Investigations on seismic response of two span cable-stayed bridges

被引:7
|
作者
Bhagwat, Madhav [2 ]
Sasmal, Saptarshi [1 ,3 ]
Novak, B. [3 ]
Upadhyay, A. [2 ]
机构
[1] CSIR Struct Engn Res Ctr, Chennai, Tamil Nadu, India
[2] Indian Inst Technol Roorkee, Roorkee, Uttar Pradesh, India
[3] Univ Stuttgart, D-7000 Stuttgart, Germany
关键词
cable-stayed bridge; free vibration; parametric study; seismic response; mode shapes; frequencies; bridge response; time history; GROUND MOTION; BEHAVIOR;
D O I
10.12989/eas.2011.2.4.337
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, cable-stayed bridges with single pylon and two equal side spans, with variations in geometry and span ranging from 120 m to 240 m have been studied. 3D models of the bridges considered in this study have been analysed using ANSYS. As the first step towards a detailed seismic analysis, free vibration response of different geometries is studied for their mode shapes and frequencies. Typical pattern of free vibration responses in different frequencies with change in geometry is observed. Further, three different seismic loading histories are chosen with various characteristics to find the structural response of different geometries under seismic loading. Effect of variation in pylon shape, cable arrangement with variation in span is found to have typical characteristics with different structural response under seismic loading. From the study, it is observed that the structural response is very much dependent on the geometry of the cable-stayed bridge and the characteristics of the seismic loading as well. Further, structural responses obtained from the study would help the design engineers to take decisions on geometric shapes of the bridges to be constructed in seismic prone zones.
引用
收藏
页码:337 / 356
页数:20
相关论文
共 50 条
  • [21] Span limit and parametric analysis of cable-stayed bridges
    Zhao, Xinwei
    Xiao, Rucheng
    Sun, Bin
    STRUCTURAL ENGINEERING AND MECHANICS, 2019, 71 (03) : 271 - 282
  • [22] Bridges - Cable-stayed span to cross Mississippi river
    Aveni, M
    CIVIL ENGINEERING, 2001, 71 (06): : 30 - 30
  • [23] Seismic response characteristics of multispan cable-stayed bridges with stabilizing cables
    Ko, JM
    Ni, YQ
    He, GJ
    EARTHQUAKE ENGINEERING FRONTIERS IN THE NEW MILLENNIUM, 2001, : 227 - 232
  • [24] Influence of soil conditions on the seismic behaviour of two cable-stayed bridges
    Elassaly, Mohamed, 1600, Natl Research Council of Canada, Ottawa, Canada (22):
  • [25] The role of tife stay cables in the seismic response of cable-stayed bridges
    Caetano, E
    Cunha, A
    Taylor, C
    IMAC - PROCEEDINGS OF THE 16TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS 1 AND 2, 1998, 3243 : 1346 - 1352
  • [26] Aerodynamics of two edge girders for long-span cable-stayed bridges
    Matsumoto, M
    Araki, K
    Daito, Y
    FLOW-INDUCED VIBRATION, 2000, : 149 - 156
  • [27] Seismic response analysis of cable-stayed bridges using carbon fiber composite cable
    Department of Civil Engineering, Zhejiang University, Hangzhou 310027, China
    Gongcheng Lixue, 2008, SUPPL. (158-164+183):
  • [28] CABLE-STAYED BRIDGES
    GOLUB, H
    CIVIL ENGINEERING, 1971, 41 (08): : 43 - &
  • [29] CABLE-STAYED BRIDGES
    PODOLNY, W
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1974, 11 (01): : 1 - 11
  • [30] Seismic Response Analysis of Long-span Cable-stayed Bridges Subjected to Multi-support Excitation
    Zheng, Yue
    Xu, You-Lin
    Hu, Liang