Clinical Features and Outcomes of Cardiovascular Implantable Electronic Device Infections Due to Staphylococcal Species

被引:32
|
作者
Le, Katherine Y. [1 ]
Sohail, Muhammad R. [2 ]
Friedman, Paul A. [3 ]
Uslan, Daniel Z. [4 ]
Cha, Stephen S. [5 ]
Hayes, David L. [3 ]
Wilson, Walter R. [2 ]
Steckelberg, James M. [2 ]
Baddour, Larry M. [2 ]
机构
[1] Mayo Clin, Mayo Sch Grad Med Educ, Rochester, MN 55905 USA
[2] Mayo Clin, Div Infect Dis, Rochester, MN USA
[3] Mayo Clin, Dept Med, Div Cardiovasc Dis, Rochester, MN USA
[4] Mayo Clin, Div Biostat & Informat, Rochester, MN USA
[5] Univ Calif Los Angeles, David Geffen Sch Med, Dept Med, Div Infect Dis, Los Angeles, CA 90095 USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2012年 / 110卷 / 08期
关键词
CARDIOVERTER-DEFIBRILLATORS; PERMANENT PACEMAKER; AUREUS BACTEREMIA; ENDOCARDITIS; MANAGEMENT; EPIDERMIDIS;
D O I
10.1016/j.amjcard.2012.05.052
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Staphylococci account for the bulk of cardiovascular implantable electronic device (CIED) infections. However, a detailed analysis of clinical features and outcomes of CIED infections due to staphylococcal species has not been published. We retrospectively reviewed all cases of CIED infection seen at the Mayo Clinic from 1991 through 2008. Differences in device and host factors, clinical features, and patient outcomes were compared between cases of early and late Staphylococcus aureus and coagulase-negative staphylococci (CoNS) CIED infections. Of 280 cases of staphylococcal CIED infections, 43.9% were due to S. aureus and 56.0% were due to CoNS. Staphylococcus aureus CIED infection cases more frequently involved initially implanted devices. Late S. aureus CIED infection cases compared to late CoNS cases were associated with corticosteroid therapy, hemodialysis, implanted catheters, prosthetic valves, and remote sources of bacteremia. Cases of S. aureus endovascular infections had longer duration of bacteremia (56.0% vs 20.3% >= 3 days), longer hospitalization (37.4% vs 15.2% >20 days), and increased mortality (25.2% vs 9.5%) compared to cases of CoNS endovascular infections (p <0.001 for all comparisons). Overall, CoNS CIED infections compared to S. aureus were associated with a history of multiple device revisions and a higher number of total and abandoned leads at presentation (p <0.001 for all comparisons). In conclusion, CIED infections due to S. aureus and CoNS have distinct clinical features and outcomes. (C) 2012 Elsevier Inc. All rights reserved. (Am J Cardiol 2012;110:1143-1149)
引用
收藏
页码:1143 / 1149
页数:7
相关论文
共 50 条
  • [21] Treatment and Prevention of Cardiovascular Implantable Electronic Device (CIED) Infections
    Phillips, Peter
    Krahn, Andrew D.
    Andrade, Jason G.
    Chakrabarti, Santabhanu
    Thompson, Christopher R.
    Harris, David J.
    Forman, Jacqueline M.
    Karim, Shahzad S.
    Sterns, Laurence D.
    Fedoruk, Lynn M.
    Partlow, Eric
    Bashir, Jamil
    CJC OPEN, 2022, 4 (11) : 946 - 958
  • [22] CARDIOVASCULAR IMPLANTABLE ELECTRONIC DEVICE INFECTIONS IN LEFT VENTRICULAR ASSIST DEVICE RECIPIENTS
    Riaz, Talha
    Nienaber, Juhsien J. C.
    Baddour, Larry M.
    Walker, Randall C.
    Park, Soon J.
    Sohail, Muhammad
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E289 - E289
  • [23] Cardiovascular implantable device infections
    Viola G.M.
    Darouiche R.O.
    Current Infectious Disease Reports, 2011, 13 (4) : 333 - 342
  • [24] Cardiovascular Implantable Electronic Device Infections in Left Ventricular Assist Device Recipients
    Riaz, Talha
    Nienaber, Juhsien J. C.
    Baddour, Larry M.
    Walker, Randall C.
    Park, Soon J.
    Sohail, Muhammad Rizwan
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (02): : 225 - 230
  • [25] Microbiological Characteristics and Clinical Features of Cardiac Implantable Electronic Device Infections at a Tertiary Hospital in China
    Wang, Ruobing
    Li, Xuebin
    Wang, Qi
    Zhang, Yawei
    Wang, Hui
    FRONTIERS IN MICROBIOLOGY, 2017, 8
  • [26] Outcomes Of Cardiovascular Implantable Electronic Device Associated Infections In Patients Supported With Left Ventricular Assist Devices
    Hayat, Fatima
    Lam, Phillip H.
    Rao, Sriram D.
    Afari-Armah, Nana
    Gupta, Richa
    Kadakkal, Ajay
    Rodrigo, Maria E.
    Hofmeyer, Mark
    Najjar, Samer S.
    Molina, Ezequiel J.
    Ruiz, Maria Elena
    Sheikh, Farooq H.
    JOURNAL OF CARDIAC FAILURE, 2023, 29 (04) : 603 - 603
  • [27] Incidence and outcomes of cardiovascular implantable electronic device infections in patients with end-stage kidney disease
    Jiwani, Sania
    Chan, Wan-Chi
    Gadre, Akshaya
    Sheldon, Seth
    Hu, Jinxiang
    Pimentel, Rhea
    Noheria, Amit
    Gupta, Kamal
    HEART RHYTHM, 2025, 22 (03)
  • [28] Outcomes of Transvenous Lead Extraction for Cardiovascular Implantable Electronic Device Infections in Patients With Prosthetic Heart Valves
    Huang, Xin-miao
    Fu, Hai-xia
    Zhong, Li
    Cao, Jiang
    Asirvatham, Samuel J.
    Baddour, Larry M.
    Sohail, M. Rizwan
    Nkomo, Vuyisile T.
    Nishimura, Rick A.
    Greason, Kevin L.
    Suri, Rakesh M.
    Friedman, Paul A.
    Cha, Yong-Mei
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (09):
  • [29] Procalcitonin plasma level and microbiology in cardiovascular implantable electronic device infections
    Heine, T.
    Knopp, H.
    Karnbach, A.
    Muessigbrodt, A.
    Arya, A.
    Doering, M.
    Hindricks, G.
    Richter, S.
    EUROPEAN HEART JOURNAL, 2013, 34 : 594 - 595
  • [30] Cardiovascular implantable electronic device infections: associated risk factors and prevention
    Rohacek, Martin
    Baddour, Larry M.
    SWISS MEDICAL WEEKLY, 2015, 145