Determination of silicon in biomass and products of pyrolysis process via high-resolution continuum source atomic absorption spectrometry

被引:12
|
作者
Nakadi, Flavio V. [1 ]
Prodanov, Caroline [1 ]
Boschetti, Wiliam [1 ]
Vale, Maria Goreti R. [1 ,2 ]
Welz, Bernhard [2 ,3 ]
de Andrade, Jailson B. [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, Porto Alegre, RS, Brazil
[2] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
[3] Univ Fed Santa Catarina, Dept Quim, Florianopolis, SC, Brazil
关键词
Biomass; Bio-oil; Silicon determination; High-resolution continuum source atomic absorption spectrometry; Mass balance; SEQUENTIAL MULTIELEMENT DETERMINATION; OPTICAL-EMISSION SPECTROMETRY; SOLID SAMPLE ANALYSIS; LANDFILL GAS; BIO-OILS; GF AAS; ELEMENTS; SI; IDENTIFICATION; COMBUSTION;
D O I
10.1016/j.talanta.2017.12.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thermochemical processes can convert the biomass into fuels, such as bio-oil. The biomass submitted to pyrolysis process, such as fibers, are generally rich in silicon, an element that can lead to damages in an engine when there is high concentration in a fuel. High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is an interesting alternative for Si determination in the products and byproducts of the pyrolysis process because, besides the flame (F) and graphite furnace (GF) atomizers, it has enhanced the application of direct analysis of solid samples (SS) within GF. This study aimed the development of methods to determine Si in biomass samples, their products and byproducts using HR-CS AAS. A high-resolution continuum source atomic absorption spectrometer contrAA 700 equipped with F and GF atomizers was used throughout the study. HR-CS F AAS (lambda = 251.611 nm, 1 detection pixel, N2O/C2H2 flame) was used to evaluate Si content in biomass and ash, after a microwave-assisted acid digestion with HNO3 and HF. HR-CS GF AAS (T-pyr = 1400 degrees C, T-atom = 2650 degrees C) has evaluated Si in pyrolysis water and bio-oil at 251.611 nm, and in peach pit biomass and ash at 221.174 nm using SS, both wavelengths with 1 detection pixel. Rhodium (300 mu g) was applied as permanent modifier and 10 mu g Pd + 6 mu g Mg were pipetted onto the standards/samples at each analysis. Three different biomass samples were studied: palm tree fiber, coconut fiber and peach pit, and three certified reference materials (CRM) were used to verify the accuracy of the methods. The figures of merit were LOD 0.09-20 mg kg(-1), and LOQ 0.3-20 mg kg(-1), considering all the methods. There were no significant differences between the CRM certified values and the determined ones, using a Student t-test with a confidence interval of 95% (n = 5). Si concentration ranged from 0.11-0.92% m m(-1), 1.1-1.7 mg kg(-1), 3.3-13 mg kg(-1), and 0.41-1.4% m m(-1), in biomass, bio-oil, pyrolysis water and ash, respectively. Si remained mostly in the ash, leading to a mass fraction of up to 103%, even when the Si loss is not considered. Silicon concentration in bio-oil was below 1.7 mg kg(-1), which is suitable for its application as a fuel. The developed methods using HR-CS AAS are suitable for Si determination in biomass, bio-oil, pyrolysis water, and ash. The application of bio-oil as an alternative fuel would be possible evaluating its Si content due to its low levels. The mass balance for Si has proved to be an important tool in order to evaluate the correct disposal of pyrolysis process byproducts.
引用
收藏
页码:828 / 835
页数:8
相关论文
共 50 条
  • [41] High-resolution continuum-source atomic absorption spectrometry - What can we expect?
    Welz, B
    Becker-Ross, H
    Florek, S
    Heitmann, U
    Vale, MGR
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2003, 14 (02) : 220 - 229
  • [42] Investigation of phosphorus atomization using high-resolution continuum source electrothermal atomic absorption spectrometry
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Lepri, Fabio G.
    Welz, Bernhard
    Heitmann, Uwe
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (05) : 429 - 434
  • [43] High-resolution continuum source graphite furnace atomic absorption spectrometry for the monitoring of Au nanoparticles
    Resano, Martín (mresano@unizar.es), 1600, Royal Society of Chemistry (31):
  • [44] Determination of fluorine in milk and water via molecular absorption of barium monofluoride by high-resolution continuum source atomic absorption spectrometer
    Ozbek, Nil
    Akman, Suleyman
    MICROCHEMICAL JOURNAL, 2014, 117 : 111 - 115
  • [45] Method development for the determination of bromine via molecular absorption of barium monobromide by high-resolution continuum source molecular absorption spectrometry
    Turhan, Neslihan
    Ozbek, Nil
    Akman, Suleyman
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (03) : 577 - 582
  • [46] Application of High-Resolution Continuum Source Molecular Absorption Spectrometry for the Determination of Nitrite and Nitrate Nitrogen
    Nemecek, Martin
    Machynak, L'Ubomir
    Beinrohr, Ernest
    Cacho, Frantisek
    Horvath, Patrik
    CHEMICKE LISTY, 2017, 111 (09): : 588 - 590
  • [47] Determination of bromine using high-resolution continuum source molecular absorption spectrometry in a graphite furnace
    Limburg, Tobias
    Einax, Jurgen W.
    MICROCHEMICAL JOURNAL, 2013, 107 : 31 - 36
  • [48] Validation of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Determination of Selected Toxic Metals in the Decontamination Process of Wastewater Discharged in Natural Receivers
    Senna, Bame Sanah
    Masamba, Wellington
    Obuseng, Veronica
    Frentiu, Tiberiu
    Angyus, Bogdan Simion
    Covaci, Eniko
    ACTA CHIMICA SLOVENICA, 2024, 71 (03) : 500 - 508
  • [49] Determination of aluminum in highly concentrated iron samples: Study of interferences using high-resolution continuum source atomic absorption spectrometry
    Bohrer, Denise
    Heitmann, Uwe
    Huang, Mao-Dong
    Becker-Ross, Helmut
    Florek, Stefan
    Welz, Bemhard
    Bertagnolli, Denise
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (09) : 1012 - 1018
  • [50] Fast sequential determination of antimony and lead in pewter alloys using high-resolution continuum source flame atomic absorption spectrometry
    Dessuy, Morgana B.
    de Jesus, Robson M.
    Brandao, Geovani C.
    Ferreira, Sergio L. C.
    Vale, Maria Goreti R.
    Welz, Bernhard
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2013, 30 (01): : 202 - 207