A new parallel-plate graphite ionization chamber as a 60Co gamma radiation reference instrument

被引:8
|
作者
Perini, Ana P. [1 ]
Neves, Lucio P. [1 ]
Fernandez-Varea, Jose M. [2 ,3 ]
Cassola, Vagner F. [4 ]
Kramer, Richard [4 ]
Khoury, Helen J. [4 ]
Caldas, Linda V. E. [1 ]
机构
[1] Comissao Nacl Energia Nucl IPEN CNEN SP, Inst Pesquisas Energet & Nucl, BR-05508000 Rio De Janeiro, SP, Brazil
[2] Univ Barcelona, Fac Fis, ECM, E-08028 Barcelona, Spain
[3] Univ Barcelona, Fac Fis, ICC, E-08028 Barcelona, Spain
[4] Univ Fed Pernambuco, Dept Energia Nucl, BR-50740540 Recife, PE, Brazil
基金
巴西圣保罗研究基金会;
关键词
Graphite ionization chamber; Reference system; Gamma radiation; Monte Carlo simulation; AIR-KERMA; STANDARD;
D O I
10.1016/j.radphyschem.2013.01.005
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The calibration procedure in radiotherapy treatments is very important and a sensitive task due to the high doses delivered to the patients. Generally, the air-kerma cavity standards for Co-60 gamma rays are graphite cavity ionization chambers. In this work a new parallel-plate graphite ionization chamber was studied to analyze its potential use as a reference instrument. In order to evaluate its performance in Co-60 beams, it was submitted to several characterization tests. Moreover, Monte Carlo simulations were undertaken using the EGSnrc code to study the influence of the chamber components on its response. The results obtained showed that this new ionization chamber presented a satisfactory performance in all evaluated tests. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:106 / 108
页数:3
相关论文
共 50 条
  • [41] Comparison of the Characteristics of Two Types of Parallel-plate Ionization Chamber Under Small-field Electron Irradiation
    Yanagi, Yuya
    Monzen, Hajime
    Kubo, Kazuki
    Sugiyama, Junko
    Noma, Kazuo
    Ito, Takaaki
    Sakai, Yusuke
    Nakamura, Kenji
    Kida, Tetsuo
    Doi, Hiroshi
    Nishimura, Yasumasa
    ANTICANCER RESEARCH, 2023, 43 (05) : 1967 - 1972
  • [42] Analysis of Dose Perturbation Factors for An NACP-02 Parallel-Plate Ionization Chamber in Clinical Electron Beams
    Chin, E.
    Seuntjens, J.
    Bailey, M.
    Shipley, D.
    Palmans, H.
    Dusautoy, A.
    Verhaegen, F.
    MEDICAL PHYSICS, 2008, 35 (06) : 2953 - +
  • [43] Comparison of the standards for air kerma of the VNIIM and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Oborin, A. V.
    Villevalde, A. Y.
    METROLOGIA, 2011, 48
  • [44] Transformations of Imidazolium Ionic Liquids under the Influence of 60Co Gamma Radiation
    Tarasova, N. P.
    Zanin, A. A.
    Krivoborodov, E. G.
    DOKLADY PHYSICAL CHEMISTRY, 2022, 503 (02) : 39 - 44
  • [45] 60Co Gamma Radiation Promoted Oxidation in Zinc Nitride Thin Films
    Sivakumar, P.
    Peranantham, P.
    Sivakumar, V. V.
    Asokan, K.
    Jeyachandran, Y. L.
    DAE SOLID STATE PHYSICS SYMPOSIUM 2019, 2020, 2265
  • [46] TL response of Sm-doped MgO to 60Co gamma radiation
    Gonzalez, P. R.
    Mendoza-Anaya, D.
    Escobar-Alarcon, L.
    Avila, O.
    APPLIED RADIATION AND ISOTOPES, 2024, 214
  • [47] Comparison of the standards for air kerma of the NRC and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    McCaffrey, J. P.
    Ross, C. K.
    METROLOGIA, 2010, 47
  • [48] 60Co gamma radiation effect on AlGaN/AlN/GaN HEMT devices
    Wang Yan-Ping
    Luo Yin-Hong
    Wang Wei
    Zhang Ke-Ying
    Guo Hong-Xia
    Guo Xiao-Qiang
    Wang Yuan-Ming
    CHINESE PHYSICS C, 2013, 37 (05)
  • [49] 60Co gamma radiation effect on AlGaN/AlN/GaN HEMT devices
    王燕萍
    罗尹虹
    王伟
    张科营
    郭红霞
    郭晓强
    王园明
    Chinese Physics C, 2013, (05) : 56 - 61
  • [50] Comparison of the standards for air kerma of the ARPANSA and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Lye, J.
    Oliver, C.
    METROLOGIA, 2011, 48