Clamp fixation to prevent unfolding of a suture knot decreases tensile strength of polypropylene sutures

被引:6
|
作者
Turker, Mehmet [1 ]
Yalcinozan, Mehmet [1 ]
Cirpar, Meric [1 ]
Cetik, Ozgur [1 ]
Kalaycioglu, Baris [2 ]
机构
[1] Kirikkale Univ, Fac Med, Dept Orthoped & Traumatol, Kirikkale, Turkey
[2] Kirikkale Univ, Dept Mech Engn, Kirikkale, Turkey
关键词
Polypropylene; Suture; Tensile strength; Knot security; Surgical knot; ARTHROSCOPIC KNOTS; LOOP SECURITY; POLYBLEND;
D O I
10.1007/s00167-012-1882-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Although sutures evolved in last decade and the product spectrum broadened largely, they can be still classified into two: monofilament and multifilament. Sutures are the mainstay of orthopedic procedures like fascial closures, tendon repairs or tenodesis. In every repair, a suture loop is created. This suture loop is prone to failure due to suture elongation, knot slip and suture breakage. As the knot is the stress riser in a suture loop, the majority of acute loop failure occurs just adjacent to the knot. Monofilament sutures have higher bending stiffness and tendency to untie than multifilament sutures. The first throw of monofilament sutures have tendency to untie, which decrease loop tension and result in loss of achieved tissue approximation. Methods Although a common practice is to fix the first throw via a clamp before the locking one is tied, it can be hypothesized that a potential deforming effect can lead to a decrease in ultimate failure load of a monofilament suture loop. Results Fixing the first throw significantly reduced the ultimate failure load of monofilament nonabsorbable polypropylene sutures (Prolene) (62.2 +/- 8 N vs. 72.7 +/- 9 N, p = 0.019). The ultimate failure load achieved by monofilament sutures Polyglyconate (Maxon) and Nylon (Ethilon) and braided absorbable Polyglactin (Vicryl) were not affected by fixing the first throw. Conclusion Under microscopic examination, polypropylene sutures were found to be deformed by clamp fixation, while the others were not. Polypropylene sutures can be easily damaged when it is fixed by a clamp during knot tying. Presented data demonstrated that in real surgical situations clamp fixation of polypropylene knots can damage the suture loop and carry the risk of acute failure of repair site during early rehabilitation.
引用
收藏
页码:2602 / 2605
页数:4
相关论文
共 33 条
  • [21] A Biomechanical Comparison of High-Tensile Strength Tape Versus High-Tensile Strength Suture for Tendon Fixation Under Cyclic Loading
    Le, Anthony H.
    Roach, William B.
    Mauntel, Timothy C.
    Hendershot, Brad D.
    Helgeson, Melvin D.
    Colantonio, Donald F.
    Fredericks, Donald R.
    Slaven, Sean E.
    Pisano, Alfred J.
    LeClere, Lance E.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2021, 37 (09): : 2925 - 2933
  • [22] Risk of Glove Perforation With Arthroscopic Knot Tying Using Different Surgical Gloves and Highe-Tensile Strength Sutures
    Martinez, Adriana
    Han, Yung
    Sardar, Zeeshan M.
    Beckman, Lorne
    Steffen, Thomas
    Miller, Bruce S.
    Martineau, Paul A.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (09): : 1552 - 1558
  • [23] ABSORBABLE SUTURE MATERIALS FOR VASCULAR ANASTOMOSES - TENSILE-STRENGTH AND AXIAL PRESSURE STUDIES USING POLYGLYCOLIC ACID SUTURES
    ROSS, G
    PAVLIDES, C
    LONG, F
    KUSABA, A
    PERLMAN, M
    MATSUMOTO, T
    AMERICAN SURGEON, 1981, 47 (12) : 541 - 547
  • [24] EFFECT OF SUTURE METHOD ON RATE OF GAIN OF TENSILE-STRENGTH IN SKIN WOUNDS - COMPARISON OF SKIN CLIPS WITH INTERRUPTED NYLON SUTURES
    HARRISON, ID
    WILLIAMS, DF
    CUSCHIER.A
    BRITISH JOURNAL OF SURGERY, 1974, 61 (11) : 920 - 920
  • [25] The influence of oblique sutures and tendon-suture anchorages on tensile resistance and ultimate strength of 4-strand tendon repairs
    Xu, Si Wei
    Sun, Li Han
    Wu, Ya Fang
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2025, 50 (02) : 214 - 221
  • [26] Evaluation of Acute Fixation Strength for Mechanical Tacking Devices and Fibrin Sealant Versus Polypropylene Suture for Laparoscopic Ventral Hernia Repair
    Melman, Lora
    Jenkins, Eric D.
    Deeken, Corey R.
    Brodt, Michael D.
    Brown, Shaun R.
    Brunt, L. Michael
    Eagon, J. Christopher
    Frisella, Margaret
    Matthews, Brent D.
    SURGICAL INNOVATION, 2010, 17 (04) : 285 - 290
  • [27] 8-0 Polypropylene Suture Looping and Overhand Knot: Transconjunctival Approach to Four-Point Scleral Fixation of an Akreos Adapt Intraocular Lens
    Chen, Shijiu
    Yuan, Gongqiang
    Zhu, Wenhua
    Shan, Tianhui
    Liu, Chunli
    Zhang, Jingjing
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (05): : 860 - 863
  • [28] Analysis of the efficacy of Endobutton plate combined with high-strength suture Nice knot fixation in the treatment of distal clavicle fractures with coracoclavicular ligament injuries
    Liu, Bin
    Shi, Lei
    Ma, Huifang
    Yu, Haiyang
    Jiang, Jishi
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [29] Evaluation of adhesion formation, mesh fixation strength, and hydroxyproline content after intraabdominal placement of polytetrafluoroethylene mesh secured using titanium spiral tacks, nitinol anchors, and polypropylene suture or polyglactin 910 suture
    Joels, CS
    Matthews, BD
    Kercher, KW
    Austin, C
    Norton, HJ
    Williams, TC
    Heniford, BT
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2005, 19 (06): : 780 - 785
  • [30] Evaluation of adhesion formation, mesh fixation strength, and hydroxyproline content after intraabdominal placement of polytetrafluoroethylene mesh secured using titanium spiral tacks, nitinol anchors, and polypropylene suture or polyglactin 910 suture
    C. S. Joels
    B. D. Matthews
    K. W. Kercher
    C. Austin
    H. J. Norton
    T. C. Williams
    B. T. Heniford
    Surgical Endoscopy And Other Interventional Techniques, 2005, 19 : 780 - 785