The gas hold-up in bubble columns. I. The influence of hydrodynamic conditions

被引:0
|
作者
Pincovschi, I
Mihai, M
机构
[1] Univ Politehn Bucuresti, Fac Energet, Bucharest, Romania
[2] Univ Politehn Bucuresti, Fac Chim Ind, Bucharest 011061, Romania
来源
REVISTA DE CHIMIE | 2004年 / 55卷 / 02期
关键词
gas hold-up; bubble; dispersed system; homogenous and heterogenous flow regime;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
There are several methods to perform experimental measurements of the overall gas hold-up in bubble columns but none of them is considered to be a standard method for measuring this parameter The precision of measurements lies between 10-20%, and improvements to increase it for any of these methods are welcomed. This work presents improvements to liquid height variation method. Experimental measurements of gas hold-lip in a bubble column are correlated with flow regimes and bubble size distribution in a bubble column with porous plate gas distribution device.
引用
收藏
页码:126 / 129
页数:4
相关论文
共 50 条
  • [31] Influence of Liquid Flow on Gas Hold-up in Bubble Column.
    Kawalec-Peitrenko, Bozena
    Inzynieria Chemiczna i Procesowa, 1986, 7 (01): : 173 - 178
  • [32] EFFECT OF WOOD PULP FIBER CONCENTRATION ON GAS HOLD-UP IN BUBBLE-COLUMNS
    WENT, J
    JAMIALAHMADI, M
    MULLERSTEINHAGEN, H
    CHEMIE INGENIEUR TECHNIK, 1993, 65 (03) : 306 - 308
  • [33] Measurement of gas hold-up in bubble columns from low frequency acoustic emissions
    Boyd, J.W.R. (j.boyd@ic.ac.uk), 1600, Elsevier (88): : 1 - 3
  • [34] GAS HOLD-UP AND MASS-TRANSFER IN BUBBLE-COLUMNS WITH PSEUDOPLASTIC LIQUIDS
    VATAI, G
    TEKIC, MN
    CHEMICAL ENGINEERING SCIENCE, 1989, 44 (10) : 2402 - 2407
  • [35] Gamma ray tomography - An experimental analysis of fractional gas hold-up in bubble columns
    Patel, Ashutosh K.
    Thorat, Bhaskar N.
    CHEMICAL ENGINEERING JOURNAL, 2008, 137 (02) : 376 - 385
  • [36] GAS HOLD-UP AND MASS-TRANSFER CHARACTERISTICS OF PACKED BUBBLE-COLUMNS
    SAWANT, SB
    PANGARKAR, VG
    JOSHI, JB
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1979, 18 (02): : 143 - 149
  • [37] Measurement of gas hold-up in bubble columns from low frequency acoustic emissions
    Boyd, JWR
    Varley, J
    CHEMICAL ENGINEERING JOURNAL, 2002, 88 (1-3) : 111 - 118
  • [38] Gas hold-up, liquid circulation and gas-liquid mass transfer in slurry bubble columns
    Gavroy, D.
    Joly-Vuillemin, C.
    Cordier, G.
    Delmas, H.
    Chemical Engineering Research and Design, 1995, 73 (A6) : 637 - 642
  • [39] MIXING CHARACTERISTICS AND GAS HOLD-UP OF A BUBBLE COLUMN
    GUY, C
    CARREAU, PJ
    PARIS, J
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1986, 64 (01): : 23 - 35
  • [40] Effect of sparger design and height to diameter ratio on fractional gas hold-up in bubble columns
    Thorat, BN
    Shevade, AV
    Bhilegaonkar, KN
    Aglawe, RH
    Veera, UP
    Thakre, SS
    Pandit, AB
    Sawant, SB
    Joshi, JB
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1998, 76 (A7): : 823 - 834