Study on the Over-voltage and Over-current of Grid-connected Inverters in Non-fault Conditions

被引:0
|
作者
Zeng, Zheng [1 ]
Yang, Huan [1 ]
Zhao, Rongxiang [1 ]
Zeng, Zhiyong [1 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Over-voltage and over-current of grid-connected inverters not only affect their grid-connected or isolated operation modes directly, but also relate to the safety of their components. Over-voltage and over-current of grid-connected inverters in non-fault conditions are investigated in this paper. The over-voltage on dc-link and the filter capacitor as well the over-current caused by inrush current of isolation transformer are studied in detail. Simultaneously, their physical mechanisms and mathematical models are established. Furthermore, some response strategies are presented to overcome these over-voltage and over-current processes. At last, based on a typical grid-connected inverter topology, some simulation results are achieved using PSIM and PSCAD/EMTDC. In addition, a prototype is set up and some experimental outcomes are presented. The simulation results and experimental tests have verified the validity and effectiveness of the proposed models and methods.
引用
收藏
页码:1080 / 1085
页数:6
相关论文
共 50 条
  • [41] Improved current controller based on SVPWM for three-phase grid-connected voltage source inverters
    Zeng, QR
    Chang, LC
    2005 IEEE 36TH POWER ELECTRONIC SPECIALISTS CONFERENCE (PESC), VOLS 1-3, 2005, : 2912 - 2917
  • [42] A Novel Low Voltage Ride Through Control Method for Current Source Grid-Connected Photovoltaic Inverters
    Geng, Yiwen
    Yang, Ke
    Lai, Zou
    Zheng, Pengfei
    Liu, Haiwei
    Deng, Renxiong
    IEEE ACCESS, 2019, 7 : 51735 - 51748
  • [43] Early warning of fault conditions of an over-current protection module in dependable communication applications
    Novak, F
    Zarnik, MS
    Macek, S
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2004, 84 (02) : 125 - 128
  • [44] An Enhanced Current Controller for Grid-Connected Inverters based on Capacitor Current Feedback Active Damping and Capacitor Voltage Decoupling
    dos Santos Serra, Amiron Wolff
    de Souza Ribeiro, Luiz Antonio
    de Matos, Jose Gomes
    2023 25TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, EPE'23 ECCE EUROPE, 2023,
  • [45] Transient Over-Voltages in High Voltage Grid-Connected PV Solar Interconnection
    Zhang, Yi
    Mensah-Bonsu, Chris
    Walke, Pranil
    Arora, Sandeep
    Pierce, Jazmin
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [46] Fault diagnosis for multiple current sensors in grid-connected inverter based on average modulation voltage
    Zhang, Fan
    Zhang, Zhiwei
    Jin, Guangfeng
    Wang, Tianzhen
    Han, Jingang
    Razik, Hubert
    Wang, Yide
    IET POWER ELECTRONICS, 2024, 17 (01) : 54 - 66
  • [47] Influence On Power Frequency Over-voltage By Employing Series Resonance Type Fault Current Limiter
    Hong Jianshan
    Guan Yonggang
    Xu Guozheng
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3484 - 3487
  • [48] Virtual Impedance-Based Active Damping for LCL Resonance in Grid-Connected Voltage Source Inverters with Grid Current Feedback
    Liu, Teng
    Liu, Zeng
    Liu, Jinjun
    Liu, Zipeng
    2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [49] Control Strategy to Eliminate Impact of Voltage Measurement Errors on Grid Current Performance of Three-Phase Grid-Connected Inverters
    Quoc-Nam Trinh
    Choo, Fook Hoong
    Wang, Peng
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (09) : 7508 - 7519
  • [50] Leakage Current Suppression With Capacitor Voltage Control of Three-Level Flying Capacitor Grid-Connected Inverters
    Zhao, Xuan
    Jiang, Dong
    Chen, Jianan
    Shen, Zewei
    Li, Qiao
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (03) : 2191 - 2201