Corneal changes with accommodation using dual Scheimpflug photography

被引:25
|
作者
Siso-Fuertes, Irene [1 ]
Dominguez-Vicent, Alberto [2 ]
del Aguila-Carrasco, Antonio [2 ]
Ferrer-Blasco, Teresa [2 ]
Montes-Mico, Robert [2 ]
机构
[1] Univ Manchester, Fac Life Sci, Manchester, Lancs, England
[2] Univ Valencia, Optometry Res Grp, Opt Dept, Valencia, Spain
来源
基金
欧洲研究理事会;
关键词
WAVE-FRONT ABERRATIONS; ANTERIOR; SHAPE; LENS; CURVATURE; PENTACAM; QUALITY; SEGMENT; EYE;
D O I
10.1016/j.jcrs.2014.08.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess whether corneal parameters and aberrations are affected by accommodation. SETTING: Optics Department, University of Valencia, Valencia, Spain. DESIGN: Prospective cross-sectional study. METHODS: The Galilei G4 dual Scheimpflug device was used to obtain data on the anterior and posterior axial curvatures, total corneal power (TCP), and corneal pachymetry from 3 corneal zones (central: 0.0 up to 4.0 mm; paracentral or mid: 4.0 up to 7.0 mm; peripheral: 7.0 up to 10.0 mm) in young emmetropic eyes in the unaccommodated and 4 accommodated states (from -1.0 to -4.0 diopters [D] in 1.0 D steps). The 2nd-, 3rd-, and 4th-order aberrations as well as the root mean square (RMS) were also determined for the entire cornea at the same accommodative demands. RESULTS: The study evaluated 7 subjects (12 eyes). No significant changes in any measured parameter were found during accommodation for any corneal zone (P>.05). Statistically significant differences were found in the various corneal zones when it was assumed they were constant with accommodation (P <.01). A stable linear trend with accommodation was also found for corneal aberrations, although individual variations existed because of the high standard deviation values. CONCLUSION: Different parameters in various zones of the cornea as well as corneal aberrations were stable during accommodation. (C) 2015 ASCRS and ESCRS
引用
收藏
页码:981 / 989
页数:9
相关论文
共 50 条
  • [21] CORNEAL DENSITOMETRY AFTER CORNEAL COLLAGEN CROSSLINKING IN KERATOCONUS USING DUAL SCHEIMPFLUG ANALYSER AND ITS RELATION TO SUBJECTIVE HAZE
    Bhatt, Uday
    Kaur, Amanpreet
    Malkoum, Therese
    Sayer, Alina
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 : 95 - 95
  • [22] Quantification of glistenings in intraocular lenses using Scheimpflug photography
    Behndig, Anders
    Monestam, Eva
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01): : 14 - 17
  • [23] Scheimpflug Corneal Densitometry Changes After the Intrastromal Corneal Ring Segment Implantation
    Sedaghat, Mohammad-Reza
    Momeni-Moghaddam, Hamed
    Heravian, Javad
    Belin, Michael W.
    Ambrosio, Renato, Jr.
    Gheysari-Alishahi, Tayebe
    Ghavami, Seyyed Hossein
    CORNEA, 2020, 39 (06) : 761 - 768
  • [24] Biometry of phakic intraocular lens using Scheimpflug photography
    Coppens, JE
    van den Berg, TJTP
    Budo, CJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (10): : 1904 - 1914
  • [25] CHANGES IN CORNEAL CURVATURE DURING ACCOMMODATION IN CHICKS
    TROILO, D
    WALLMAN, J
    VISION RESEARCH, 1987, 27 (02) : 241 - 247
  • [26] Repeatability of corneal power and wavefront aberration measurements with a dual-Scheimpflug Placido corneal topographer
    Wang, Li
    Shirayama, Mariko
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (03): : 425 - 430
  • [27] Evaluation of Corneal Parameters with Dual Scheimpflug Imaging in Patients with Systemic Sclerosis
    Gomes, Beatriz Fiuza
    Santhiago, Marcony R.
    Kara-Junior, Newton
    Moraes, Haroldo Vieira, Jr.
    CURRENT EYE RESEARCH, 2018, 43 (04) : 451 - 454
  • [28] Corneal Biomechanical Changes after Crosslinking for Progressive Keratoconus with the Corneal Visualization Scheimpflug Technology
    Steinberg, Johannes
    Katz, Toam
    Mousli, Aiham
    Frings, Andreas
    Casagrande, Maria K.
    Druchkiv, Vasyl
    Richard, Gisbert
    Linke, Stephan J.
    JOURNAL OF OPHTHALMOLOGY, 2014, 2014
  • [29] Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement
    Kawamorita, Takushi
    Uozato, Hiroshi
    Kamiya, Kazutaka
    Bax, Leon
    Tsutsui, Kenta
    Aizawa, Daisuke
    Shimizu, Kimiya
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01): : 127 - 133
  • [30] Intrasubject repeatability of corneal morphology measurements obtained with a new Scheimpflug photography-based system
    Montalban, Raul
    Pinero, David P.
    Javaloy, Jaime
    Alio, Jorge L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06): : 971 - 977