Analysis of reliability of EMG signal frequency domain parameters used in the characterization of localized muscle fatigue

被引:5
|
作者
da Silva, Cristiano Rocha [1 ]
Geres, Beatriz Sanches [1 ]
Kuriki, Heloyse Uliam [1 ,2 ]
Negrao Filho, Ruben de Faria [1 ]
Alves, Neri [1 ,2 ]
de Azevedo, Fabio Micolis [1 ]
机构
[1] UNESP Univ Estadual Paulista, Fac Ciencias & Tecnol, Lab Biomecan & Controle Motor, Presidente Prudente, SP, Brazil
[2] Univ Sao Paulo, Programa Posgrad Interunidades Bioengn EESC FMRP, Sao Carlos, SP, Brazil
来源
MOTRIZ-REVISTA DE EDUCACAO FISICA | 2012年 / 18卷 / 03期
基金
巴西圣保罗研究基金会;
关键词
Electromyography; Fatigue; Reproducibility of results; Biomechanics; Quadriceps muscle; Median frequency; SURFACE ELECTROMYOGRAPHY; ISOMETRIC CONTRACTIONS; QUADRICEPS FEMORIS; MEDIAN FREQUENCY; AMPLITUDE; EXERCISE; CAPACITY; HUMANS; FORCE;
D O I
10.1590/S1980-65742012000300006
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The aim of this study was to analyze the reproducibility of the electromyography signal's parameters (EMG) in the frequency domain used in the characterization of localized muscle fatigue. Fifteen male subjects underwent a fatigue test based on isometric knee extension, being held at three different times at intervals of seven days. To assess the reproducibility of data between the tests we calculated the correlation coefficient (ICC) for the median frequency (MF) in total exercise time (MFT), MF obtained for every 10% of exercise time (MF10%) and the powers of the frequency bands obtained by dividing the power spectrum at windows of 20 Hz. The results showed: (1) excellent reproducibility for MFT, (2) good reproducibility for MF10%, and (3) greater variation in the signal EMG bands from 20 to 120 Hz, especially at the bands of 20-40 Hz and 40-60 Hz, which showed greater sensitivity to the process of muscle fatigue. We conclude that the MF is a variable that shows good reproducibility and that the fragmented analysis of the power spectrum, by means of frequency bands, showed that significant variations occur in the EMG signal during the installation of the fatigue process, having potential to become a new method for the characterization of localized muscle fatigue.
引用
收藏
页码:456 / 464
页数:9
相关论文
共 50 条
  • [21] Rate of change in surface emg median frequency as a measure of muscle fatigue
    Roberts, N. M.
    White, K. T.
    Kim, K. J.
    Easterling, C.
    Wertsch, J. J.
    MUSCLE & NERVE, 2006, 34 (04) : 518 - 519
  • [22] EVALUATION OF THE AMPLITUDE AND FREQUENCY COMPONENTS OF THE SURFACE EMG AS AN INDEX OF MUSCLE FATIGUE
    PETROFSKY, JS
    GLASER, RM
    PHILLIPS, CA
    LIND, AR
    WILLIAMS, C
    ERGONOMICS, 1982, 25 (03) : 213 - 223
  • [23] A Comparison Of Fatigue Thresholds Derived From The Frequency Domain Of The Electromyographic Signal And Gas Exchange Parameters
    Camic, Clayton L.
    Housh, Terry J.
    Hendrix, C. Russell
    Zuniga, Jorge
    Johnson, Glen O.
    Housh, Dona J.
    Schmidt, Richard J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (05): : 749 - 749
  • [24] Analysis of Muscle Fatigue Conditions in Surface EMG Signal with A Novel Hilbert Marginal Spectrum Entropy Method
    Jero, S. Edward
    Ramakrishnan, S.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 2675 - 2678
  • [25] Fatigue analysis of the surface EMG signal in isometric constant force contractions using the averaged instantaneous frequency
    Georgakis, A
    Stergioulas, LK
    Giakas, G
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (02) : 262 - 265
  • [26] Mean frequency derived via Hilbert-Huang transform with application to fatigue EMG signal analysis
    Xie, Hongbo
    Wang, Zhizhong
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 82 (02) : 114 - 120
  • [27] FREQUENCY ANALYSIS OF EMG AS USED IN PRACTICAL CLINICAL WORK
    LARSSON, LE
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1969, 26 (03): : 343 - &
  • [28] Reliability of EMG time-frequency measures of fatigue during repetitive lifting
    Ebenbiçhler, GR
    Bonato, P
    Roy, SH
    Lehr, S
    Posch, M
    Kollmitzer, J
    Della Croce, U
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (08): : 1316 - 1323
  • [29] EMG COMPUTERIZED ANALYSIS OF LOCALIZED FATIGUE IN DUCHENNE MUSCULAR-DYSTROPHY
    FRASCARELLI, M
    ROCCHI, L
    FEOLA, I
    MUSCLE & NERVE, 1988, 11 (07) : 757 - 761
  • [30] INTERRELATIONSHIPS OF EMG SIGNAL CHARACTERISTICS AT DIFFERENT LEVELS OF MUSCLE TENSION AND DURING FATIGUE
    VIITASALO, JT
    KOMI, PV
    ELECTROMYOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1978, 18 (3-4): : 167 - 178