A New Single Ended Fault Location Method for Transmission Line Based on Positive Sequence Superimposed Network During Auto-Reclosing

被引:46
|
作者
Ji, Liang [1 ]
Tao, Xiaojie [1 ]
Fu, Yang [1 ]
Fu, Yong [2 ]
Mi, Yang [1 ]
Li, Zhenkun [1 ]
机构
[1] Shanghai Univ Elect Power, Dept Elect Power Engn, Shanghai 200090, Peoples R China
[2] Mississippi State Univ, Dept Elect & Comp Engn, Starkville, MS 39762 USA
关键词
Auto-reclosing operation scheme; fault location; power system protection; ALGORITHM; INTERIOR; VOLTAGE;
D O I
10.1109/TPWRD.2019.2901835
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new single ended fault location method for transmission line based on positive sequence superimposed network during auto-reclosing. The proposed method only requires local measurement data and can not only eliminate but also quantify the negative effects of fault resistance, fault distance, and unknown remote end source impedance, which are marked as the most challenging problems in single ended fault location algorithms. In this paper, by analyzing the operation of auto-reclosing, the transmission line model using positive sequence superimposed network during both fault time section and reclosing time section has been developed to establish the system equations regarding fault position and local measurement data of each discrete time section. In order to retrieve converged and accurate fault location from resulting nonlinear equations, the trust-region reflective algorithm is applied in this paper. Various case studies and evaluations based on EMTP/ATP and RTDS simulations have been carried out to illustrate the effectiveness of the proposed method. The proposed new fault location method is also potentially economical as it can be relatively straightforward to implement in the standard protection hardware platform.
引用
收藏
页码:1019 / 1029
页数:11
相关论文
共 50 条
  • [41] Novel principle of single-ended line fault location technique for EHV transmission systems
    Ha, Heng-Xu
    Zhang, Bao-Hui
    Lu, Zhi-Lai
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2003, 23 (02): : 42 - 45
  • [42] Single-ended data based fault location method for multi-branch distribution network
    Wang, Zixuan
    Ma, Xiao
    Lu, Yi
    Wang, Chaoliang
    Lin, Xiangning
    Sui, Quan
    ENERGY REPORTS, 2020, 6 : 385 - 390
  • [43] New Principle of Single-Ended Fault Location Base on Verification for Transmission lines
    Yu Jiangtao
    Jiao Yanjun
    Wang Zengping
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [44] A continuous wavelet and fast fourier transform-based single-phase adaptive auto-reclosing scheme for ehv transmission lines
    Khan, Waqar Ahmad
    Rehman, Bilawal
    ur Rehman, Atiq
    Nasir, Mashood
    Abid, Muhammad Irfan
    ELECTRICAL ENGINEERING, 2023, 105 (03) : 1347 - 1361
  • [45] A continuous wavelet and fast fourier transform-based single-phase adaptive auto-reclosing scheme for ehv transmission lines
    Waqar Ahmad Khan
    Bilawal Rehman
    Atiq ur Rehman
    Mashood Nasir
    Muhammad Irfan Abid
    Electrical Engineering, 2023, 105 : 1347 - 1361
  • [47] Anti-interference adaptive single-phase auto-reclosing schemes based on reactive power characteristics for transmission lines with shunt reactors
    Xie, Chao
    Li, Fengting
    Wang, Bin
    Fan, Yanfang
    Jing, Liuming
    Chen, Weiwei
    Wang, Cong
    ELECTRIC POWER SYSTEMS RESEARCH, 2019, 170 : 176 - 183
  • [48] Study on New Method for Distributed Fault Location of Overhead Transmission Line
    Liu, Yadong
    Sheng, Gehao
    He, Zhimin
    Jiang, Xiuchen
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [49] Single-ended multi-method phasor-based approach for optimized fault location on transmission lines
    Lopes, Felipe, V
    Leite Jr, Eduardo Jorge S.
    Ribeiro, Joao Paulo G.
    Piardi, Artur B.
    Scheid, Allan, V
    Zat, Guilherme
    Espinoza, Renzo G. F.
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 212
  • [50] New fault-location method for a single multiterminal transmission line using synchronized phasor measurements
    Brahma, Sukumar M.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) : 1148 - 1153