Objective assessment of deformable image registration in radiotherapy: A multi-institution study

被引:120
|
作者
Kashani, Rojano [1 ]
Hub, Martina [2 ]
Balter, James M. [1 ]
Kessler, Marc L. [1 ]
Dong, Lei [3 ]
Zhang, Lifei [3 ]
Xing, Lei [4 ]
Xie, Yaoqin [4 ]
Hawkes, David [5 ]
Schnabel, Julia A. [5 ]
McClelland, Jamie [5 ]
Joshi, Sarang [6 ]
Chen, Quan [7 ]
Lu, Weiguo [7 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[2] Deutsch Krebsforschungszentrum, Dept Radiat Oncol, D-6900 Heidelberg, Germany
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[4] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
[5] UCL, Ctr Med Image Comp, London, England
[6] Univ Utah, Sci Comp & Imaging Inst, Salt Lake City, UT 84112 USA
[7] TomoTherapy Inc, Madison, WI 53717 USA
关键词
computerised tomography; image registration; medical image processing; phantoms; radiation therapy;
D O I
10.1118/1.3013563
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Previous studies in this area are based on the ability of alignment to reproduce analytically generated deformations applied to sample image data, or use of contours or bifurcations as ground truth for evaluation of alignment accuracy. In this study, a deformable phantom was embedded with 48 small plastic markers, placed in regions varying from high contrast to roughly uniform regional intensity, and small to large regional discontinuities in movement. CT volumes of this phantom were acquired at different deformation states. After manual localization of marker coordinates, images were edited to remove the markers. The resulting image volumes were sent to five collaborating institutions, each of which has developed previously published deformable alignment tools routinely in use. Alignments were done, and applied to the list of reference coordinates at the inhale state. The transformed coordinates were compared to the actual marker locations at exhale. A total of eight alignment techniques were tested from the six institutions. All algorithms performed generally well, as compared to previous publications. Average errors in predicted location ranged from 1.5 to 3.9 mm, depending on technique. No algorithm was uniformly accurate across all regions of the phantom, with maximum errors ranging from 5.1 to 15.4 mm. Larger errors were seen in regions near significant shape changes, as well as areas with uniform contrast but large local motion discontinuity. Although reasonable accuracy was achieved overall, the variation of error in different regions suggests caution in globally accepting the results from deformable alignment.
引用
收藏
页码:5944 / 5953
页数:10
相关论文
共 50 条
  • [1] Objective assessment of deformable image registration in radiotherapy - a multi-institution study
    Kashani, R.
    Baiter, J.
    Kessler, M.
    Hub, M.
    Dong, L.
    Zhang, L.
    Xing, L.
    Xie, Y.
    Hawkes, D.
    Schnabel, J.
    McClelland, J.
    Joshi, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2545 - 2545
  • [2] A multi-institution deformable registration accuracy study
    Brock, K. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S44 - S44
  • [3] RESULTS OF A MULTI-INSTITUTION DEFORMABLE REGISTRATION ACCURACY STUDY (MIDRAS)
    Brock, Kristy K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (02): : 583 - 596
  • [4] A multi-institution evaluation of deformable image registration algorithms for automatic organ delineation in adaptive head and neck radiotherapy
    Hardcastle, Nicholas
    Tome, Wolfgang A.
    Cannon, Donald M.
    Brouwer, Charlotte L.
    Wittendorp, Paul W. H.
    Dogan, Nesrin
    Guckenberger, Matthias
    Allaire, Stephane
    Mallya, Yogish
    Kumar, Prashant
    Oechsner, Markus
    Richter, Anne
    Song, Shiyu
    Myers, Michael
    Polat, Buelent
    Bzdusek, Karl
    RADIATION ONCOLOGY, 2012, 7
  • [5] A multi-institution evaluation of deformable image registration algorithms for automatic organ delineation in adaptive head and neck radiotherapy
    Nicholas Hardcastle
    Wolfgang A Tomé
    Donald M Cannon
    Charlotte L Brouwer
    Paul WH Wittendorp
    Nesrin Dogan
    Matthias Guckenberger
    Stéphane Allaire
    Yogish Mallya
    Prashant Kumar
    Markus Oechsner
    Anne Richter
    Shiyu Song
    Michael Myers
    Bülent Polat
    Karl Bzdusek
    Radiation Oncology, 7
  • [6] Variability in commercially available deformable image registration: A multi-institution analysis using virtual head and neck phantoms
    Kubli, Alex
    Pukala, Jason
    Shah, Amish P.
    Kelly, Patrick
    Langen, Katja M.
    Bova, Frank J.
    Manon, Rafael R.
    Meeks, Sanford L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (05): : 89 - 96
  • [7] Results From a Multi Institution Study On Image Quality Impact in Deformable Image Registration
    Loi, G.
    Fusella, M.
    Lanzi, E.
    Fiandra, C.
    Orlani, G.
    Lucio, F.
    Strolin, S.
    Gino, E.
    Mezzenga, E.
    Roggio, A.
    Cagni, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3778 - 3778
  • [8] Objective Assessment of the Quality and Accuracy of Deformable Image Registration
    Jurkovic, Ines-Ana
    Papanikolaou, Nikos
    Stathakis, Sotirios
    Kirby, Neil
    Mavroidis, Panayiotis
    JOURNAL OF MEDICAL PHYSICS, 2020, 45 (03) : 156 - 167
  • [9] Multi-objective optimization for deformable image registration: proof of concept
    Alderliesten, Tanja
    Sonke, Jan-Jakob
    Bosman, Peter A. N.
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [10] SALG and POGIL: A multi-institution assessment
    Bressette, Andrew R.
    Simons, Emily
    Straumanis, Andrei
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231