Evaluation of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) for sulfur metabolic studies using 34S-labelled yeast

被引:8
|
作者
Galilea San Blas, Oscar [1 ]
Marchante Gayon, Juan Manuel [1 ]
Garcia Alonso, Jose Ignacio [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
TRACE;
D O I
10.1039/c4ja00383g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multi-collector ICP-MS instrument was evaluated for the on-line measurement of sulfur isotope ratios during the liquid chromatographic separation of sulfur metabolites in mouse urine after the oral administration of S-34-labelled yeast. The multi-collector instrument used was equipped with both Faraday cups and ion counters at positions L4 (32), C (33) and H4 (34). For the optimisation of the resolution, cup configuration and measurement conditions an artificial mixture of natural sulfur and highly enriched S-33 and S-34 was prepared. The results were compared with those obtained using a sector field single collector instrument from the same manufacturer. Both instruments provided good accuracy in the measurement of sulfur isotope ratios but better precision (<0.01%) was obtained with the multicollector instrument. For HPLC coupling a nebulization-desolvation system (Aridus II) was used to eliminate the high amounts of methanol present in the mobile phases and maintain the sensitivity for sulfur during the gradient separation of urinary metabolites. Preliminary sulfur metabolism studies were carried out feeding healthy mice and mice with prostate cancer with one dose of yeast enriched with S-34 and measuring the sulfur metabolites in urine at different times using a S-33 solution as a post-column spike. Chromatograms obtained showed different sulfur isotope enrichments for several metabolites in healthy and diseased mice. However, the variability in retention times from sample to sample hindered the interpretation of the results. Additionally, the number of samples is not enough to draw any metabolic conclusions at this stage.
引用
收藏
页码:1764 / 1773
页数:10
相关论文
共 50 条
  • [1] Lead isotope measurement using a multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Choi, Hye-Bin
    Ryu, Jong-Sik
    Park, Sanghee
    Lee, Jeonghoon
    JOURNAL OF THE GEOLOGICAL SOCIETY OF KOREA, 2018, 54 (03) : 311 - 318
  • [2] Precise measurement of Fe isotopes in marine samples by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    de Jong, Jeroen
    Schoemann, Veronique
    Tison, Jean-Louis
    Becquevort, Sylvie
    Masson, Florence
    Lannuzel, Delphine
    Petit, Jerome
    Chou, Lei
    Weis, Dominique
    Mattielli, Nadine
    ANALYTICA CHIMICA ACTA, 2007, 589 (01) : 105 - 119
  • [3] Precise measurement of uranium isotope ratios in Fukushima soils using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Murugan, Rajamanickam
    Veerasamy, Nimelan
    Zhao, Ye
    Aono, Tatsuo
    Sahoo, Sarata Kumar
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 467
  • [4] Determination of indium isotopic ratios of geostandards with different matrices by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Zhu, Chuanwei
    Wu, Yunzhu
    Liu, Zerui
    Zhou, Meifu
    Yang, Guangshu
    Zhang, Yuxu
    Wen, Hanjie
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (07) : 1867 - 1873
  • [5] Refining Boron Isotopic Measurements of Silicate Samples by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometry (MC-ICP-MS)
    Paul, Andre N.
    Stewart, Joseph A.
    Agostini, Samuele
    Kirstein, Linda A.
    De Hoog, Jan C. M.
    Savov, Ivan P.
    Walowski, Kristina
    Rae, James W. B.
    Elliott, Tim
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024, 48 (01) : 91 - 108
  • [6] Determination of Stable Silicon Isotopes Using Multi-Collector Inductively Coupled Plasma Mass Spectrometry
    Zhang An-Yu
    Zhang Jing
    Zhang Rui-Feng
    Xue Yun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (09) : 1353 - 1358
  • [7] Accurate and Precise 230Th/232Th Isotope Ratio Measurement by Multi-Collector Inductively Coupled Plasma Mass Spectrometry Using a Pre-Cell Mass Filter for Collision/Reaction Cell (Mc-Icp-Ms/Ms)
    Varga, Zsolt
    Wallenius, Maria
    Mayer, Klaus
    SSRN,
  • [8] Accurate and precise 230Th/232Th isotope ratio measurement by multi-collector inductively coupled plasma mass spectrometry using a pre-cell mass filter for collision/reaction cell (MC-ICP-MS/MS)
    Varga, Zsolt
    Wallenius, Maria
    Mayer, Klaus
    TALANTA, 2025, 292
  • [9] High-precision measurement of calcium isotopes in carbonates and related materials by multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Halicz, L
    Galy, A
    Belshaw, NS
    O'Nions, RK
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) : 1835 - 1838
  • [10] Measurement of isotopic ratios of uranium by multi-collector inductively coupled plasma mass spectrometry
    Li, Li-Li
    Li, Jin-Ying
    Zhao, Yong-Gang
    Liu, Jun-Ling
    Zhang, Ji-Long
    He-Huaxue yu Fangshe Huaxue/Journal of Nuclear and Radiochemistry, 2006, 28 (03): : 152 - 156