Shear behavior of perfobond connectors in the steel-concrete joints of hybrid bridges

被引:27
|
作者
Zou, Yang [1 ,2 ,3 ]
Di, Jin [1 ,2 ]
Zhou, Jianting [3 ]
Zhang, Zhongya [3 ]
Li, Xiujun [3 ]
Zhang, Hong [3 ]
Qin, Fengjiang [1 ,2 ]
机构
[1] Chongqing Univ, Key Lab New Technol Construct Cities Mt Area, 83 Shabei St, Chongqing 400030, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, 83 Shabei St, Chongqing 400030, Peoples R China
[3] Chongqing Jiaotong Univ, State Key Lab Mt Bridge & Tunnel Engn, Chongqing 400074, Peoples R China
基金
中国国家自然科学基金;
关键词
Steel-concrete joints; Perfobond connector; Shear behavior; Finite element analysis; Dilatancy; SHAPED COMPOSITE DOWELS; PUSH-OUT TEST; CRACKED CONCRETE; MODEL; RESISTANCE; CAPACITY; TESTS; BEAMS;
D O I
10.1016/j.jcsr.2020.106217
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The perfobond connector is the most widely used connector in the steel-concrete joint, and its shear behavior is different from that of perfobond connectors in steel-concrete composite beams. However, because of the limitations of the parameters considered in previous tests and the difficulty of measuring the internal stress states of test specimens, the force transfer mechanisms of perfobond connectors in steel-concrete joints remain unclear. To clarify shear behavior of perfobond connectors in the steel-concrete joints of hybrid bridges, an effective finite element model of push-out testing is developed. Finite element analysis results indicated that: the dilatancy effect of concrete dowel causes concrete cracking, and the shear capacity of connectors is mainly controlled by the confinements of structural reinforcement in they direction. In the case of weak confinements from structural reinforcement, the confinement effects of friction force at the bottom of a specimen significantly affects the mechanical properties of concrete dowels. Pressure fields can slightly enhance the shear capacity of connectors, whereas tension fields can significantly reduce the ultimate shear capacity of connectors. With an increase in confinements, the shear and tension forces of the perforating rebar in the ultimate state gradually shift toward pure shear forces. Because of the separation of steel-concrete interfaces caused by the dilatancy of concrete dowels, the contribution of interface bond friction to the shear capacity of connectors should be considered as a safety reserve. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Study of direct shear of the adhesion connectors steel-concrete
    Azdine, Ilhame
    Kissi, Benaissa
    Khatib, Hamza
    2022 2ND INTERNATIONAL CONFERENCE ON INNOVATIVE RESEARCH IN APPLIED SCIENCE, ENGINEERING AND TECHNOLOGY (IRASET'2022), 2022, : 397 - 400
  • [32] SHEAR CONNECTORS IN STEEL-CONCRETE COMPOSITE BEAMS FOR BRIDGES AND NEW CP 117 .2.
    MAINSTONE, RJ
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS, 1967, 38 (SEP): : 83 - +
  • [33] Strength of shear connectors in steel-concrete composite beams
    Madheswaran, C.K.
    Natarajan, K.
    Prakash, A.
    Journal of the Institution of Engineers (India): Civil Engineering Division, 2007, 88 (AUG.): : 14 - 20
  • [34] STEEL-CONCRETE COMPOSITE PLATES WITH FLEXIBLE SHEAR CONNECTORS
    CLARKE, JL
    MORLEY, CT
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1972, 53 (DEC): : 557 - 568
  • [35] Structural performance of steel-concrete composite bridges utilising innovative blind bolt shear connectors
    Hosseini, Seyedeh Maryam
    Mashiri, Fidelis
    Mirza, Olivia
    Hart, Brendan
    STEEL AND COMPOSITE STRUCTURES, 2021, 40 (04): : 581 - 600
  • [36] SHEAR CONNECTORS IN STEEL-CONCRETE COMPOSITE BEAMS FOR BRIDGES .2. FATIGUE TESTS ON BEAMS
    MAINSTONE, RJ
    MENZIES, JB
    CONCRETE, 1967, 1 (10): : 351 - +
  • [37] Experimental and Software Analysis of Composite Action in Steel-Concrete Composite Bridges with Continuous Shear Connectors
    Kvočák, Vincent
    Kožlejová, Viktória
    Dubecký, Daniel
    Kanishchev, Ruslan
    Vaňová, Patrícia
    ce/papers, 2019, 3 (3-4) : 307 - 312
  • [38] Experimental study on CFSC encased shear connectors in steel-concrete composite joints with UHPC grout
    He, Shaohua
    Mosallam, Ayman S.
    Fang, Zhi
    Zou, Chao
    Feng, Wenxian
    Su, Jie
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 173 : 638 - 649
  • [39] Fatigue performance of perfobond shear connector in steel-concrete composite structure
    Wei, X. (we_star@swjtu.cn), 1600, Chang'an University (26):
  • [40] Investigation on structural performance of perfobond strip connector group in steel-concrete joints
    He, Shaohua
    Guan, Peidong
    Wang, Qiao
    Fang, Zhi
    Mosallam, Ayman
    ENGINEERING STRUCTURES, 2021, 242