High-throughput screening for new psychoactive substances (NPS) in whole blood by DLLME extraction and UHPLC-MS/MS analysis

被引:88
|
作者
Odoardi, Sara [1 ]
Fisichella, Marco [1 ]
Romolo, Francesco Saverio [2 ,3 ]
Strano-Rossi, Sabina [1 ]
机构
[1] Univ Cattolica Sacro Cuore, Sect Legal Med, Inst Publ Hlth, I-00168 Rome, Italy
[2] Univ Lausanne, Inst Police Sci, CH-1015 Lausanne, Switzerland
[3] Univ Roma La Sapienza, Legal Med Sect, I-00185 Rome, Italy
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2015年 / 1000卷
关键词
NPS; UHPLC-MS/MS; Blood; DLLME; Forensic toxicology; Clinical toxicology; TANDEM MASS-SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; SYNTHETIC CANNABINOIDS; DESIGNER DRUGS; ALPHA-PYRROLIDINOVALEROPHENONE; FATAL INTOXICATION; SEIZED MATERIALS; LEGAL-HIGHS; UPLC-MS/MS; CHROMATOGRAPHY;
D O I
10.1016/j.jchromb.2015.07.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The increasing number of new psychoactive substances (NPS) present in the illicit market render their identification in biological fluids/tissues of great concern for clinical and forensic toxicology. Analytical methods able to detect the huge number of substances that can be used are sought, considering also that many NPS are not detected by the standard immunoassays generally used for routine drug screening. The aim of this work was to develop a method for the screening of different classes of NPS (a total of 78 analytes including cathinones, synthetic cannabinoids, phenethylamines, piperazines, ketamine and analogues, benzofurans, tryptamines) from blood samples. The simultaneous extraction of analytes was performed by Dispersive Liquid/Liquid Microextraction DLLME, a very rapid, cheap and efficient extraction technique that employs microliters amounts of organic solvents. Analyses were performed by a target Ultrahigh Performance Liquid Chromatography tandem Mass Spectrometry (UHPLC-MS/MS) method in multiple reaction monitoring (MRM). The method allowed the detection of the studied analytes with limits of detection (LODs) ranging from 0.2 to 2 ng/mL. The proposed DLLME method can be used as an alternative to classical liquid/liquid or solid-phase extraction techniques due to its rapidity, necessity to use only microliters amounts of organic solvents, cheapness, and to its ability to extract simultaneously a huge number of analytes also from different chemical classes. The method was then applied to 60 authentic real samples from forensic cases, demonstrating its suitability for the screening of a wide number of NPS. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:57 / 68
页数:12
相关论文
共 50 条
  • [21] GC-MS analysis of underivatised new psychoactive substances in whole blood and urine
    Alexandridou, Anastasia
    Mouskeftara, Thomai
    Raikos, Nikolaos
    Gika, Helen G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1156
  • [22] SOLID-PHASE EXTRACTION COMBINED WITH UHPLC-MS/MS METHOD FOR DETERMINATION OF REMIFENTANIL IN HUMAN WHOLE BLOOD
    Lv, Jinling
    Li, Yanhua
    Jin, Hua
    Shi, Yao
    Xia, Qinghai
    Yang, Yaling
    ANALYTICAL LETTERS, 2012, 45 (10) : 1133 - 1142
  • [23] Development of a multi-residue high-throughput UHPLC-MS/MS method for routine monitoring of SARM compounds in equine and bovine blood
    Ventura, Emiliano
    Gadaj, Anna
    Buckley, Tom
    Mooney, Mark H.
    DRUG TESTING AND ANALYSIS, 2020, 12 (09) : 1373 - 1379
  • [24] High-throughput, simultaneous quantitation of hemoglobin adducts of acrylamide, glycidamide, and ethylene oxide using UHPLC-MS/MS
    Yang, Min
    Frame, Tunde
    Tse, Chui
    Vesper, Hubert W.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1086 : 197 - 205
  • [25] Development of a high-throughput UHPLC-MS/MS method for the analysis of Fusarium and Alternaria toxins in cereals and cereal-based food
    Dick, Fabian
    Dietz, Alena
    Asam, Stefan
    Rychlik, Michael
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (26) : 5619 - 5637
  • [26] Determination of psychoactive drugs in serum using conductive vial electromembrane extraction combined with UHPLC-MS/MS
    Skaalvik, Tonje Gottenberg
    Oiestad, Elisabeth Leere
    Trones, Roger
    Pedersen-Bjergaard, Stig
    Hegstad, Solfrid
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1183
  • [27] Development of a high-throughput UHPLC-MS/MS (SRM) method for the quantitation of endogenous glucagon from human plasma
    Howard, James W.
    Kay, Richard G.
    Tan, Tricia
    Minnion, James
    Ghatei, Mohammad
    Bloom, Steve
    Creaser, Colin S.
    BIOANALYSIS, 2014, 6 (24) : 3295 - 3309
  • [28] Screening of 104 New Psychoactive Substances (NPS) and Other Drugs of Abuse in Oral Fluid by LC-MS-MS
    da Cunha, Kelly Francisco
    Oliveira, Karina Diniz
    Huestis, Marilyn A.
    Costa, Jose Luiz
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2020, 44 (07) : 697 - 707
  • [29] Determination of cocaine, metabolites and a crack cocaine biomarker in whole blood by liquid-liquid extraction and UHPLC-MS/MS
    Takitane, Juliana
    Leyton, Vilma
    Andreuccetti, Gabriel
    Gjerde, Hallvard
    Vindenes, Vigdis
    Berg, Thomas
    FORENSIC SCIENCE INTERNATIONAL, 2018, 289 : 165 - 174
  • [30] Determination of new psychoactive substances and other drugs in postmortem blood and urine by UHPLC–MS/MS: method validation and analysis of forensic samples
    Ettore Ferrari Júnior
    Eloisa Dutra Caldas
    Forensic Toxicology, 2022, 40 : 88 - 101