共 50 条
Refining Boron Isotopic Measurements of Silicate Samples by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometry (MC-ICP-MS)
被引:2
|作者:
Paul, Andre N.
[1
,2
,3
]
Stewart, Joseph A.
[2
]
Agostini, Samuele
[4
]
Kirstein, Linda A.
[1
]
De Hoog, Jan C. M.
[1
]
Savov, Ivan P.
[5
]
Walowski, Kristina
[1
,6
]
Rae, James W. B.
[7
]
Elliott, Tim
[2
]
机构:
[1] Univ Edinburgh, Sch Geosci, Edinburgh EH9 3FE, Scotland
[2] Univ Bristol, Sch Earth Sci, Bristol, England
[3] Univ Geneva, Dept Earth Sci, Geneva, Switzerland
[4] Consiglio Nazl Ric CNR, Ist Geosci & Georisorse, Pisa, Italy
[5] Univ Leeds, Sch Earth & Environm, Leeds, England
[6] Western Washington Univ, Dept Geol, Bellingham, WA USA
[7] Univ St Andrews, Sch Earth & Environm Sci, St Andrews, Scotland
关键词:
delta B-11(SRM 951);
MORB volcanic glass;
OIB volcanic glass;
silicate reference materials;
MC-ICP-MS;
HF digestion;
boron isotopes;
EAST PACIFIC RISE;
ROCK SAMPLES;
GEOLOGICAL-MATERIALS;
IN-SITU;
EVAPORATION;
EXCHANGE;
PRECISE;
RIDGE;
MICROSUBLIMATION;
PURIFICATION;
D O I:
10.1111/ggr.12527
中图分类号:
P3 [地球物理学];
P59 [地球化学];
学科分类号:
0708 ;
070902 ;
摘要:
Solution MC-ICP-MS is an established technique for high precision boron isotope measurement results (delta B-11(SRM 951)) in carbonates, yet its application to silicate rocks has been limited. Impediments include volatilisation during silicate dissolution and contamination during chemical purification. To address this, we present a low-blank sample preparation procedure that couples hydrofluoric acid-digestion and low-temperature evaporation (mannitol-free), to an established MC-ICP-MS measurement procedure following chemical purification using B-specific Amberlite IRA 743 resin. We obtain accurate delta B-11(SRM 951) values (intermediate precision +/- 0.2 parts per thousand) for boric acid (BAM ERM-AE121 19.65 +/- 0.14 parts per thousand) and carbonate (NIST RM 8301 (Coral) 24.24 +/- 0.11 parts per thousand) reference materials. For silicate reference materials covering mafic to felsic compositions we obtain delta B-11(SRM 951) with intermediate precision < +/- 0.6 parts per thousand (2s), namely JB-2 6.9 +/- 0.4 parts per thousand; IAEA-B-5 -6.0 +/- 0.6 parts per thousand; IAEA-B-6 -3.9 +/- 0.5 parts per thousand (2s). Furthermore, splits of these same reference materials were processed by an alternative fusion and purification procedure. We find excellent agreement between delta B-11(SRM 951) measurement results by MC-ICP-MS of the reference materials using both sample processing techniques. These measurement results show that our sample processing and MC-ICP-MS methods provide consistent delta B-11(SRM 951) values for low B-mass fraction samples. We present new data from Mid Ocean Ridge Basalt (MORB) glass, documenting a range in delta B-11(SRM 951) from -5.6 +/- 0.3 parts per thousand to -8.8 +/- 0.5 parts per thousand (2s), implying some upper mantle delta B-11(SRM 951) heterogeneity.
引用
收藏
页码:91 / 108
页数:18
相关论文