Quantitative assessment of tumor angiogenesis using real-time motion-compensated contrast-enhanced ultrasound imaging

被引:27
|
作者
Pysz, Marybeth A. [1 ]
Guracar, Ismayil [2 ]
Foygel, Kira [1 ]
Tian, Lu [3 ]
Willmann, Juergen K. [1 ]
机构
[1] Stanford Univ, Mol Imaging Program Stanford, Dept Radiol, Sch Med, Stanford, CA 94305 USA
[2] Siemens Healthcare, Ultrasound Business Unit, Mountain View, CA USA
[3] Stanford Univ, Dept Hlth Res & Policy, Stanford, CA 94305 USA
关键词
Maximum intensity persistence; MIP; Cancer; Ultrasound; Microbubbles; Vascular disrupting agent; VDA; RENAL-CELL CARCINOMA; BEVACIZUMAB THERAPY; BLOOD-FLOW; US; CANCER; SONOGRAPHY; ULTRASONOGRAPHY; QUANTIFICATION; PERFUSION; AGENT;
D O I
10.1007/s10456-012-9271-3
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
To develop and test a real-time motion compensation algorithm for contrast-enhanced ultrasound imaging of tumor angiogenesis on a clinical ultrasound system. The Administrative Institutional Panel on Laboratory Animal Care approved all experiments. A new motion correction algorithm measuring the sum of absolute differences in pixel displacements within a designated tracking box was implemented in a clinical ultrasound machine. In vivo angiogenesis measurements (expressed as percent contrast area) with and without motion compensated maximum intensity persistence (MIP) ultrasound imaging were analyzed in human colon cancer xenografts (n = 64) in mice. Differences in MIP ultrasound imaging signal with and without motion compensation were compared and correlated with displacements in x- and y-directions. The algorithm was tested in an additional twelve colon cancer xenograft-bearing mice with (n = 6) and without (n = 6) anti-vascular therapy (ASA-404). In vivo MIP percent contrast area measurements were quantitatively correlated with ex vivo microvessel density (MVD) analysis. MIP percent contrast area was significantly different (P < 0.001) with and without motion compensation. Differences in percent contrast area correlated significantly (P < 0.001) with x- and y-displacements. MIP percent contrast area measurements were more reproducible with motion compensation (ICC = 0.69) than without (ICC = 0.51) on two consecutive ultrasound scans. Following anti-vascular therapy, motion-compensated MIP percent contrast area significantly (P = 0.03) decreased by 39.4 +/- A 14.6 % compared to non-treated mice and correlated well with ex vivo MVD analysis (Rho = 0.70; P = 0.05). Real-time motion-compensated MIP ultrasound imaging allows reliable and accurate quantification and monitoring of angiogenesis in tumors exposed to breathing-induced motion artifacts.
引用
收藏
页码:433 / 442
页数:10
相关论文
共 50 条
  • [41] Real-time contrast-enhanced holographic imaging using phase coherent photorefractive quantum wells
    Dongol, A.
    Thompson, J.
    Schmitzer, H.
    Tierney, D.
    Wagner, H. P.
    OPTICS EXPRESS, 2015, 23 (10): : 12795 - 12807
  • [42] Assessing tumor angiogenesis in colorectal cancer by quantitative contrast-enhanced endoscopic ultrasound and molecular and immunohistochemical analysis
    Cartana, Elena-Tatiana
    Gheonea, Dan Ionut
    Cherciu, Irina Florina
    Streata, Ioana
    Uscatu, Constantin-Daniel
    Nicoli, Elena-Raluca
    Ioana, Mihai
    Pirici, Daniel
    Georgescu, Claudia-Valentina
    Alexandru, Dragos-Ovidiu
    Surlin, Valeriu
    Gruionu, Gabriel
    Saftoiu, Adrian
    ENDOSCOPIC ULTRASOUND, 2018, 7 (03) : 175 - 183
  • [43] Quantitative contrast-enhanced ultrasound imaging: a review of sources of variability
    Tang, M. -X.
    Mulvana, H.
    Gauthier, T.
    Lim, A. K. P.
    Cosgrove, D. O.
    Eckersley, R. J.
    Stride, E.
    INTERFACE FOCUS, 2011, 1 (04) : 520 - 539
  • [44] Contrast-enhanced ultrasound using real-time contrast harmonic imaging in invasive breast cancer: comparison of enhancement dynamics with three different doses of contrast agent
    Saracco, Ariel
    Szabo, Botond K.
    Aspelin, Peter
    Leifland, Karin
    Tanczos, Ervin
    Wilczek, Brigitte
    Axelsson, Rimma
    ACTA RADIOLOGICA, 2015, 56 (01) : 34 - 41
  • [45] Contrast-enhanced ultrasound improves real-time imaging of ablation region during radiofrequency ablation: Preliminary results
    Wiggermann, P.
    Zuber-Jerger, I.
    Zausig, Y.
    Loss, M.
    Scherer, M. N.
    Schreyer, A. G.
    Stroszczynski, C.
    Jung, E. M.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 49 (1-4) : 43 - 54
  • [46] Comparing Quantitative Immunohistochemical Markers of Angiogenesis to Contrast-Enhanced Subharmonic Imaging
    Gupta, Aditi
    Forsberg, Mark A.
    Dulin, Kelly
    Jaffe, Samantha
    Dave, Jaydev K.
    Halldorsdottir, Valgerdur G.
    Marshall, Andrew
    Forsberg, Anya I.
    Eisenbrey, John R.
    Machado, Priscilla
    Fox, Traci B.
    Liu, Ji-Bin
    Forsberg, Flemming
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (09) : 1839 - 1847
  • [47] Assessment and Monitoring Tumor Vascularity With Contrast-Enhanced Ultrasound Maximum Intensity Persistence Imaging
    Pysz, Marybeth A.
    Foygel, Kira
    Panje, Cedric M.
    Needles, Andrew
    Tian, Lu
    Willmann, Juergen K.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (03) : 187 - 195
  • [48] Contrast-enhanced ultrasound of hepatocellular carcinoma: Correlation of washout time and angiogenesis
    Xia, Y.
    Jiang, Y. X.
    Dai, Q.
    Xiao, Y.
    Lv, K.
    Wang, L.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 48 (04) : 265 - 273
  • [49] Targeted Contrast-Enhanced Ultrasound Imaging of Tumor Angiogenesis with Contrast Microbubbles Conjugated to Integrin-Binding Knottin Peptides
    Willmann, Juergen K.
    Kimura, Richard H.
    Deshpande, Nirupama
    Lutz, Amelie M.
    Cochran, Jennifer R.
    Gambhir, Sanjiv S.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (03) : 433 - 440
  • [50] Contrast-Enhanced Ultrasound Tumor Therapy With Abdominal Imaging Transducer
    Morrison, Ryan G.
    Karmacharya, Mrigendra B.
    Sehgal, Chandra M.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2022, 16 (04):