Experimental Performance Evaluation of Multi-Storey Steel Plate Shear Walls Designed by Different Methods

被引:12
|
作者
Xu, Tao [1 ]
Shao, Jian-Hua [1 ]
Zhang, Ji-Ye [1 ]
Kaewunruen, Sakdirat [2 ]
机构
[1] Jiangsu Univ Sci & Technol, Nanxu Rd, Zhenjiang, Jiangsu, Peoples R China
[2] Univ Birmingham, UOB, Gisbert Kapp Bldg G8, Edgbaston B15 2TT, England
基金
中国国家自然科学基金;
关键词
Steel plate shear wall; Performance evaluation; Ductility; Over-strength factor; Strength assurance coefficient; STRUCTURAL PERFORMANCE; LIGHT-GAUGE; BEHAVIOR;
D O I
10.1007/s40999-018-0374-0
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In accordance with two different design methods including the technical specification for steel structures of tall buildings and the shear-bearing capacity method for infilled steel wall plates, two types of steel plate shear wall with unstiffened panels have been designed and constructed. All shear wall specimens are exposed to ultimate static monotonic and low horizontal cyclic loading conditions to determine their structural behaviors under an idealized severe earthquake event. The seismic performances of these two types of specimens are identified by the overall roof displacement angle, lateral stiffness, ductility, different distribution of horizontal force and overturning moment, and inclined angle of diagonal tension field. These two types of steel plate shear wall exhibit excellent seismic performance. However, the specimens with thin infill plate thickness of 1.1mm perform better than the thicker specimens with plate thickness of 3.75mm. In terms of serviceability performance, the experimental results exhibit that the thicker specimens designed by the technical specification tend to be more conservative. Their over-strength factor, strength assurance coefficient and drift angle are 4.98, 6.3 and 1/1335, respectively. However, the thinner specimens designed by the shear capacity method for shear panel yield the serviceability performance factors of 2.22, 2.71 and 1/407, respectively. It is important to note that design practice generally adopts the over-strength factor between 2 and 3, and the strength assurance coefficient is often designed for 3 and the maximum inter-story drift limit given by the design specification is 1/300. On this ground, it is apparent that the shear-bearing capacity method enables relatively more economical compared to the technical specification for steel structures.
引用
收藏
页码:1145 / 1154
页数:10
相关论文
共 50 条
  • [1] Experimental Performance Evaluation of Multi-Storey Steel Plate Shear Walls Designed by Different Methods
    Tao Xu
    Jian-Hua Shao
    Ji-Ye Zhang
    Sakdirat Kaewunruen
    International Journal of Civil Engineering, 2019, 17 : 1145 - 1154
  • [2] Seismic shear demands in multi-storey steel frames designed to Eurocode 8
    Kumar, M.
    Stafford, P. J.
    Elghazouli, A. Y.
    ENGINEERING STRUCTURES, 2013, 52 : 69 - 87
  • [3] Experimental research on seismic performance of multi-story steel plate shear walls designed by the shear bearing capacity of plate
    Shao, Jian-Hua
    Gu, Qiang
    Tang, Bai-Jian
    Wang, Zhi-Jun
    Gongcheng Lixue/Engineering Mechanics, 2015, 32 (04): : 54 - 61
  • [4] Experimental studies of new ductile coupling beams and multi-storey shear walls
    Dajun, Ding
    Zhengliang, Cao
    Shuanji, Zhang
    Materials and Structures/Materiaux et Constructions, 1997, 30 (203): : 566 - 573
  • [5] Experimental studies of new ductile coupling beams and multi-storey shear walls
    Ding, D
    Cao, ZL
    Zhang, SJ
    MATERIALS AND STRUCTURES, 1997, 30 (203): : 566 - 573
  • [6] Experimental studies of new ductile coupling beams and multi-storey shear walls
    Ding Dajun
    Cao Zhengliang
    Zhang Shuangji
    Materials and Structures, 1997, 30 (9) : 566 - 573
  • [7] Experimental and numerical study on the deflection of multi-storey light-frame timber shear walls
    Bagheri, M. M.
    Doudak, G.
    ENGINEERING STRUCTURES, 2021, 233
  • [8] MULTI-STOREY FRAMES AND INTERCONNECTED SHEAR-WALLS SUBJECTED TO LATERAL LOADS
    PORTER, DM
    CONCRETE AND CONSTRUCTIONAL ENGINEERING, 1966, 61 (07): : 262 - &
  • [9] Nonlinear seismic performance of code designed perforated steel plate shear walls
    Barua, Kallol
    Bhowmick, Anjan K.
    STEEL AND COMPOSITE STRUCTURES, 2019, 31 (01): : 85 - 98
  • [10] Performance index and damage evaluation of steel plate shear walls
    Sun, Guohua
    Gu, Qiang
    He, Ruoquan
    Fang, Youzhen
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2013, 46 (04): : 46 - 56