Analysis of localized dissipation factor measurements on the insulation system of mechanically aged generator stator bars

被引:0
|
作者
Cimino, Alessandro [1 ]
Foelting, Christian [1 ]
Jenau, Frank [1 ]
Staubach, Christian [2 ]
机构
[1] TU Dortmund Univ, Inst High Voltage Engn, Dortmund, Germany
[2] Siemens AG, Siemens AG Power & Gas, Mulheim, Germany
关键词
generator stator bar; insulation; multifactor aging; cracking; dissipation factor;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Integration of decentralised renewable energy sources lead to an increasingly fluctuating load profile of power engineering equipment. In particular, on large rotating machines this changing load profiles continuously stress the insulation in form of mechanical and thermo-mechanical forces. Eventually, a mechanical overstressing can ultimately result in an electrical breakdown of the insulation. To evaluate the condition of electrical insulation systems the knowledge of predominant aging mechanisms is of particular importance. This paper presents accelerated multi-factor aging tests with simultaneous mechanical and thermal loads on generator stator bars. Localized dissipation factor measurements as well as partial discharge detection are performed between aging cycles. An interrelationship between mechanical stress and the results of experimental examinations is indicated and analyzed. It can be shown, that mechanical stress can lead to cracking of the insulation, which is verified by the use of computer tomography.
引用
收藏
页码:674 / 677
页数:4
相关论文
共 50 条
  • [31] Progress in Development of a Nanocomposite Stator Winding Insulation System for Improved Generator Performance
    Hildinger, Thomas
    Weidner, Juergen R.
    2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 139 - 142
  • [32] Development of a vertical generator stator bar insulation system for operation at increased stress
    Draper, RE
    Moore, BJ
    PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, 1997, : 597 - 602
  • [33] Study on Multi-factor Aging Characteristics of Stator Insulation for Wind Turbine Generator
    Ding Xiaoxia
    Liu Xuezhong
    Zhang Jianjun
    Zhang Tianlong
    Bai Yonggang
    Ren Wene
    2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [34] Stability analysis of passive sensors of insulation dissipation factor
    Gaodianya Jishu/High Voltage Engineering, 1995, 21 (04): : 39 - 41
  • [35] Statistical Assessment of Lifetime Data of Multi-Factor Aged Generator Bars
    Cimino, Alessandro
    Jenau, Frank
    Horst, Joerg
    2019 54TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2019,
  • [36] Improvement of stator slot structure based on insulation stresses analysis in HV generator
    Azizi, Diako
    Gholami, Ahmad
    Abbasi, Vahid
    World Academy of Science, Engineering and Technology, 2010, 68 : 309 - 314
  • [37] Potential and limitation of dielectric response analysis for mechanically aged VPI insulation
    Staubach, Christian
    Meissner, Soeren
    2022 INTERNATIONAL CONFERENCE ON DIAGNOSTICS IN ELECTRICAL ENGINEERING (DIAGNOSTIKA), 2022, : 9 - 12
  • [38] Online Monitoring of Capacitance and Dissipation Factor of Motor Stator Winding Insulation during Accelerated Life Testing
    Zhang, Pinjia
    Neti, Prabhakar
    Younsi, Karim
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 3267 - 3271
  • [39] Long-term Aged Performances of Stator Insulation for Wind Turbine Generator under Repeat Pulse Voltage
    Liu Xuezhong
    Zhao Xiang
    Wang Ying
    Chen Xiaocong
    Li Dandan
    PROCEEDINGS OF 2011 INTERNATIONAL CONFERENCE ON ELECTRICAL INSULATING MATERIALS (ISEIM), 2011, : 105 - 108
  • [40] Analysis of aging characteristics of generator stator insulation based on loss properties of dynamics and dielectric
    Jia, Zhi-Dong
    Hao, Yan-Peng
    Jiang, Xiong-Wei
    Xie, Heng-Kun
    Geng, Rui-Xiang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2000, 20 (11): : 1 - 5