Sugar-metabolism-triggered pathogenic bacteria identification based on pH-sensitive fluorescent carbon dots

被引:20
|
作者
Zhao, Minyang [1 ]
Gao, Xia [1 ]
Tao, Zhanhui [1 ]
Wang, Xinke [1 ]
Lin, Xiaodong [1 ]
Wang, Shuo [2 ]
Liu, Yaqing [1 ,3 ]
机构
[1] Tianjin Univ Sci & Technol, Coll Food Sci & Engn, State Key Lab Food Nutr & Safety, Tianjin 300457, Peoples R China
[2] Nankai Univ, Sch Med, Tianjin Key Lab Food Sci & Hlth, Tianjin 300071, Peoples R China
[3] Beijing Technol & Business Univ, Beijing Adv Innovat Ctr Food Nutr & Human Hlth, Beijing 100048, Peoples R China
基金
中国国家自然科学基金;
关键词
fluorescence; p-CDs; sugar metabolism; bacteria identification; BETA-GALACTOSIDASE; ESCHERICHIA-COLI; STAPHYLOCOCCUS-AUREUS; BIOSENSORS; APTAMER; LACTOSE;
D O I
10.1016/j.snb.2020.128063
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid distinguishing of Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) with high sensitivity is critical for human health. Herein, a smart sugar-metabolism-triggered E. coli and S. aureus identification strategy is established on the basis of pH-sensitive fluorescent carbon dots (p-CDs). The fluorescence of the prepared pCDs depends linearly on the solution pH in the acidic range from 4.0 to 7.0. When p-CDs are introduced into aqueous solutions that contain bacteria and sugar molecules, such as glucose or lactose, the fluorescence readout is reduced due to the acidic substances that are produced in the glucometabolic process of bacteria toward sugar molecules, which can decrease the pH of the sensing system. More importantly, E. coli and S. aureus differ in terms of their sugar metabolic capability on lactose and thus can lead to distinguishable fluorescence signals, which are used to further distinguish E. coli from S. aureus. The detection limits (LODs) for E. coli and S. aureus are 21 CFU mL(-1) and 33 CFU mL(-1), respectively, in the presence of glucose and 762 CFU mL(-1) for E. coli in the presence of lactose. This p-CD-based fluorescence approach is simple, sensitive and free of any modification steps; thus, it has a much broader field of potential applications than other approaches.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Positively Charged and pH-sensitive Carbon Dots for Fluorescence Detection of Copper Ion
    Feng, Feng
    Miao, Chenfang
    Zhang, Yalan
    Huang, Zhengjun
    Weng, Shaohuang
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2021, 42 (02) : 227 - 234
  • [22] pH-sensitive tunable thermochromic hydrogel with carbon quantum dots for smart windows
    Sai Zhong
    Yuxuan Xue
    Kuanwen Wang
    Haoyang Li
    Yanghua Lu
    Zhenqian Pang
    Tengyao Jiang
    Gang Tan
    National Science Open, 2024, 3 (03) : 29 - 49
  • [23] Urea detection in milk by urease-assisted pH-sensitive carbon dots
    Yin, Wenzhi
    Zhang, Ye
    Gu, Jiao
    Wang, Tingyu
    Ma, Chaoqun
    Zhu, Chun
    Li, Lei
    Yang, Zichen
    Zhu, Tuo
    Chen, Guoqing
    APPLIED OPTICS, 2021, 60 (33) : 10421 - 10428
  • [24] Mechanistic insights into pH-sensitive photoluminescence of carbon dots: The role of carboxyl group
    Zhou, Yujie
    Ye, Chunyin
    Zhang, Jiachen
    Jiang, Shenlong
    Zhang, Qun
    JOURNAL OF CHEMICAL PHYSICS, 2024, 161 (23):
  • [25] Selective Bacterial Growth Inactivation by pH-Sensitive Sulfanilamide Functionalized Carbon Dots
    Mishra, Anurag
    Lzaod, Stanzin
    Dutta, Tanmay
    Bhattacharya, Sagarika
    ACS APPLIED BIO MATERIALS, 2024, 7 (05): : 2752 - 2761
  • [26] Quantification of nanoparticle endocytosis based on double fluorescent pH-sensitive nanoparticles
    Kurtz-Chalot, Andrea
    Klein, Jean-Philippe
    Pourchez, Jeremie
    Boudard, Delphine
    Bin, Valerie
    Sabido, Odile
    Marmuse, Laurence
    Cottier, Michele
    Forest, Valerie
    BIOMEDICAL MICRODEVICES, 2015, 17 (02)
  • [27] Smartphone-based portable device for rapid and sensitive pH detection by fluorescent carbon dots
    Ehtesabi, Hamide
    Asadollahi, Amir
    Hallaji, Zahra
    Goudarzi, Mahsa
    Rezaei, Ali
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 332
  • [28] Quantification of nanoparticle endocytosis based on double fluorescent pH-sensitive nanoparticles
    Andréa Kurtz-Chalot
    Jean-Philippe Klein
    Jérémie Pourchez
    Delphine Boudard
    Valérie Bin
    Odile Sabido
    Laurence Marmuse
    Michèle Cottier
    Valérie Forest
    Biomedical Microdevices, 2015, 17
  • [29] Preparation of a pH-sensitive polystyrene fluorescent microsphere based on a cyanine dye
    Yu, Liang
    Wang, Qiuling
    Li, Tingting
    Chen, Ligong
    JOURNAL OF CHEMICAL RESEARCH, 2012, (11) : 632 - 634
  • [30] A xylenol orange-based pH-sensitive sensor array for identification of bacteria and differentiation of probiotic drinks
    Yang, Changmao
    Xiao, Yue
    Yan, Yunjun
    Zhang, Houjin
    ANALYTICAL METHODS, 2025, 17 (03) : 525 - 532