Ac-dc current transfer step-up calibration and uncertainty calculation

被引:0
|
作者
Klonz, M [1 ]
Laiz, H [1 ]
Spiegel, T [1 ]
Bittel, P [1 ]
机构
[1] PTB, D-38116 Braunschweig, Germany
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
New ac-de current transfer standards are built for the current range from 0.3 mA to 20 A and the frequency range from 10 Hz to 100 kHz. A 3-dimensional PTB-Multijunction Thermal Converter (MJTC) with a heater resistance of 27 Omega is the basic standard for the ac-dc current transfer at currents from 20 mA to 50 mA. At lower currents, planar MJTCs (PMJTCs) with heater resistances from 90 Omega to 960 Omega are used in a step-down procedure. Coaxial current shunts in parallel with PMJTCs extend the current range up to 20 A. The standard measurement uncertainties are in the range from 0.2 muA/A at 25 mA and 1 kHz to 50 muA/A at 20 A and 100 kHz. The high sensitivity of the PMJTC allows bigger steps in the step-up calibration and some smaller steps between these steps. Calibration of all these steps leads to an overdetermined system to check for the validity of the assumptions made in the step-up procedure. This results in reduced uncertainties at the different current levels compared to the old method.
引用
收藏
页码:1435 / 1440
页数:4
相关论文
共 50 条
  • [21] A precision coaxial current shunt for current AC-DC transfer
    Malinowski, Maciej
    Kubiczek, Krzysztof
    Kampik, Marian
    MEASUREMENT, 2021, 176
  • [22] Calibration of a low-voltage AC-DC transfer standard
    Filipski, PS
    Rinfret, RL
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (05) : 1067 - 1071
  • [23] Calibration of a low-voltage AC-DC transfer standard
    Natl Research Council Canada, Ottawa, Canada
    IEEE Trans Instrum Meas, 5 (1067-1071):
  • [24] Current ac-dc transfer measurements in the microampere range
    Rydler, KE
    Tarasso, V
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 550 - 551
  • [25] Coaxial shunts for the ac-dc transfer standards of current
    Pogliano, U.
    Bosco, G. C.
    Serazio, D.
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 30 - 31
  • [26] Current ac-dc transfer measurements in the microampere range
    Rydler, KE
    Tarasso, V
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) : 342 - 344
  • [27] International comparison of AC-DC current transfer standards
    Heine, G.
    Garcocz, M.
    Waldmann, W.
    METROLOGIA, 2017, 54
  • [28] BCR INTERCOMPARISON OF AC-DC CURRENT TRANSFER STANDARDS
    KLONZ, M
    BERGEEST, R
    CAIZERGUES, A
    FRAISSE, D
    WINTHER, CAD
    POGLIANO, U
    CABIATI, F
    BOSCO, GC
    ZAGO, G
    DESSENS, JT
    DEVREEDE, JPM
    RYDLER, KE
    NILSSON, H
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (02) : 403 - 406
  • [29] CURRENT DEVELOPMENTS IN ACCURATE AC-DC TRANSFER MEASUREMENTS
    KLONZ, M
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (02) : 363 - 366
  • [30] Coaxial Shunts as AC-DC Transfer Standards of Current
    Pogliano, Umberto
    Bosco, Gian Carlo
    Serazio, Danilo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (04) : 872 - 877