Validity of segmental multiple-frequency bioelectrical impedance analysis to estimate body composition of adults across a range of body mass indexes

被引:181
|
作者
Shafer, Kimberly J. [1 ]
Siders, William A. [1 ]
Johnson, LuAnn K. [1 ]
Lukaski, Henry C. [1 ]
机构
[1] USDA, Grand Forks Human Nutr Res Ctr, Grand Forks, ND USA
关键词
Bioelectrical impedance analysis; Body composition; Body mass index; Dual x-ray absorptiometry; X-RAY ABSORPTIOMETRY; CROSS-CALIBRATION; OBESE; FAT; ACCURACY; OVERWEIGHT; PREVENTION; RISK; DXA;
D O I
10.1016/j.nut.2008.07.004
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: We compared body composition estimates using an eight-electrode, segmental, multiple-frequency bioelectrical impedance analysis (segmental MF-BIA) and dual x-ray absorptiometry (DXA) in a group of healthy adults with a range of body mass indexes (BMIs). Methods: Percentage of body fat (%BF), fat-free mass, and fat mass assessed by DXA and segmental MF-BIA in 132 healthy adults were classified by normal (N; 18.5-24.9 kg/m(2)), overweight (OW; 25-29.9 kg/m(2)), and obese (OB; 30-39.9 kg/m(2)) BMI. Results: Compared with DXA, segmental MF-BIA overestimated %BF in the OB BMI group (3.4%; P < 0.0001). MF-BIA overestimated %BF among men (0.75%; P < 0.006) and women (0.87%; P < 0.006) and underestimated it in the N BMI group (-1.56%; P < 0.0001); %BF was not different between methods in the OW BMI group. Error in %BF determined by segmental MF-BIA and DXA increased as %BF increased (r = 0.42, P < 0.0001). Waist circumference was the only significant predictor of systematic error in %BF between MF-BIA and DXA (r = 0.60, P < 0.0001). Conclusion: Eight-electrode, segmental MF-BIA is a valid method to estimate %BF in adults with BMI classified as N and OW, but not as OB. Estimation of trunk resistance with current segmental MF-BIA devices may explain the underestimation of %BF in the adults with OB BMI. Further examination of the effect of waist circumference and body fat distribution on the accuracy of BIA measurements is warranted. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [41] Changes over time in body composition assessed by segmental bioelectrical impedance analysis in COPD patients
    Gologanu, Daniela
    Ionita, Diana
    Stanescu, Cristina
    Raceanu, Ana Maria
    Bogdan, Miron Alexandru
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [42] Validity of total and segmental impedance measurements for prediction of body composition across ethnic population groups
    P Deurenberg
    M Deurenberg-Yap
    FJM Schouten
    European Journal of Clinical Nutrition, 2002, 56 : 214 - 220
  • [43] Evaluation Of A Bioelectrical Impedance Device In The Analysis Of Body Composition
    Gogain, Melissa
    Schoffstall, James
    McLaughlin, James
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 317 - 317
  • [44] Evaluation Of A Bioelectrical Impedance Device In The Analysis Of Body Composition
    Gogain, Melissa
    Schoffstall, James
    McLaughlin, James
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2012, 27 : 317 - 317
  • [45] Bioelectrical Impedance Analysis and Body Composition in Cardiovascular Diseases
    Popiolek-Kalisz, Joanna
    Szczygiel, Karolina
    CURRENT PROBLEMS IN CARDIOLOGY, 2023, 48 (11)
  • [46] Accuracy of Multi-frequency Bioelectrical Impedance to Determine Segmental Lean Body Mass in Young Women
    Miller, Daniel R.
    Masteller, Brittany
    Dixon, Curt B.
    Andreacci, Joseph L.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 618 - 618
  • [47] Effect of peritoneal fluid on whole body and segmental multiple frequency bioelectrical impedance in patients on peritoneal dialysis
    N Than
    G Woodrow
    B Oldroyd
    C Gonzalez
    JH Turney
    AM Brownjohn
    European Journal of Clinical Nutrition, 2000, 54 : 450 - 451
  • [48] Effect of peritoneal fluid on whole body and segmental multiple frequency bioelectrical impedance in patients an peritoneal dialysis
    Than, N
    Woodrow, G
    Oldroyd, B
    Gonzalez, C
    Turney, JH
    Brownjohn, AM
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2000, 54 (05) : 450 - 451
  • [49] Determination of Body Fat Mass: Bioelectrical Impedance Analysis
    Safer, Umut
    Safer, Vildan Binay
    Cintosun, Umit
    JOURNAL OF ARTHROPLASTY, 2015, 30 (05): : 895 - 896
  • [50] Body Fat Proportion Estimation by the Segmental Bioelectrical Impedance Analysis of Forearm
    Metshein, Margus
    Tuulik, Varje-Riin
    Tuulik, Viiu
    Min, Mart
    Kumm, Monika
    Annus, Paul
    Martens, Olev
    2024 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2024, 2024,