Determination of ammonium by using a flow system with a diffusion cell coupled to an ammonium ion-selective sensor

被引:0
|
作者
Liu, RM
Sun, BT
机构
[1] CSIRO,DIV LAND & WATER RES,CANBERRA LAB,CANBERRA,ACT 2601,AUSTRALIA
[2] LIAOCHENG TEACHERS COLL,DEPT CHEM,SHANDONG,PEOPLES R CHINA
关键词
ammonium determination; potentiometry; ammonium electrode; gas diffusion;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a flow potentiometric method for determination of ammonium at low levels. A new diffusion cell coupled to an ammonium ion electrode was used as the potentiometric detector. This method eliminates interference to the ammonium ion electrode. When the stopped-flow method is employed for the acceptor stream, ammonium ions can be accumulated in the acceptor solution in the diffusion cell, giving high selectivity and sensitivity. The lower linear value of the proposed method can reach 1 x 10(-6) mol L-1 with an accumulation time of 5 min. The method is simple, sensitive and suitable for online determination of ammonium in water samples. It has been applied to the determination of ammonium in rain water and river water, and recoveries of 95-104% were obtained. The relative standard deviation of seven replicate analyses for all samples was 1.1-2.7%.
引用
收藏
页码:1255 / 1265
页数:11
相关论文
共 50 条
  • [11] A biosensor for the determination of ammonium ion using flow injection amperometric system
    Butmee, Preeyanut
    Prasertsri, Sarawut
    Pimmongkol, Saichol
    Tumcharern, Gamolwan
    Veseli, Albana
    Mehmeti, Eda
    Kalcher, Kurt
    Samphao, Anchalee
    MONATSHEFTE FUR CHEMIE, 2017, 148 (04): : 635 - 644
  • [12] Ion-selective electrodes for determination of organic ammonium ions: Ways for selectivity control
    Egorov, Vladimir V.
    Bolotin, Alexander A.
    TALANTA, 2006, 70 (05) : 1107 - 1116
  • [13] Intracellular measurement of ammonium in Chara corallina using ion-selective microelectrodes
    Wells, DM
    Miller, AJ
    PLANT AND SOIL, 2000, 221 (01) : 103 - 106
  • [14] Intracellular measurement of ammonium in Chara corallina using ion-selective microelectrodes
    Darren M. Wells
    Anthony J. Miller
    Plant and Soil, 2000, 221 : 103 - 106
  • [16] DESIGN AND CHARACTERIZATION OF A NOVEL AMMONIUM ION-SELECTIVE OPTICAL SENSOR BASED ON NEUTRAL IONOPHORES
    SEILER, K
    MORF, WE
    RUSTERHOLZ, B
    SIMON, W
    ANALYTICAL SCIENCES, 1989, 5 (05) : 557 - 561
  • [17] Potentiometry of Anionic Polyelectrolytes by Quaternary Ammonium Ion-Selective Electrode with Quaternary Ammonium Ion Added as Probe
    Zheng, Xiang-Yang
    Yano, Daisaku
    Yasui, Takashi
    Takada, Kazutake
    Yuchi, Akio
    ELECTROANALYSIS, 2009, 21 (17-18) : 2004 - 2009
  • [18] DETECTION AND AUTOMATIC-CONTROL OF AMMONIUM ION CONCENTRATION IN MICROBIAL CULTURE WITH AN AMMONIUM ION-SELECTIVE ELECTRODE
    SUZUKI, T
    YASUDA, T
    YAMANE, T
    SHIMIZU, S
    JOURNAL OF FERMENTATION TECHNOLOGY, 1986, 64 (01): : 63 - 70
  • [19] Gas diffusion techniques coupled sequential injection analysis for selective determination of ammonium
    Oms, MT
    Cerda, A
    Cladera, A
    Cerda, V
    Forteza, R
    ANALYTICA CHIMICA ACTA, 1996, 318 (03) : 251 - 260
  • [20] Flow spectrophotometric determination of ammonium ion
    Icardo, MC
    Torro, IG
    Zamora, LL
    Calatayud, JM
    ANALYTICA CHIMICA ACTA, 1999, 398 (2-3) : 311 - 318