A low-volume, single pass in-vitro system of high shear thrombosis in a stenosis

被引:21
|
作者
Para, Andrea N. [1 ]
Ku, David N. [1 ]
机构
[1] Georgia Inst Technol, Atlanta, GA 30332 USA
关键词
Thrombosis; Whole Blood; High Shear Rates; Stenosis; Platelets; Accumulation; VON-WILLEBRAND-FACTOR; PLATELET-AGGREGATION; WALL SHEAR; ADENOSINE-DIPHOSPHATE; ASPIRIN RESISTANCE; WHOLE-BLOOD; ADHESION; FLOW; P2Y(12); CLOPIDOGREL;
D O I
10.1016/j.thromres.2013.02.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Arterial thrombosis leading to heart attack and stroke requires the rapid accumulation of millions of platelets under pathologically high shear. Previous in vitro systems studying platelets typically use endpoints that emphasize platelet-surface effects rather than large-scale platelet-platelet accumulation that precedes occlusion. Further, most platelet tests do not recreate shear rates present during arterial occlusion. We present an alternative flow system to study large thrombus formation under pathologic shear conditions in an anatomic stenosis with reasonable volumes of human blood. Materials and Methods: An in-vitro system using a syringe pump was created to subject low volume (<30mLs), whole blood samples to very high shear rates (>3,500 s(-1)) through a stenosis. Thrombus was quantified using an optical microscope from initial deposition to large scale accumulation. Images were taken using a high definition camera in real time. Results and Conclusions: Occlusive thrombus blocks the collagen-coated lumen with millions of platelets using human whole, heparinized blood. Rapid Platelet Accumulation rates in human blood are 4.5 +/- 2.4 mu m(3)/mu m(2)/min (n = 21). There is an initial lag time of 7.4 +/- 3.8 min (n = 21) before the onset of large scale thrombosis. The rates of platelet accumulation in vitro are consistent with the clinical timescale of coronary or carotid artery occlusion. Porcine blood has a faster accumulation rate of 9.6 +/- 6.1 mu m(3)/mu m(2)/min (n = 7, p < 0.05) and a shorter lag time of 2.7 +/- 0.5 min (n = 7, p < 0.05). The long lag time for large thrombus formation suggests that some in-vitro assays will miss the main mechanism creating thrombotic occlusion. (C) 2013 Published by Elsevier Ltd.
引用
收藏
页码:418 / 424
页数:7
相关论文
共 50 条
  • [31] A DETAILED MODEL FOR A HIGH-MIX LOW-VOLUME ASIC FAB
    Gissrau, Mike
    Rose, Oliver
    PROCEEDINGS OF THE 2011 WINTER SIMULATION CONFERENCE (WSC), 2011, : 1948 - 1958
  • [32] COMPARISON OF PTCA OUTCOME AND COSTS FOR HIGH- AND LOW-VOLUME OPERATORS
    SHOOK, TL
    SUN, GW
    HAMMER, J
    JUNIO, LN
    MANN, JD
    BURSTEIN, S
    EISENHAUER, AC
    MATTHEWS, RV
    CIRCULATION, 1993, 88 (04) : 144 - 144
  • [33] Low-volume high-intensity interval training for cardiometabolic health
    Sabag, Angelo
    Little, Johnathan P.
    Johnson, Nathan A.
    JOURNAL OF PHYSIOLOGY-LONDON, 2022, 600 (05): : 1013 - 1026
  • [34] Differences in energy expenditure between high- and low-volume training
    Drenowatz, Clemens
    Eisenmann, Joey C.
    Pivarnik, James M.
    Pfeiffer, Karin A.
    Carlson, Joseph J.
    EUROPEAN JOURNAL OF SPORT SCIENCE, 2013, 13 (04) : 422 - 430
  • [35] A simulation-based approach to design an automated high-mix low-volume manufacturing system
    Herps, Koen
    Dang, Quang-Vinh
    Martagan, Tugce
    Adan, Ivo
    JOURNAL OF MANUFACTURING SYSTEMS, 2022, 64 : 1 - 18
  • [36] Impact of Resource Allocation Policies on Lead Time in a High-Mix Low-Volume Production System
    Liyanaarachchi N.
    Akasaka S.
    Weng J.
    Journal of Japan Industrial Management Association, 2022, 73 (02) : 136 - 144
  • [37] Expert System for Design of Low-Volume Roads over Expansive Soils
    Wanyan, Yaqi
    Abdallah, Imad
    Nazarian, Soheil
    Puppala, Anand J.
    TRANSPORTATION RESEARCH RECORD, 2010, (2154) : 81 - 90
  • [38] A lean production control system for high-variety/low-volume environments: a case study implementation
    Slomp, Jannes
    Bokhorst, Jos A. C.
    Germs, Remco
    PRODUCTION PLANNING & CONTROL, 2009, 20 (07) : 586 - 595
  • [39] High-throughput ADMET profiling employing a low-volume parallel liquid chromatography-system
    Guazzotti, Sergio A.
    Bilboa, Sheila
    AMERICAN LABORATORY, 2007, 39 (19) : 10 - 11
  • [40] Low-volume and high-efficiency converter solution for interfacing a Hybrid Energy Storage System (HESS)
    de Freitas, C. Fonseca
    Bartholomeus, P.
    Margueron, X.
    Le Moigne, P.
    2021 IEEE VEHICLE POWER AND PROPULSION CONFERENCE (VPPC), 2021,