanashi, Japan
[2] Univ Yamanashi, Grad Sch, Grad Fac Interdisciplinary Res, Fac Engn, Kofu, Yamanashi, Japan
关键词
Centrifugal microfluidics; ELISA; Autonomous microfluidic control; Immunoassay; ON-A-DISC; MULTISTEP ASSAYS; FLOW-CONTROL; PLATFORM; VALVES; IMMUNOASSAY; DEVICES; CD;
D O I
10.1016/j.snb.2018.01.150
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports on the development of an autonomous centrifugal microfluidic device, which automatically executes an enzyme-linked immunosorbent assay (ELISA) on a steady rotational frequency. The device was designed on the principles of CLOCK (Control of Liquid Operation on Centrifugal hydroKinetics) to achieve autonomous centrifugal microfluidics. These demonstrations confirmed that the device achieves accurate flow control of an automated ELISA with fluctuations of the interval time for implementation of each unit (antigen-antibody reaction, wash and injection of detection substrate) being less than 5%. The most optimal method for the immobilization of primary antibodies was investigated for the developed platform. We compared three methods of antibody immobilization on the developed platform, by using polystyrene microbeads, a polyurethane foam structure, and direct immobilization to the reaction chamber. We chose the use of polyurethane foam as the best immobilization method based on reaction efficiency and the convenient handling of the immobilized antibody on the solid phase. Measurement of human albumin was demonstrated using the developed device, and a calibration curve of human albumin detection was successfully prepared with an overall assay operation time of 18 min. The limit of detection (LOD) was estimated to be 0.516 ng/ml, which is comparable with the LOD of 0.707 ng/ml obtained by the assay on a conventional titer plate assay platform. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:264 / 270
页数:7
相关论文
共 50 条
  • [21] Early detection of Fasciola gigantica infection in buffaloes by enzyme-linked immunosorbent assay and dot enzyme-linked immunosorbent assay
    Kumar, Niranjan
    Ghosh, S.
    Gupta, S. C.
    PARASITOLOGY RESEARCH, 2008, 103 (01) : 141 - 150
  • [22] Microfluidic enzyme-linked immunosorbent assay using a new kind of substrate for the enzyme-label
    Giri, Basant
    Ngwa, Fidelis
    Corcoran, Robert C.
    Dutta, Debashis
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 246
  • [23] A competitive enzyme-linked immunosorbent assay for diminazene
    Karanja, WM
    Mdachi, RE
    Murilla, GA
    ACTA TROPICA, 2002, 84 (02) : 75 - 81
  • [24] Development of an enzyme-linked immunosorbent assay for pentachlorophenol
    Noguera, P
    Maquieira, A
    Puchades, R
    Brunet, E
    Carramolino, MM
    Rodríguez-Ubis, JC
    ANALYTICA CHIMICA ACTA, 2002, 460 (02) : 279 - 288
  • [25] Enzyme-linked immunosorbent assay for detection of chitooligosaccharides
    Kim, SY
    Shon, DH
    Lee, KH
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2000, 64 (04) : 696 - 701
  • [26] ENZYME-LINKED IMMUNOSORBENT-ASSAY FOR METALLOTHIONEIN
    ABEL, J
    OHNESORGE, FK
    TOXICOLOGY LETTERS, 1980, : 191 - 191
  • [27] Quantification of cibenzoline by enzyme-linked immunosorbent assay
    Saita, Tetsuya
    Tokunaga, Akira
    Egoshi, Masayoshi
    Tokushima, Hideaki
    Fujito, Hiroshi
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2007, 127 (06): : 1007 - 1012
  • [28] AUTOMATION OF ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA)
    CARLIER, Y
    BOUT, D
    CAPRON, A
    JOURNAL OF IMMUNOLOGICAL METHODS, 1979, 31 (3-4) : 237 - 246
  • [29] ENZYME-LINKED IMMUNOSORBENT-ASSAY IN AMEBIASIS
    BAVEJA, UK
    WARHURST, DC
    VOLLAR, A
    INDIAN JOURNAL OF MEDICAL RESEARCH, 1984, 80 (NOV) : 528 - 531
  • [30] DETECTION OF ADENOVIRUS BY ENZYME-LINKED IMMUNOSORBENT ASSAY
    HARMON, MW
    DRAKE, S
    KASEL, JA
    JOURNAL OF CLINICAL MICROBIOLOGY, 1979, 9 (03) : 342 - 346