Analysis of Maladjustment Sensitivity and Calibration Method for A Positive-Branch Confocal Unstable Resonator

被引:0
|
作者
Xiang Zhang [1 ]
机构
[1] Chengdu Univ Informat Technol, Dept Optoelect Technol, Chengdu 610225, Peoples R China
来源
关键词
laser optics; confocal unstable resonators; maladjustment analysis; wavefront sensor and measurement; Zernike aberration;
D O I
10.4028/www.scientific.net/AMR.301-303.1351
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The effect of intracavity aberration perturbation on output mode structure properties of unstable laser resonator is been experimentally researched using Hartmann-Shack wavefront sensor on the basis of numerical analysis. Results show that intracavity tilt aberration notablely affects outcoupled intensity distribution, but only a small intracavity tilt perturbation will not obviously augment the high-order aberrations of beam phase properties. The tilt aberration, coma aberration and astigmatism will all be brought, and also tilt aberration is the main component when intracavity mirrors have a vertical movement along the direction of optic axis. When adaptive optical elements such as deformable mirrors are adopted for intracavity aberration correction, the correction for tilt aberration should be considered firstly.
引用
收藏
页码:1351 / 1355
页数:5
相关论文
共 47 条
  • [31] The experimental study of adjustment method for a confocal unstable resonator based on Hartmann-Shack wavefront sensor
    Zhang, Xiang
    Xu, Bing
    Yang, Wei
    Guangxue Jishu/Optical Technique, 2007, 33 (03): : 398 - 402
  • [32] A SENSITIVITY ANALYSIS BASED METHOD FOR ROBOT CALIBRATION
    KAIZERMAN, S
    ZAK, G
    BENHABIB, B
    FENTON, RG
    JOURNAL OF MECHANICAL DESIGN, 1994, 116 (02) : 607 - 613
  • [33] Sensitivity analysis based method for robot calibration
    Kaizerman, S.
    Zak, G.
    Benhabib, B.
    Fenton, R.G.
    Journal of Mechanical Design, Transactions Of the ASME, 1994, 116 (02): : 607 - 613
  • [34] USING THE THEORY OF DESIGN OF EXPERIMENT AND THE SENSITIVITY ANALYSIS METHOD IN SIMULATION OF A GYROSCOPE RESONATOR
    Shevchenko, S. A.
    Melnikov, B. E.
    ST PETERSBURG POLYTECHNIC UNIVERSITY JOURNAL-PHYSICS AND MATHEMATICS, 2023, 16 (01): : 152 - 162
  • [35] Analysis of lasing in COILs with positive and negative branch unstable resonators using a simple geometrical-optics model
    Barmashenko, Boris D.
    XVII INTERNATIONAL SYMPOSIUM ON GAS FLOW, CHEMICAL LASERS, AND HIGH-POWER LASERS, 2009, 7131
  • [36] Differential evolution with sensitivity analysis and the Powell's method for crowd model calibration
    Zhong, Jinghui
    Cai, Wentong
    JOURNAL OF COMPUTATIONAL SCIENCE, 2015, 9 : 26 - 32
  • [37] Sampling Design of Hydraulic and Quality Model Calibration Based on a Global Sensitivity Analysis Method
    Moghaddam, Vahid Abbasi
    Tabesh, Massoud
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2021, 147 (07)
  • [38] Parameters optimization of WOFOST model by integration of global sensitivity analysis and Bayesian calibration method
    He L.
    Hou Y.
    Zhao G.
    Wu D.
    Yu Q.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2016, 32 (02): : 169 - 179
  • [39] Sensitivity analysis of a geometric calibration method using projection matrices for digital tomosynthesis systems
    Li, Xinhua
    Zhang, Da
    Liu, Bob
    MEDICAL PHYSICS, 2011, 38 (01) : 202 - 209
  • [40] A calibration method for non-positive definite covariance matrix in multivariate data analysis
    Huang, Chao
    Farewell, Daniel
    Pan, Jianxin
    JOURNAL OF MULTIVARIATE ANALYSIS, 2017, 157 : 45 - 52