STEAM TURBINE VALVE TESTING, INSPECTION AND MAINTENANCE TO AVOID TURBINE OVERSPEED EVENTS

被引:0
|
作者
Mutama, Kuda R. [1 ]
机构
[1] TS Power Plant, Battle Mt, NV 89820 USA
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Steam turbine valves are the most important components before a steam turbine for the admission and control of steam flow. Steam turbine valve configurations can be all in one body or as individual valves for the large units, for the main stop (throttle) and control functions for each section of the steam turbine. Today's thermal power plants for drum or once-through type supercritical boilers produce very high temperature steam in the final superheat and reheat section of 1055 degrees F or higher requiring special boiler tube metal alloys, some of which are subject to steam oxidation as in austenitic steels. The oxidation material is mainly in the form of iron oxide or magnetite which is subject to exfoliation. The exfoliated oxide material is carried over to the steam turbine valves and to the high and intermediate pressure turbines. The effect of exfoliated oxide material in valve and turbine components is to cause solid particle erosion (SPE) and therefore shortening the life of those parts due to damage. As time goes by if valves are not tested and do not meet their inspection and maintenance schedule they will build up oxidation material to form scale material called blue blush and eventually they stick and will, not shut properly.
引用
收藏
页码:507 / 514
页数:8
相关论文
共 50 条
  • [41] In-service inspection and defect assessment of steam turbine rotors
    MAN Energie GmbH, Nuremberg, Germany
    Int J Pressure Vessels Piping, 1-3 (281-292):
  • [42] In-service inspection and defect assessment of steam turbine rotors
    Mayer, KH
    Prestel, W
    Weber, D
    Weiss, M
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 1996, 66 (1-3) : 281 - 292
  • [43] REMOTE IN-SERVICE INSPECTION OF STEAM-TURBINE BLADES
    PORTER, J
    MATERIALS EVALUATION, 1984, 42 (04) : A4 - A4
  • [44] Inspection of the steam turbine at Kiel municipal power station, associated with the replacement of the HP stage turbine blading
    Michels, B.
    VGB Kraftwerkstechnik, 1997, 77 (09): : 713 - 718
  • [45] INSPECTION AND MAINTENANCE OF GAS-TURBINE NOZZLES, BUCKETS AND ROTORS
    DUBOIS, MR
    FRESNEDA, RJ
    POWER ENGINEERING, 1978, 82 (07) : 58 - 61
  • [46] WIND-TURBINE INSPECTION, MAINTENANCE AND REPAIR ROBOTIC SYSTEM
    Cieslak, Chris
    Shah, Aksat
    Clark, Brodie
    Childs, Peter
    PROCEEDINGS OF ASME TURBO EXPO 2023: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2023, VOL 14, 2023,
  • [47] Field validation testing of new heat™ steam turbine
    Miller, Richard J., Jr.
    Conner, Reginald D.
    Proceedings of the ASME Power Conference, 2006, : 367 - 376
  • [48] Performance testing on a 11000 kW Zoelly steam turbine
    Stodola, A
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1927, 71 : 747 - 752
  • [49] Performance guarantee and testing of steam turbine retrofits.
    Kearney, PJ
    Hogg, SI
    Brown, RD
    PROCEEDINGS OF 2004 ASME POWER, 2004, : 315 - 324
  • [50] Steam Turbine Blade MMM Testing and Failure Analysis
    Xing, Haiyan
    Wu, Dabo
    Zhang, Lihong
    Xu, Minqiang
    MANUFACTURING ENGINEERING AND AUTOMATION I, PTS 1-3, 2011, 139-141 : 2561 - +