Feasibility and reference values of left atrial longitudinal strain imaging by two-dimensional speckle tracking

被引:295
|
作者
Cameli, Matteo [2 ]
Caputo, Maria [2 ]
Mondillo, Sergio [2 ]
Ballo, Piercarlo [1 ]
Palmerini, Elisabetta [2 ]
Lisi, Matteo [2 ]
Marino, Enzo [3 ]
Galderisi, Maurizio [4 ]
机构
[1] S Andrea Hosp, Cardiol Operat Unit, La Spezia, Italy
[2] Univ Siena, Dept Cardiovasc Dis, I-53100 Siena, Italy
[3] GE Healthcare, Milan, Italy
[4] Federico II Univ Hosp, Cardioangiol Unit, CCU, Dept Clin & Expt Med, Naples, Italy
关键词
ECHOCARDIOGRAPHIC EVALUATION; DEFORMATION; QUANTIFICATION;
D O I
10.1186/1476-7120-7-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The role of speckle tracking in the assessment of left atrial (LA) deformation dynamics is not established. We sought to determine the feasibility and reference ranges of LA longitudinal strain indices measured by speckle tracking in a population of normal subjects. Methods: In 60 healthy individuals, peak atrial longitudinal strain (PALS) and time to peak longitudinal strain (TPLS) were measured using a 12-segment model for the left atrium. Values were obtained by averaging all segments (global PALS and TPLS) and by separately averaging segments measured in the two apical views (4- and 2-chamber average PALS and TPLS). Results: Adequate tracking quality was achieved in 97% of segments analyzed. Results: Adequate tracking quality was achieved in 97% of segments analyzed. Inter and intraobserver variability coefficients of measurements ranged between 2.9% and 5.4%. Global PALS was 42.2 +/- 6.1% (5-95 degrees percentile range 32.2-53.2%), and global TPLS was 368 +/- 30 ms (5-95 degrees percentile range 323-430 ms). The 2-chamber average PALS was slightly higher than the 4-chamber average PALS (44.3 +/- 6.0% vs 40.1 +/- 7.9%, p < 0.0001), whereas no differences in TPLS were found (p = 0.93). Conclusion: Speckle tracking is a feasible technique for the assessment of longitudinal myocardial LA deformation. Reference ranges of strain indices were reported.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Normal Left Ventricular Mechanics by Two-dimensional Speckle-tracking Echocardiography. Reference Values in Healthy Adults
    Kocabay, Gonenc
    Muraru, Denisa
    Peluso, Diletta
    Cucchini, Umberto
    Mihaila, Sorina
    Padayattil-Jose, Seena
    Gentian, Denas
    Iliceto, Sabino
    Vinereanu, Dragos
    Badano, Luigi P.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2014, 67 (08): : 651 - 658
  • [32] Right Ventricular Function in Preterm Neonates: Reference Values for Longitudinal Strain by Two-dimensional Speckle Tracking Echocardiography From Birth to One Year of Life
    Levy, Philip T.
    Patel, Meghna D.
    Holland, Mark R.
    Sekarski, Timothy J.
    Mathur, Amit
    Lee, Caroline
    Hamvas, Aaron
    Singh, Gautam K.
    CIRCULATION, 2015, 132
  • [33] Effects of Aging on Left Atrial Function Assessed by Two-Dimensional Speckle Tracking Echocardiography
    Okamatsu, Kyoko
    Takeuchi, Masaaki
    Nakai, Hiromi
    Nishikage, Tomoko
    Salgo, Ivan S.
    Husson, Stephane
    Otsuji, Yutaka
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) : 70 - 75
  • [34] Left atrial strain time integral evaluated by two-dimensional speckle tracking predicts left atrial appendage dysfunction in patients with acute ischemic stroke
    Takahata, Aoi
    Watanabe, Tetsu
    Wanezaki, Masahiro
    Nagai, Takayuki
    Edamura, Shunsuke
    Tsuchiya, Hayato
    Tamura, Harutoshi
    Nishiyama, Satoshi
    Otaki, Yoichiro
    Kutsuzawa, Daisuke
    Kato, Shigehiko
    Arimoto, Takanori
    Takahashi, Hiroki
    Watanabe, Masafumi
    HEART AND VESSELS, 2024, 39 (05) : 454 - 463
  • [35] Left atrial strain time integral evaluated by two-dimensional speckle tracking predicts left atrial appendage dysfunction in patients with acute ischemic stroke
    Aoi Takahata
    Tetsu Watanabe
    Masahiro Wanezaki
    Takayuki Nagai
    Shunsuke Edamura
    Hayato Tsuchiya
    Harutoshi Tamura
    Satoshi Nishiyama
    Yoichiro Otaki
    Daisuke Kutsuzawa
    Shigehiko Kato
    Takanori Arimoto
    Hiroki Takahashi
    Masafumi Watanabe
    Heart and Vessels, 2024, 39 : 454 - 463
  • [36] A systematic review and meta-analysis of the normal reference value of the longitudinal left atrial strain by three dimensional speckle tracking echocardiography
    Reza Mohseni-Badalabadi
    Tayebeh Mirjalili
    Arash Jalali
    Tahereh Davarpasand
    Ali Hosseinsabet
    Scientific Reports, 12
  • [37] A systematic review and meta-analysis of the normal reference value of the longitudinal left atrial strain by three dimensional speckle tracking echocardiography
    Mohseni-Badalabadi, Reza
    Mirjalili, Tayebeh
    Jalali, Arash
    Davarpasand, Tahereh
    Hosseinsabet, Ali
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [38] Quantitative analysis of left ventricular myocardial longitudinal layer-specific strain by two-dimensional speckle tracking echocardiography
    Li, Tianliang
    Zhang, Xiaoli
    Hu, Xinling
    Chen, Qingchang
    Han, Hong
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (16) : C173 - C173
  • [39] Left Atrial Functional Remodeling in Lone Atrial Fibrillation: A Two-Dimensional Speckle Tracking Echocardiographic Study
    Hong, Jin
    Gu, Xiaoyan
    An, Ping
    Luo, Taiyang
    Lv, Qiang
    Kang, Junping
    He, Yihua
    Hu, Rong
    Liu, Xiaohui
    Ma, Changsheng
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (09): : 1051 - 1060
  • [40] Normal Values and Reference Ranges for Left Atrial Strain by Speckle Tracking Echocardiography: The Copenhagen City Heart Study
    Nielsen, Anne B.
    Skaarup, Kristoffer G.
    Hauser, Raphael
    Johansen, Niklas D.
    Lassen, Mats H.
    Jensen, Gorm B.
    Schnohr, Peter
    Mogelvang, Rasmus
    Biering-Sorensen, Tor
    CIRCULATION, 2021, 144