Multiobjective optimization framework for landmark measurement error correction in three-dimensional cephalometric tomography

被引:11
|
作者
DeCesare, A. [1 ]
Secanell, M. [1 ]
Lagravere, M. O. [2 ]
Carey, J. [1 ]
机构
[1] Univ Alberta, Fac Engn, Dept Mech Engn, Edmonton, AB T6G 1C9, Canada
[2] Univ Alberta, Fac Med & Dent, Dept Dent, Orthodont Grad Program, Edmonton, AB T6G 1C9, Canada
关键词
cone beam computed tomography; orthodontics; maxillary expansion treatment; landmark optimization procedure; BEAM COMPUTERIZED-TOMOGRAPHY; PLANE ORIENTATION; ORTHOGNATHIC SURGERY; MAXILLARY EXPANSION; CRANIAL BASE; CLEFT-LIP; GROWTH; IMAGES; SUPERIMPOSITION; RELIABILITY;
D O I
10.1259/dmfr.20130035
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study is to minimize errors that occur when using a four vs six landmark superimpositioning method in the cranial base to define the co-ordinate system. Cone beam CT volumetric data from ten patients were used for this study. Co-ordinate system transformations were performed. A co-ordinate system was constructed using two planes defined by four anatomical landmarks located by an orthodontist. A second co-ordinate system was constructed using four anatomical landmarks that are corrected using a numerical optimization algorithm for any landmark location operator error using information from six landmarks. The optimization algorithm minimizes the relative distance and angle between the known fixed points in the two images to find the correction. Measurement errors and co-ordinates in all axes were obtained for each co-ordinate system. Significant improvement is observed after using the landmark correction algorithm to position the final co-ordinate system. The errors found in a previous study are significantly reduced. Errors found were between 1 mm and 2 mm. When analysing real patient data, it was found that the 6-point correction algorithm reduced errors between images and increased intrapoint reliability. A novel method of optimizing the overlay of three-dimensional images using a 6-point correction algorithm was introduced and examined. This method demonstrated greater reliability and reproducibility than the previous 4-point correction algorithm.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Cone-Beam Computed Tomography-Based Three-Dimensional McNamara Cephalometric Analysis
    Goncalves dos Santos, Rodrigo Mologni
    De Martino, Jose Mario
    Haiter Neto, Francisco
    Passeri, Luis Augusto
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (04) : 895 - 899
  • [32] Author Correction: Three-dimensional soft tissue landmark detection with marching cube algorithm
    Yoonjung Lee
    Ji-Min Lee
    Sun-Hyung Park
    Yoon Jeong Choi
    Sung-Hwan Choi
    Jae Joon Hwang
    Hyung-Seog Yu
    Scientific Reports, 13
  • [33] Error consideration in contrast-enhanced three-dimensional optical tomography
    Hawrysz, DJ
    Eppstein, MJ
    Lee, JW
    Sevick-Muraca, EM
    OPTICS LETTERS, 2001, 26 (10) : 704 - 706
  • [34] Interactive multiobjective optimization for anatomy-based three-dimensional HDR brachytherapy
    Ruotsalainen, Henri
    Miettinen, Kaisa
    Palmgren, Jan-Erik
    Lahtinen, Tapani
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16): : 4703 - 4719
  • [35] Optimization of Three-Dimensional Wings in Ground Effect Using Multiobjective Genetic Algorithm
    Lee, Sang-Hwan
    Lee, Juhee
    JOURNAL OF AIRCRAFT, 2011, 48 (05): : 1633 - 1645
  • [36] Measurement of global instability of compact torus by three-dimensional tomography
    Kawamori, E.
    Sumikawa, T.
    Ono, Y.
    Balandin, A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (09):
  • [37] Three-dimensional vector velocity measurement in optical doppler tomography
    Meng, Jie
    Ding, Zhihua
    Zhu, Ying
    Guangxue Xuebao/Acta Optica Sinica, 2009, 29 (11): : 3168 - 3172
  • [38] Multiobjective Optimization Approach to Multidisciplinary Design of a Three-dimensional Transonic Compressor Blade
    Luo, Chang
    Song, Liming
    Li, Jun
    Feng, Zhenping
    PROCEEDINGS OF ASME TURBO EXPO 2009, VOL 7, PTS A AND B, 2009, : 599 - 608
  • [39] GPS Error Correction With Pseudorange Evaluation Using Three-Dimensional Maps
    Miura, Shunsuke
    Hsu, Li-Ta
    Chen, Feiyu
    Kamijo, Shunsuke
    IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2015, 16 (06) : 3104 - 3115
  • [40] Three-dimensional electrical impedance, tomography: A topology optimization approach
    Mello, Luis Augusto Motta
    De Lima, Cicero Ribeiro
    Amato, Marcelo Britto Passos
    Lima, Raul Gonzalez
    Silva, Emilio Carlos Nelli
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (02) : 531 - 540