The Impact of Fiberwire, Fiberloop, and Locking Suture Configuration on Flexor Tendon Repairs

被引:13
|
作者
Haimovici, Ludmila [1 ]
Papafragkou, Sotirios [1 ]
Lee, Wei
Dagum, Alexander [2 ]
Hurst, Lawrence C. [3 ]
机构
[1] Univ Med & Dent New Jersey, Dept Orthopaed, Newark, NJ 07103 USA
[2] SUNY Stony Brook, Div Plast Surg, Stony Brook, NY 11794 USA
[3] SUNY Stony Brook, Dept Orthopaed, Stony Brook, NY 11794 USA
关键词
Fiberwire; Pennington; Fiberloop; BIOMECHANICAL ANALYSIS; MOBILIZATION; LOOPS;
D O I
10.1097/SAP.0b013e31824a212a
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Suture technique, suture material, and the number of strands all play critical roles in achieving optimal strength of flexor tendon repairs. We evaluated the contribution to the tensile strength of flexor tendon repair using the strongest suture material, Fiberwire, and the best surgical technique (locking configuration) using 2- and 4-strand core repair to see what factor played the most important role in tendon repair. Methods: Human cadaver flexor tendons were harvested and repaired in a randomized fashion using locking configuration as derived from Pennington's report. Ten tendons per group were repaired using either 4-0 Fiberloop, 4-0 Fiberwire, or 2-0 Fiberwire. During load-to-failure testing, visible gap force and maximum tensile strength were statistically analyzed. Results: All flexor tendon repairs failed by suture pullout. The 4-strand 4-0 Fiberwire double-Pennington repair was found to be significantly stronger than the 4-strand 4-0 Fiberloop single-Pennington repair. When the 2-strand repair (2-0 Fiberwire) was compared to the 4-strand single-Pennington repair (4-0 Fiberloop), there was no significant difference found. Conclusions: The suture strand configuration rather than the strict number of strands or the strength of the suture material yielded the maximum tensile strength with reduced gapping at the repair site.
引用
收藏
页码:468 / 470
页数:3
相关论文
共 50 条
  • [21] SPLINT MODIFICATION FOR FLEXOR TENDON REPAIRS
    LOPEZ, MS
    HANLEY, KF
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 1984, 38 (06): : 398 - 403
  • [22] COMPARATIVE MECHANICAL ANALYSIS OF DORSAL VERSUS PALMAR PLACEMENT OF CORE SUTURE FOR FLEXOR TENDON REPAIRS
    SOEJIMA, O
    DIAO, E
    LOTZ, JC
    HARIHARAN, JS
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (05): : 801 - 807
  • [23] The Effect of Suture Materials on the Biomechanical Performance of Different Flexor Tendon Repairs and the Concept of Construct Efficiency
    Rung, Yoke Wong
    Loke, Austin Mun Kitt
    Tay, Shian Chao
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2018, 23 (02): : 243 - 247
  • [24] LOCKING LOOP TENDON SUTURE
    PENNINGTON, DG
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1979, 63 (05) : 648 - 652
  • [25] The Impact of Suture Caliber and Looped Configurations on the Suture-Tendon Interface in Zone II Flexor Tendon Repair
    Bernstein, Derek T.
    Alexander, Jamie J.
    Petersen, Nancy J.
    Lambert, Bradley S.
    Noble, Philip C.
    Netscher, David T.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (02): : 156.e1 - 156.e8
  • [26] Locking loops for flexor tendon repair
    Lawrence, TM
    Davis, TRC
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2005, 87 (05) : 385 - 386
  • [27] Successful suture of finger flexor tendon
    Jones, RM
    LANCET, 1944, 2 : 111 - 111
  • [28] Negative Predictors of Outcomes of Flexor Tendon Repairs
    Hurley, C. M.
    Reilly, Frank
    Callaghan, Simon
    Baig, M. N.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (03)
  • [29] HISTORICAL DEVELOPMENT OF THE FLEXOR TENDON SUTURE
    KUNZE, K
    MEDIZINISCHE WELT, 1987, 38 (46): : 1519 - 1529
  • [30] Recent evolutions in flexor tendon repairs and rehabilitation
    Tang, Jin Bo
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (05) : 469 - 473