EUV emission from Kr and Xe capillary discharge plasmas

被引:21
|
作者
Juschkin, L
Chuvatin, A
Zakharov, SV
Ellwi, S
Kunze, HJ
机构
[1] Ruhr Univ Bochum, Inst Expt Phys 5, D-4630 Bochum, Germany
[2] Ecole Polytech, Palaiseau, France
[3] EPPRA SAS, Ile Sci Ind, St Aubin, France
[4] TRINITI, Troitsk, Russia
关键词
D O I
10.1088/0022-3727/35/3/309
中图分类号
O59 [应用物理学];
学科分类号
摘要
Kr and Xe plasmas are very intensive emitters in the spectral range of 100-150 Angstrom, which is relevant for a number of applications (for example microlithography). We present investigations of the extreme utraviolet (EUV) emission from a slow capillary discharge with Kr and Xe fillings. The emission of Kr ions (Kr VIII to Kr XI) within the range of 70-150 Angstrom consists of three bands of lines of about 10 Angstrom width with maxima at 116, 103 and 86 Angstrom. Xe emission bands of about 15 Angstrom width have their maxima at 136 and 115 Angstrom (Xe IX to Xe XII). The radiation duration in this spectral range is similar to 150 ns for both elements. At the optimum conditions, the Kr emission at 103 Angstrom is 2-3 times more intense than the Xe emission at 136 Angstrom. The measured spectral energy of Kr radiation is about 0.1 J sr(-1) Angstrom(-1). Experimental results are compared with numerical modellings of the dynamics and emission of the capillary discharge plasma, which enables the determination of plasma parameters and the future use of the codes as additional instruments for plasma diagnostics.
引用
收藏
页码:219 / 227
页数:9
相关论文
共 50 条
  • [21] Forward Modeling of EUV and Gyrosynchrotron Emission from Coronal Plasmas with FoMo
    Van Doorsseiaere, Tom
    Antolin, Patrick
    Yuan, Ding
    Reznikova, Veronika
    Magyar, Norbert
    FRONTIERS IN ASTRONOMY AND SPACE SCIENCES, 2016, 3
  • [22] Effective emission of Xe*2 and Kr*2 excited by a pulsed corona discharge bounded by a dielectric barrier
    Lisenko, A. A.
    Lomaev, M. I.
    Skakun, V. S.
    Tarasenko, V. F.
    PHYSICA SCRIPTA, 2007, 76 (03) : 211 - 215
  • [23] Analysis of the X-ray and time-resolved XUV emission of laser produced Xe and Kr plasmas
    Bastiani-Ceccotti, S.
    Kontogiannopoulos, N.
    Marques, J-R
    Tzortzakis, S.
    Lecherbourg, L.
    Thais, F.
    Matsushima, I.
    Peyrusse, O.
    Chenais-Popovics, C.
    HIGH ENERGY DENSITY PHYSICS, 2007, 3 (1-2) : 20 - 27
  • [24] Temporal measurements of extreme ultraviolet (EUV) emission, from low temperature, EUV-induced plasmas
    Bartnik, A.
    Fiedorowicz, H.
    Wachulak, P.
    Fok, T.
    LASER AND PARTICLE BEAMS, 2018, 36 (03) : 286 - 292
  • [25] Discharge plasmas as EUV sources for future micro lithography
    Kruecken, Thomas
    Atomic Processes in Plasmas, 2007, 926 : 259 - 269
  • [26] Measurements of the viscosities of Kr and Xe by the two-capillary viscometry
    Lin, H.
    Che, J.
    Zhang, J. T.
    Feng, X. J.
    FLUID PHASE EQUILIBRIA, 2016, 418 : 198 - 203
  • [27] Reactive oxygen emission from microwave discharge plasmas
    Popovic, S.
    Raskovic, M.
    Kuo, S. P.
    Vuskovic, L.
    RADICALS AND NON-EQUILIBRIUM PROCESSES IN LOW-TEMPERATURE PLASMAS, 2007, 86
  • [28] Experimental Study of Soft X-ray Emission from Pd-Like Xe Pumped by Capillary Discharge
    Y. Zhao
    M. Xu
    Y. Xie
    L. Li
    Sh. Jiang
    H. Cui
    Q. Wang
    Journal of Applied Spectroscopy, 2014, 81 : 503 - 508
  • [29] Experimental Study of Soft X-ray Emission from Pd-Like Xe Pumped by Capillary Discharge
    Zhao, Y.
    Xu, M.
    Xie, Y.
    Li, L.
    Jiang, Sh
    Cui, H.
    Wang, Q.
    JOURNAL OF APPLIED SPECTROSCOPY, 2014, 81 (03) : 503 - 508
  • [30] EUV emission from gas discharges produced plasmas with solid tin as target
    Zhang, CH
    Katsuki, S
    Imamura, H
    Horita, H
    Namihira, T
    Akiyama, H
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (23) : 4191 - 4195