The scavenging of volatile anesthetic agents in the cardiovascular intensive care unit environment: a technical report

被引:0
|
作者
Pickworth, Thomas [1 ]
Jerath, Angela [1 ,2 ]
DeVine, Rita [3 ]
Kherani, Nazmin [3 ]
Wasowicz, Marcin [1 ,2 ]
机构
[1] Univ Hlth Network, Toronto Gen Hosp, Dept Anesthesia & Pain Management, Toronto, ON M5G 2C4, Canada
[2] Univ Toronto, Fac Med, Dept Anesthesia, Toronto, ON, Canada
[3] Univ Hlth Network, Toronto Gen Hosp, Dept Resp Therapy, Toronto, ON, Canada
来源
CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 2013年 / 60卷 / 01期
关键词
ISOFLURANE; SEDATION; DESFLURANE; POLLUTION;
D O I
10.1007/s12630-012-9814-5
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The use of volatile-based sedation within critical care environments has been limited by difficulties of drug administration and safety concerns over environment pollution and staff exposure in an intensive care unit (ICU) with no scavenging. The aim of this study was to develop a simple scavenging system to be used with the Anesthesia Conserving Device (AnaConDa(A (R))) and to determine whether or not ambient concentrations of residual anesthetic are within current acceptable limits. The scavenging system consists of two Deltasorb(A (R)) canisters attached to the ICU ventilator in series. AnaConDa is a miniature vaporizer designed to provide volatile-based sedation within an ICU. The first ten patients recruited into a larger randomized trial assessing outcomes after elective coronary graft bypass surgery were sedated within the cardiac ICU using either isoflurane or sevoflurane. Sedation was guided by the Sedation Agitation Scale, resulting in an end-tidal minimum anesthetic concentration of volatile agent ranging from 0.1-0.3. At one hour post ICU admission, infrared photometric analysis was used to assess environmental contamination at four points along the ventilator circuit and scavenging system and around the patient's head. All measurements taken within the patient's room were below 1 part per million, which satisfies criteria for occupational exposure. This study shows that volatile agents can be administered safely within critical care settings using a simple scavenging system. Our scavenging system used in conjunction with the AnaConDa device reduced the concentration of environmental contamination to a level that is acceptable to Canadian standards and standards in most Western countries and thus conforms to international safety standards. The related clinical trial was registered at www.clinicaltrials.gov (NCT01151254).
引用
收藏
页码:38 / 43
页数:6
相关论文
共 50 条
  • [41] Evolved role of the cardiovascular intensive care unit (CICU)
    Kasaoka, Shunji
    JOURNAL OF INTENSIVE CARE, 2017, 5
  • [42] Dentistry and Intensive Care Unit: A Brief Report
    Bannwart, Lisiane Cristina
    Neto, Clovis Lamartine de Moraes Melo
    dos Santos, Daniela Micheline
    Moreno, Andre Luiz de Melo
    Pesqueira, Aldieris Alves
    Goiato, Marcelo Coelho
    Bertoz, Andre Pinheiro de Magalhaes
    EUROPEAN JOURNAL OF DENTISTRY, 2022, 16 (02) : 449 - 453
  • [43] PLANNING INTENSIVE CARE UNIT - PRELIMINARY REPORT
    FISKE, S
    HUBER, HS
    LANDMAN, EC
    NEW YORK STATE JOURNAL OF MEDICINE, 1961, 61 (24) : 4272 - &
  • [44] Neonatal intensive care unit report cards
    Perlman, M
    PEDIATRICS, 1998, 102 (04) : 975 - 976
  • [45] DETERMINATION OF CONTAMINATION OF A CHEMICAL WARFARE-PROOF OPERATING-THEATER WITH VOLATILE ANESTHETIC AGENTS AND ASSESSMENT OF ANESTHETIC GAS SCAVENGING SYSTEMS
    YOGANATHAN, S
    JOHNSTON, IG
    PARNELL, CJ
    HOUGHTON, IT
    RESTALL, J
    BRITISH JOURNAL OF ANAESTHESIA, 1991, 67 (05) : 614 - 617
  • [46] Plasma exchange in the intensive care unit: Technical aspects and complications
    Lemaire, Aurelie
    Parquet, Nathalie
    Galicier, Lionel
    Boutboul, David
    Bertinchamp, Remi
    Malphettes, Marion
    Dumas, Guillaume
    Mariotte, Eric
    Peraldi, Marie-Noelle
    Souppart, Virginie
    Schlemmer, Benoit
    Azoulay, Elie
    Canet, Emmanuel
    JOURNAL OF CLINICAL APHERESIS, 2017, 32 (06) : 405 - 412
  • [47] Planning the acoustic environment of a neonatal intensive care unit
    Philbin, MK
    CLINICS IN PERINATOLOGY, 2004, 31 (02) : 331 - +
  • [48] Ethics in the intensive care unit - Creating an ethical environment
    Nelson, RM
    CRITICAL CARE CLINICS, 1997, 13 (03) : 691 - +
  • [49] Living with alarms: the audio environment in an intensive care unit
    Sinclair, Peter
    AI & SOCIETY, 2012, 27 (02) : 269 - 276
  • [50] Characterizing the acoustic environment in a Neonatal Intensive Care Unit
    Hernandez-Molina, Ricardo
    Beira Jimenez, J. L.
    Rodriguez-Montano, Victor
    Fernandez Zacarias, F.
    Bienvenido-Huertas, David
    Lubian Lopez, Simon
    Luis Cueto-Ancela, Jose
    APPLIED ACOUSTICS, 2020, 165