Effect of Continuous-Flow Mechanical Circulatory Support on Microvasculature Remodeling in the Failing Heart

被引:10
|
作者
Saito, Tetsuya [1 ]
Miyagawa, Shigeru [1 ]
Toda, Koichi [1 ]
Yoshikawa, Yasushi [1 ]
Fukushima, Satsuki [1 ]
Saito, Shunsuke [1 ]
Yoshioka, Daisuke [1 ]
Sakata, Yasushi [2 ]
Daimon, Takashi [3 ]
Sawa, Yoshiki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Cardiovasc Surg, Suita, Osaka, Japan
[2] Osaka Univ, Dept Cardiol, Grad Sch Med, Suita, Osaka, Japan
[3] Hyogo Coll Med, Dept Biostat, Nishinomiya, Hyogo, Japan
基金
日本学术振兴会;
关键词
Continuous-flow LVAD; Left ventricular assist device; Mechanical unloading; Pulsatility; Reverse remodelling; Microvasculature; Smooth muscle cell; VENTRICULAR ASSIST DEVICES; INTERNATIONAL-SOCIETY; DESTINATION THERAPY; PULSATILE-FLOW; PRESSURE; RECOVERY; TRANSPLANTATION; RESPONSES; OUTCOMES; FAILURE;
D O I
10.1111/aor.13348
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Left ventricle (LV) unloading caused by a left ventricular assist device (LVAD) has been shown to enhance reverse LV remodeling in end-stage cardiomyopathy. Several reports consistently suggest that a pulsatile-flow LVAD has more profound effects compared to continuous-flow LVAD, though the responsible mechanisms are not fully understood. We hypothesized that arterial pulsatility, being affected by the type of LVAD, may affect microvasculature and functional/pathological LV remodeling in end-stage cardiomyopathy. The study included 18 patients with chronic heart failure who underwent LVAD implantation. Eight patients were implanted with pulsatile-flow LVAD, and 10 patients were implanted with continuous-flow LVAD. The results of serial echocardiograms and histopathological assessment of transmural LV tissues, which were collected during the implantation and removal of LVADs, were compared between the groups. The results of echocardiography showed that LV systolic dimension and LV ejection fraction improved greatly in the pulsatile-flow LVAD group compared to the continuous-flow LVAD group. Histological analysis showed that in both groups, increased microvasculature density and decreased cardiomyocyte size during LVAD support had no significant difference. In contrast, only the patients with continuous-flow LVADs had presented with significant increase in -smooth muscle actin (-SMA)-positive layer thickness and the number of proliferating cell nuclear antigen (PCNA)-positive cells of myocardial arterioles. We concluded that the use of long-term continuous-flow LVAD support, having less pulsatility, had induced more thickening to the medial layer of myocardial arterioles compared to the use of pulsatile-flow LVADs. Our findings suggest that the pathological impairment of myocardial microvascular structure during continuous-flow LVAD support may be a novel mechanism which accounts for the difference in LV remodeling depending on the type of LVAD.
引用
收藏
页码:350 / 362
页数:13
相关论文
共 50 条
  • [41] SURGICAL AND MECHANICAL SUPPORT OF THE FAILING HEART
    TURINA, M
    EUROPEAN HEART JOURNAL, 1983, 4 : 211 - 217
  • [42] An Extended Role of Continuous Flow Device in Pediatric Mechanical Circulatory Support
    Peng, Ed
    Kirk, Richard
    Wrightson, Neil
    Phuoc Duong
    Ferguson, Lee
    Griselli, Massimo
    Butt, Tanveer
    O'Sullivan, John J.
    MacGowan, Guy A.
    Crossland, David
    Schueler, Stephan
    Hasan, Asif
    ANNALS OF THORACIC SURGERY, 2016, 102 (02): : 620 - 627
  • [43] Modulation of the acquired VWF defect by arterial pulsatility in continuous-flow mechanical circulatory devices
    Vincent, F.
    Rauch, A.
    Loobuyck, V.
    Nix, C.
    Vincentelli, A.
    Leprince, P.
    Smadja, D.
    Jansen, P.
    Debry, N.
    Moussa, M.
    Carpentier, A.
    Spillemaeker, H.
    Lenting, P.
    Susen, S.
    Van Belle, E.
    EUROPEAN HEART JOURNAL, 2018, 39 : 535 - 535
  • [44] A unique case of driveline fracture In a continuous-flow mechanical support device
    Loforte, Antonio
    Della Monica, Paola Lilla
    Musumeci, Francesco
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (08): : 967 - 968
  • [45] Left Ventricular Ejection Fraction Under Continuous-Flow Mechanical Support
    Jain, Pankaj
    Hayward, Christopher S.
    CIRCULATION-HEART FAILURE, 2020, 13 (09) : E007427
  • [46] Forward-thinking design solutions for mechanical circulatory support: multifunctional hybrid continuous-flow ventricular assist device technology
    Throckmorton, Amy
    Garven, Ellen
    Hirschhorn, Matthew
    Day, Steven
    Stevens, Randy
    Tchantchaleishvili, Vakhtang
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (03) : 383 - 385
  • [47] Effect of mechanical circulatory support on outcomes after heart transplantation
    Drakos, SG
    Kfoury, AG
    Long, JW
    Stringham, JC
    Gilbert, EM
    Moore, SA
    Campbell, BK
    Nelson, KE
    Horne, BD
    Renlund, DG
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (01): : 22 - 28
  • [48] Coronary Artery Remodeling and Fibrosis With Continuous-Flow Left Ventricular Assist Device Support
    Ambardekar, Amrut V.
    Weiser-Evans, Mary C. M.
    Li, Marcella
    Purohit, Suneet N.
    Aftab, Muhammad
    Reece, T. Brett
    Moulton, Karen S.
    CIRCULATION-HEART FAILURE, 2018, 11 (05) : e004491
  • [49] Coronary Artery Remodeling and Fibrosis with Continuous-Flow Left Ventricular Assist Device Support
    Ambardekar, A. V.
    Weiser-Evans, M.
    Li, M.
    Aftab, M.
    Reece, T.
    Buttrick, P.
    Moulton, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S127 - S127
  • [50] Heart transplantation and mechanical circulatory support
    Om Prakash Yadava
    Vivek Rao
    Indian Journal of Thoracic and Cardiovascular Surgery, 2020, 36 : 299 - 300