The study of improving the strip flatness in run-out-table during laminar cooling

被引:13
|
作者
Wu, Wei-Lin [1 ]
Wang, Wei-Cheng [1 ]
Lo, Wei [2 ]
机构
[1] Natl Cheng Kung Univ, Dept Aeronaut & Astronaut, Tainan 70101, Taiwan
[2] China Steel Corp, Kaohsiung 81233, Taiwan
关键词
Run-out-table (ROT); Hot rolled strip; Residual stress; Laminar cooling; Strip phase transformation; Heat transfer coefficient; PHASE-TRANSFORMATION; WATER FILM; STEEL; MODEL; MILL; BEHAVIOR;
D O I
10.1007/s00170-017-1558-5
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The heat transfer mechanism during laminar cooling before the down coiler of the run-out-table (ROT) process is a metallurgical key for maintaining the quality of the steel strip. Large variation of the temperature profile along the strip forms residual stress, resulting in the strip distortion. This study developed a computational model through the commercial software Simufact (TM) to analyze the temperature history and deformation, for the purpose of precisely predicting the behaviors of phase transformation during laminar cooling on ROT. This model simulated a specific case, HM690T, provided by the steel factory of which the mechanical properties are computed through JMatPro (TM). The model was first verified in accordance with the field data of temperature profile and experimental measurements of residual stress obtained from the steel company, based on the cooling process provided by the top and bottom water banks. The simulation model was then applied to predict the deformations at each cooling stage and the secondary deformations resulted from alternative cooling of water and air. In addition, the stresses, deformation, and phase transformation for various cooling patterns and cooling periods were simulated based on the developed model, and the optimal ratio of cooling periods of the top and bottom banks was determined. The analysis helps solve the problem of strip flatness during cooling stage on ROT.
引用
收藏
页码:4419 / 4437
页数:19
相关论文
共 50 条
  • [31] DEVELOPMENT OF COOLING CONTROL WITH CURTAIN-WALL-COOLING FOR HOT STRIP .2. DEVELOPMENT OF CONTROL-SYSTEM FOR RUN OUT TABLE COOLING
    OSHIMA, K
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 : 1152 - 1152
  • [32] Optimizing speed of a run-out table of the hot strip mill
    Sergey Ivanovich Luk’yanov
    Nikolay Vladimirovich Shvidchenko
    Sergey Sergeevich Krasilnikov
    Roman Sergeevich Pishnograev
    Dmitriy Vladimirovich Shvidchenko
    Maksim Vladimirovich Konovalov
    The International Journal of Advanced Manufacturing Technology, 2019, 105 : 1675 - 1684
  • [33] Optimizing speed of a run-out table of the hot strip mill
    Luk'yanov, Sergey Ivanovich
    Shvidchenko, Nikolay Vladimirovich
    Krasilnikov, Sergey Sergeevich
    Pishnograev, Roman Sergeevich
    Shvidchenko, Dmitriy Vladimirovich
    Konovalov, Maksim Vladimirovich
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2019, 105 (1-4): : 1675 - 1684
  • [34] Investigation of strip cooling behavior in the run-out section of hot strip mills
    ARMCO Research & Technology, Middletown, United States
    J Mater Process Manuf Sci, 4 (339-351):
  • [35] Investigation of strip cooling behavior in the run-out section of hot strip mills
    Guo, RM
    Hwang, ST
    JOURNAL OF MATERIALS PROCESSING & MANUFACTURING SCIENCE, 1996, 4 (04): : 339 - 351
  • [36] A model for determination of austenite decomposition kinetics during continuous cooling on the run-out table
    Serajzadeh, S
    Mirbagheri, SMH
    MODELLING AND SIMULATION IN MATERIALS SCIENCE AND ENGINEERING, 2006, 14 (02) : 217 - 228
  • [37] A model for high carbon steel phase transformation and cooling behavior on run-out table of hot strip mill
    Han, HN
    Lee, JK
    METALS AND MATERIALS-KOREA, 2000, 6 (05): : 401 - 406
  • [38] A model for high carbon steel phase transformation and cooling behavior on run-out table of hot strip mill
    Heung Nam Han
    Jae Kon Lee
    Metals and Materials, 2000, 6 : 401 - 406
  • [39] Nozzle Arrangement for Optimal Performance of Cooling Process of Run Out Table
    Kwon, Myeon Jae
    Park, Il Seouk
    ISIJ INTERNATIONAL, 2013, 53 (12) : 2192 - 2196
  • [40] Evaluation method for hot rolling & run out table cooling parameters
    Taylor, T.
    Sugiyama, S.
    Ishikawa, A.
    Wang, H.
    Yanagimoto, J.
    MATERIALS SCIENCE AND TECHNOLOGY, 2021, 37 (17) : 1386 - 1403