Effect of core design on fracture resistance of zirconia-lithium disilicate anterior bilayered crowns

被引:1
|
作者
Ko, Kyung-Ho
Park, Chan-Jin
Cho, Lee-Ra
Huh, Yoon-Hyuk
机构
[1] Gangneung Wonju Natl Univ, Coll Dent, Dept Prosthodont, Kangnung, South Korea
[2] Gangneung Wonju Natl Univ, Coll Dent, Res Inst Oral Sci, Kangnung, South Korea
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2020年 / 12卷 / 04期
基金
新加坡国家研究基金会;
关键词
Lithium disilicate; Zirconia; Metal-ceramic crown; Fracture resistance; FIXED DENTAL PROSTHESES; METAL; STRENGTH; TRANSLUCENCY; THICKNESS; STABILITY; STUDENTS; LINER;
D O I
10.4047/jap.2020.12.4.181
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The effect of core design on the fracture resistance of zirconia-lithium disilicate (LS2) bilayered crowns for anterior teeth is evaluated by comparing with that of metal-ceramic crowns. MATERIALS AND METHODS. Forty customized titanium abutments for maxillary central incisor were prepared. Each group of 10 units was constructed using the same veneer form of designs A and B, which covered labial surface to approximately one third of the incisal and cervical palatal surface, respectively. 1.52 pressed-on-zirconia (POZ) and porcelain-fused-to-metal (PFM) crowns were divided into "POZ_A," "POZ_B," "PFM_A," and "PFM_B" groups, and 6000 thermal cycles (5/55 degrees C) were performed after 24 h storage in distilled water at 37 degrees C. All specimens were prepared using a single type of self-adhesive resin cement. The fracture resistance was measured using a universal testing machine. Failure mode and elemental analyses of the bonding interface were performed. The data were analyzed using Welch's t-test and the Games-Howell exact test. RESULTS. The PFM_B (1376.8 +/- 93.3 N) group demonstrated significantly higher fracture strength than the PFM_A (915.8 +/- 206.3 N) and POZ_B (963.8 +/- 316.2 N) groups (P<.05). There was no statistically significant difference in fracture resistance between the POZ_A (1184.4 +/- .319.6 N) and POZ_B groups (P>.05). Regardless of the design differences of the zirconia cores, fractures involving cores occurred in all specimens of the POZ groups. CONCLUSION. The bilayered anterior POZ crowns showed different fracture resistance arid fracture pattern according to the core design compared to PFM.
引用
收藏
页码:181 / 188
页数:8
相关论文
共 50 条
  • [21] Effect of Cervical Collar Removal on the Fracture Load of Anterior Zirconia Crowns
    Campos, Fernanda
    Cardoso, Mayra
    de Melo, Renata Marques
    Bottino, Marco Antonio
    Souza, Rodrigo O. A.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2017, 37 (02) : 241 - +
  • [22] The effect of preparation taper on the resistance to fracture of monolithic zirconia crowns
    Schriwer, Christian
    Gjerdet, Nils Roar
    Arola, Dwayne
    Oilo, Marit
    DENTAL MATERIALS, 2021, 37 (08) : E427 - E434
  • [23] Effect of core ceramic grinding on fracture behaviour of bilayered lithium disilicate glass-ceramic under two loading schemes
    Wang, Xiao-Dong
    Jian, Yu-Tao
    Guess, Petra C.
    Swain, Michael V.
    Zhang, Xin-Ping
    Zhao, Ke
    JOURNAL OF DENTISTRY, 2014, 42 (11) : 1436 - 1445
  • [24] Influence of zirconia abutment preparation on the fracture strength of single implant lithium disilicate crowns after chewing simulation
    Mitsias, Miltiadis
    Koutayas, Spiridon-Oumvertos
    Wolfart, Stefan
    Kern, Matthias
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (06) : 675 - 682
  • [25] Comparison of Fracture Resistance for Chairside CAD/CAM Lithium Disilicate Crowns and Overlays with Different Designs
    Jurado, Carlos Alberto
    Kaleinikova, Zinaida
    Tsujimoto, Akimasa
    Trevino, Daniel Alberto Cortes
    Seghi, Robert R.
    Lee, Damian J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (04): : 341 - 347
  • [26] Does Preheating Resin Cements Affect Fracture Resistance of Lithium Disilicate and Zirconia Restorations?
    Sakrana, Amal Abdelsamad
    Al-Zordk, Walid
    El-Sebaey, Heba
    Elsherbini, Ahmed
    Ozcan, Mutlu
    MATERIALS, 2021, 14 (19)
  • [27] Fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in- vitro study)
    Fayed, Amro Khalil
    Azer, Amir Shoukry
    Aboelhassan, Rewaa Gaber
    BMC ORAL HEALTH, 2025, 25 (01):
  • [28] Effect of total occlusal convergence on fit and fracture resistance of zirconia-reinforced lithium silicate crowns
    Alammari, Manal Rahma
    Abdelnabi, Mohamed Hussein
    Swelem, Amal Ali
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2019, 11 : 1 - 8
  • [29] Effect of Core Thickness Differences on Post-Fatigue Indentation Fracture Resistance of Veneered Zirconia Crowns
    Alhasanyah, Abdulrahman
    Vaidyanathan, Tritala K.
    Flinton, Robert J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (05): : 383 - 390
  • [30] Effect of surface pretreatment and artificial aging on the retention of lithium disilicate crowns cemented to zirconia implant abutments
    Reary, Juston A.
    Katsavochristou, Anastasia
    Powers, John M.
    Kiat-amnuay, Sudarat
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03): : 459 - 467