CR-39 detector based thermal neutron flux measurements, in the photo neutron project

被引:9
|
作者
Mameli, A. [2 ]
Greco, F. [2 ]
Fidanzio, A. [2 ]
Fusco, V.
Cilla, S. [3 ]
D'Onofrio, G. [3 ]
Grimaldi, L. [3 ]
Augelli, B. G. [3 ]
Giannini, G. [4 ,5 ]
Bevilacqua, R. [4 ,5 ]
Totaro, P. [4 ,5 ]
Tommasino, L.
Azario, L. [1 ]
Piermattei, A. [1 ]
机构
[1] Univ Cattolica Sacro Cuore, Ist Fis, Rome, Italy
[2] Univ Cattolica Sacro Cuore, UO Fis Sanit Policlin A Gemelli, Rome, Italy
[3] Univ Cattolica Sacro Cuore, UO Fis Sanit, Ctr Ric & Formaz Ad Alta Tecnol Sci Biomed, Campobasso, Italy
[4] Univ Trieste, Dipartimento Fis, Trieste, Italy
[5] Ist Nazl Fis Nucl, Sez Trieste, Trieste, Italy
关键词
neutron; CR-39; BNCT;
D O I
10.1016/j.nimb.2008.05.122
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
PhoNeS (photo neutron source) is a project aimed at the production and moderation of neutrons by exploiting high energy linear accelerators, currently used in radiotherapy. A feasibility study has been carried out with the scope in mind to use the high energy photon beams from these accelerators for the production of neutrons suitable for boron neutron capture therapy (BNCT). Within these investigations, it was necessary to carry out preliminary measurements of the thermal neutron component of neutron spectra, produced by the photo-conversion of X-ray radiotherapy beams supplied by three LinAcs: 15 MV, 18 MV and 23 MV. To this end, a simple passive thermal neutron detector has been used which consists of a CR-39 track detector facing a new type of boron-loaded radiator. Once calibrated, this passive detector has been used for the measurement of both the thermal neutron component and the cadmium ratio of different neutron spectra. In addition, bubble detectors with a response highly sensitive to thermal neutrons have also been used. Both thermal neutron detectors are simple to use, very compact and totally insensitive to low-ionizing radiation such as electrons and X-rays. The resultant thermal neutron flux was above 10(6) n/cm(2) s and the cadmium ratio was no greater than 15 for the first attempt of photo-conversion of X-ray radiotherapy beams. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:3656 / 3660
页数:5
相关论文
共 50 条
  • [41] An automated neutron dosimetry system based on the chemical etch of CR-39
    Harvey, JR
    French, AP
    Jackson, M
    Renouf, MC
    Weeks, AR
    RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 149 - 152
  • [43] Effect of γ rays on fast neutron registration in CR-39
    Kobzev, AP
    El-Asser, MR
    El-Halem, AA
    Abdul-Ghaphar, US
    Salama, TA
    RADIATION MEASUREMENTS, 2003, 37 (03) : 201 - 204
  • [44] Neutron dose comparison: CR-39 vs TLD
    Sengupta, S
    Holeman, G
    Kahnhauser, H
    HEALTH PHYSICS, 2002, 82 (06): : S122 - S122
  • [45] TRIALS AND TRIBULATIONS OF PROCESSING CR-39 FOR NEUTRON DOSIMETRY
    PARKHURST, MA
    HAGGARD, DL
    TOMERAASEN, PL
    HADLOCK, DE
    HEALTH PHYSICS, 1984, 47 (01): : 155 - 155
  • [46] Optimization of CR-39 for fast neutron dosimetry applications
    Vilela, E
    Fantuzzi, E
    Giacomelli, G
    Giorgini, M
    Morelli, B
    Patrizii, L
    Serra, P
    Togo, V
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 437 - 442
  • [47] Neutron dosimetry at low and high fluences with CR-39
    Meyer, P
    Groetz, JE
    Fromm, M
    Lacourt, A
    Chambaudet, A
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 423 - 428
  • [48] CR-39 PLASTIC AS A NEUTRON DOSIMETER FOR PERSONNEL MONITORING
    OSWALD, RA
    WHEELER, RV
    BENTON, EV
    HEALTH PHYSICS, 1979, 37 (06): : 844 - 844
  • [49] IMPROVEMENT ON CR-39 MANUFACTURING FOR NEUTRON DOSIMETRY APPLICATIONS
    LEMBO, L
    CIVOLANI, O
    PATRIZII, L
    LODI, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 633 - 636
  • [50] Optimization of CR-39 for fast neutron dosimetry applications
    Vilela, E.
    Fantuzzi, E.
    Giacomelli, G.
    Giorgini, M.
    Morelli, B.
    Patrizii, L.
    Serra, P.
    Togo, V.
    Radiation Measurements, 1999, 31 (01): : 437 - 442