Aperture shape optimization for IMRT treatment planning

被引:33
|
作者
Cassioli, A. [1 ]
Unkelbach, J. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 02期
关键词
GENETIC ALGORITHM; RADIATION-THERAPY; COLUMN GENERATION; SHOOT IMRT; RADIOTHERAPY; SEGMENTS;
D O I
10.1088/0031-9155/58/2/301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose an algorithm for aperture shape optimization (ASO) for step and shoot delivery of intensity-modulated radiotherapy. The method is an approach to direct aperture optimization (DAO) that exploits gradient information to locally optimize the positions of the leafs of a multileaf collimator. Based on the dose-influence matrix, the dose distribution is locally approximated as a linear function of the leaf positions. Since this approximation is valid only in a small interval around the current leaf positions, we use a trust-region like method to optimize the leaf positions: in one iteration, the leaf motion is confined to the beamlets where the leaf edges are currently positioned. This yields a well-behaved optimization problem for the leaf positions and the aperture weights, which can be solved efficiently. If, in one iteration, a leaf is moved to the edge of a beamlet, the leaf motion can be confined to the neighboring beamlet in the next iteration. This allows for large leaf position changes over the course of the algorithm. In this paper, the ASO algorithm is embedded into a column-generation approach to DAO. After a new aperture is added to the treatment plan, we use the ASO algorithm to simultaneously optimize aperture weights and leaf positions for the new set of apertures. We present results for a paraspinal tumor case, a prostate case and a head and neck case. The computational results indicate that, using this approach, treatment plans close to the ideal fluence map optimization solution can be obtained.
引用
收藏
页码:301 / 318
页数:18
相关论文
共 50 条
  • [31] Behavior of a Treatment Planning System Optimization Engine when using Aperture Shape Control to Affect Arc Modulation
    McDonald, D. G.
    Mart, C.
    Rapchak, A. K.
    Owen, G.
    Fallon, K.
    Godwin, W.
    Broekhoven, B.
    Hilliard, E.
    Peng, J. L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E290 - E290
  • [32] The use of aperture shape controller and convergence mode in radiotherapy treatment planning
    Rossi, Maija
    Boman, Eeva
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (02) : 171 - 178
  • [33] Robust Direct Aperture Optimization for Radiation Therapy Treatment Planning
    Ripsman, Danielle A.
    Purdie, Thomas G.
    Chan, Timothy C. Y.
    Mahmoudzadeh, Houra
    INFORMS JOURNAL ON COMPUTING, 2022, 34 (04) : 2017 - 2038
  • [34] Equivalent uniform dose (EUD) based optimization for IMRT treatment planning
    Mihailidis, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2295 - 2295
  • [35] Mixed integer programming techniques applied to IMRT treatment planning optimization
    Lee, E
    Fox, T
    Crocker, I
    MEDICAL PHYSICS, 2002, 29 (06) : 1259 - 1259
  • [36] Fluence map optimization in IMRT cancer treatment planning and a geometric approach
    Zhang, Y
    Merritt, M
    MULTISCALE OPTIMIZATION METHODS AND APPLICATIONS, 2006, 82 : 205 - +
  • [37] Iterative Optimization Method for IMRT Treatment Planning of Patients with Prosthetic Hardware
    Peskorski, D.
    Lalonde, R.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [38] IMRT treatment planning with direct optimization of step-and-shoot segments
    Larsson, M
    Rehbinder, H
    Löf, J
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S345 - S345
  • [39] A MLC Leaf Sequencing Algorithm Restricted by the Shape of Aperture for IMRT
    Jing, J.
    Lin, H.
    Zhang, B.
    Chow, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E317 - E317
  • [40] HOW CAN IMRT SOLUTION EVOLVE? IMRT OPTIMIZATION MODULE FOR ALFARD TREATMENT PLANNING SYSTEM.
    Swat, K.
    Andrasiak, M.
    Kaminski, P.
    Masternak, A.
    Kopec, J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S501 - S502