Modulated active charge exchange fast ion diagnostic for the C-2 field-reversed configuration experiment

被引:6
|
作者
Korepanov, S. [1 ]
Smirnov, A. [1 ]
Clary, R. [1 ]
Dettrick, S. [1 ]
Deichuli, P. [2 ]
Kondakov, A. [2 ]
Murakhtin, S. [2 ]
机构
[1] Tri Alpha Energy Inc, Rancho Santa Margarita, CA 92688 USA
[2] Budker Inst Nucl Phys, Novosibirsk 630090, Russia
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2012年 / 83卷 / 10期
关键词
PLATE ELECTROSTATIC SPECTROGRAPH;
D O I
10.1063/1.4732853
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A diagnostic technique for measuring the fast-ion energy distribution in a field-reversed configuration plasma was developed and tested on the C-2 experiment. A deuterium neutral beam modulated at 22 kHz is injected into the plasma, producing a localized charge-exchange target for the confined fast protons. The escaping fast neutrals are detected by a neutral particle analyzer. The target beam transverse size (similar to 15 cm) defines the spatial resolution of the method. The equivalent current density of the target beam is <= 0.15 A/cm(2), which corresponds to a neutral density (similar to 6 x 10(9) cm(-3)) that highly exceeds the background neutral density in the core of C-2. The deuterium fast-ions due to the target beam (E similar to 27 keV), are not confined in C-2 and thus make a negligible contribution to the measured signals. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4732853]
引用
收藏
页数:3
相关论文
共 49 条
  • [41] Calibration and applications of visible imaging cameras on the C-2U advanced beam-driven field-reversed configuration device
    Granstedt, E. M.
    Fallah, D.
    Thompson, M. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [42] Interpreting ion-energy distributions using charge exchange emitted from deeply kinetic field-reversed-configuration plasmas
    Glasser, A. H.
    Cohen, S. A.
    PHYSICS OF PLASMAS, 2022, 29 (05)
  • [43] Achievement of field-reversed configuration plasma sustainment via 10 MW neutral-beam injection on the C-2U device
    Gota, H.
    Binderbauer, M. W.
    Tajima, T.
    Putvinski, S.
    Tuszewski, M.
    Dettrick, S.
    Garate, E.
    Korepanov, S.
    Smirnov, A.
    Thompson, M. C.
    Trask, E.
    Yang, X.
    Schmitz, L.
    Lin, Z.
    Ivanov, A. A.
    Asai, T.
    Allfrey, I.
    Andow, R.
    Beall, M.
    Bolte, N.
    Bui, D. Q.
    Cappello, M.
    Ceccherini, F.
    Clary, R.
    Cheung, A. H.
    Conroy, K.
    Deng, B. H.
    Douglass, J.
    Dunaevsky, A.
    Feng, P.
    Fulton, D.
    Galeotti, L.
    Granstedt, E.
    Griswold, M.
    Gupta, D.
    Gupta, S.
    Hubbard, K.
    Isakov, I.
    Kinley, J. S.
    Knapp, K.
    Magee, R.
    Matvienko, V.
    Mendoza, R.
    Mok, Y.
    Necas, A.
    Primavera, S.
    Onofri, M.
    Osin, D.
    Rath, N.
    Roche, T.
    NUCLEAR FUSION, 2017, 57 (11)
  • [44] High sensitivity far infrared laser diagnostics for the C-2U advanced beam-driven field-reversed configuration plasmas
    Deng, B. H.
    Beall, M.
    Schroeder, J.
    Settles, G.
    Feng, P.
    Kinley, J. S.
    Gota, H.
    Thompson, M. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [45] Active fast ion charge exchange measurements using a neutral particle analyzer and multiple beam species in C-2W
    Kamio, S.
    Granstedt, E. M.
    Clary, R.
    Player, G.
    Korepanov, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (10):
  • [46] Measurements of impurity ion temperature and velocity distributions via active charge-exchange recombination spectroscopy in C-2W
    Nations, M.
    Gupta, D.
    Sweeney, J.
    Frausto, L.
    Tobin, M.
    Team, Tae
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (05):
  • [47] First time-resolved electron density measurements in the C-2W advanced field-reversed configuration plasmas from long-path compact second-harmonic interferometer
    Beall, M.
    Sheftman, D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [48] Measurements of impurity ion temperature and velocity distributions via active charge-exchange recombination spectroscopy in C-2W (vol 92, 053512, 2021)
    Nations, M.
    Gupta, D.
    Sweeney, J.
    Frausto, L.
    Tobin, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (06):
  • [49] Erratum: Measurements of impurity ion temperature and velocity distributions via active charge-exchange recombination spectroscopy in C-2W (Review of Scientific Instruments (2021) 92 (053512) DOI: 10.1063/5.0043838)
    TAE Technologies, Rancho Santa Margarita
    CA
    92688, United States
    Rev. Sci. Instrum., 1600, 6