A comparison of radiological and computer navigation measurements of lower limb coronal alignment before and after total knee replacement

被引:43
|
作者
Willcox, N. M. J.
Clarke, J. V. [1 ]
Smith, B. R. K. [1 ]
Deakin, A. H. [1 ]
Deep, K. [1 ]
机构
[1] Golden Jubilee Natl Hosp, Dept Orthopaed, Clydebank G81 4DY, W Dunbartonshir, England
来源
关键词
FIXED FLEXION DEFORMITY; AXIAL ALIGNMENT; RADIOGRAPHIC MEASURES; ASSISTED NAVIGATION; LEG RADIOGRAPH; ARTHROPLASTY; OSTEOARTHRITIS; ROTATION; PRECISION; SURGERY;
D O I
10.1302/0301-620X.94B9.28250
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared lower limb coronal alignment measurements obtained pre- and post-operatively with long-leg radiographs and computer navigation in patients undergoing primary total knee replacement (TKR). A series of 185 patients had their pre- and post-implant radiological and computer-navigation system measurements of coronal alignment compared using the Bland-Altman method. The study included 81 men and 104 women with a mean age of 68.5 years (32 to 87) and a mean body mass index of 31.7 kg/m(2) (19 to 49). Pre-implant Bland-Altman limits of agreement were -9.4 degrees to 8.6 degrees with a repeatability coefficient of 9.0 degrees. The Bland-Altman plot showed a tendency for the radiological measurement to indicate a higher level of pre-operative deformity than the corresponding navigation measurement. Post-implant limits of agreement were -5.0 degrees to 5.4 degrees with a repeatability coefficient of 5.2 degrees. The tendency for valgus knees to have greater deformity on the radiograph was still seen, but was weaker for varus knees. The alignment seen or measured intra-operatively during TKR is not necessarily the same as the deformity seen on a standing long-leg radiograph either pre- or post-operatively. Further investigation into the effect of weight-bearing and surgical exposure of the joint on the mechanical femorotibial angle is required to enable the most appropriate intra-operative alignment to be selected.
引用
收藏
页码:1234 / 1240
页数:7
相关论文
共 50 条
  • [31] Computer navigation of soft tissues in total knee replacement: optimizing knee kinematics
    Kamat, Yogeesh D.
    Aurakzai, Kamran M.
    Field, Richard E.
    Adhikari, Ajeya R.
    CURRENT ORTHOPAEDIC PRACTICE, 2010, 21 (06): : 595 - 599
  • [32] Effect of the Extent of Release for Knee Balancing on Post-Operative Limb Coronal Alignment After Primary Total Knee Arthroplasty
    Alzahrani, Mohammad M.
    Wood, Thomas J.
    Somerville, Lyndsay E.
    MacDonald, Steven J.
    Howard, James L.
    Vasarhelyi, Edward M.
    Lanting, Brent A.
    ORTHOPEDIC RESEARCH AND REVIEWS, 2020, 12 : 113 - 119
  • [33] No effect of obesity on limb and component alignment after computer-assisted total knee arthroplasty
    Shetty, Gautam M.
    Mullaji, Arun B.
    Bhayde, Sagar
    Lingaraju, A. P.
    KNEE, 2014, 21 (04): : 862 - 865
  • [34] Coronal plane stability before and after total knee arthroplasty
    Siston, Robert A.
    Goodman, Stuart B.
    Delp, Scott L.
    Giori, Nicholas J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) : 43 - 49
  • [35] An analysis of intra-operative variation in femorotibial alignment in the coronal plane during computer navigated total knee replacement
    Mohanlal, Paraskumar
    Jain, Sunil
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (02): : 233 - 236
  • [36] Quantitative measurement of lower limb mechanical alignment and coronal knee laxity in early flexion
    Russell, David F.
    Deakin, Angela H.
    Fogg, Quentin A.
    Picard, Frederic
    KNEE, 2014, 21 (06): : 1063 - 1068
  • [37] Measurement of rotational and coronal alignment in total knee arthroplasty using a navigation system is reproducible
    Keizo Wada
    Hiroshi Mikami
    Daisuke Hamada
    Hiroshi Yonezu
    Koichi Oba
    Koichi Sairyo
    Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 271 - 276
  • [38] Measurement of rotational and coronal alignment in total knee arthroplasty using a navigation system is reproducible
    Wada, Keizo
    Mikami, Hiroshi
    Hamada, Daisuke
    Yonezu, Hiroshi
    Oba, Koichi
    Sairyo, Koichi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (02) : 271 - 276
  • [39] BIOMECHANICAL INDICES OF STANDING AND GAIT IN PATIENTS AFTER TOTAL KNEE REPLACEMENT USING COMPUTER NAVIGATION
    Bezgodkov, Yu. A.
    Kornilov, N. N.
    Petukhov, A. I.
    Kulyaba, T. A.
    Selin, A. V.
    Muranchic, Yu. I.
    Croitoru, I. I.
    Ignatenko, V. L.
    Saraev, A. V.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2011, (04): : 11 - 17
  • [40] Radiological Approach to Assessment of Lower-Limb Alignment-Coronal and Transverse Plane Analysis
    Michalska-Foryszewska, Anna
    Modzelewski, Piotr
    Sklinda, Katarzyna
    Mruk, Bartosz
    Walecki, Jerzy
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (22)