An amperometric sensor based on ionic liquid and carbon nanotube modified composite electrode for the determination of nitrite in milk

被引:97
|
作者
Zhou, Ling [1 ]
Wang, Jian-Ping [1 ]
Gai, Ling [1 ]
Li, Du-Juan [1 ]
Li, Yan-Bin [1 ,2 ]
机构
[1] Zhejiang Univ, Coll Biosyst Engn & Food Sci, Hangzhou 310058, Zhejiang, Peoples R China
[2] Univ Arkansas, Dept Biol & Agr Engn, Fayetteville, AR 72701 USA
来源
关键词
Nitrite; Ionic liquid; Carbon nanotube; Composite electrode; Milk samples; ELECTROCATALYTIC REDUCTION; NITRATE; WATER; OXIDATION; CHEMILUMINESCENCE; NANOPARTICLES; PROPERTY; BEHAVIOR; SAMPLES; FILM;
D O I
10.1016/j.snb.2013.02.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel carbon composite electrode has been fabricated using ionic liquid n-octylpyridinum hexafluorophosphate (OPFP) and single-walled carbon nanotube (SWCNT). This electrode combined the advantages of ionic liquid and SWCNT as well as the characteristics of the "bulk" composite electrodes. Compared with the commercial glassy carbon electrode (GCE) and the ionic liquid-graphite (IL-G) composite electrode, the ionic liquid-SWCNT (IL-SWCNT) composite electrode exhibited remarkable increase in the electron transfer rate for electroactive compound and significant decrease in the overpotential for the oxidation of nitrite. Based on the enhanced electrocatalytic activity for the oxidation of nitrite, a wide linear range from 1.0 mu M to 12.0 mM with a low detection limit of 0.1 mu M was obtained. Furthermore, the IL-SWCNT electrode was applied to determine nitrite levels in milk samples. Experimental results showed that the proposed electrode could be used as an effective and sensitive sensor for the determination of nitrite. Crown Copyright (C) 2013 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 70
页数:6
相关论文
共 50 条
  • [41] A novel amperometric sensor based on intercalated montmorillonite modified carbon paste electrode for hydroquinone determination
    Kong, Yong
    Ma, Mengjie
    Mao, Huihui
    Ma, Jiangquan
    Yao, Chao
    ANALYTICAL METHODS, 2012, 4 (03) : 748 - 752
  • [42] Direct proteins electrochemistry based on ionic liquid mediated carbon nanotube modified glassy carbon electrode
    Zhao, Q
    Zhan, DP
    Ma, HY
    Zhang, MQ
    Zhao, YF
    Jing, P
    Zhu, ZW
    Wan, XH
    Shao, YH
    Zhuang, QK
    FRONTIERS IN BIOSCIENCE, 2005, 10 : 326 - 334
  • [43] Amperometric nitrite sensor based on a glassy carbon electrode modified with multi-walled carbon nanotubes and poly(toluidine blue)
    Juan Dai
    Dongli Deng
    Yali Yuan
    Jinzhong Zhang
    Fei Deng
    Shuang He
    Microchimica Acta, 2016, 183 : 1553 - 1561
  • [44] Amperometric nitrite sensor based on a glassy carbon electrode modified with multi-walled carbon nanotubes and poly(toluidine blue)
    Dai, Juan
    Deng, Dongli
    Yuan, Yali
    Zhang, Jinzhong
    Deng, Fei
    He, Shuang
    MICROCHIMICA ACTA, 2016, 183 (05) : 1553 - 1561
  • [45] Electrochemical Oxidation and Amperometric Determination of Isoniazid at Functionalized Multiwalled Carbon Nanotube Modified Electrode
    Chen, Wan-Chun
    Unnikrishnan, Binesh
    Chen, Shen-Ming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (10): : 9138 - 9149
  • [46] Methylene Blue/Multiwall Carbon Nanotube Modified Electrode for the Amperometric Determination of Hydrogen Peroxide
    Pena, Roselyn C.
    Bertotti, Mauro
    Brett, Christopher M. A.
    ELECTROANALYSIS, 2011, 23 (10) : 2290 - 2296
  • [47] Amperometric determination of nitric oxide at a carbon nanotube modified electrode with redox polymer coating
    Junjie Fei
    Shengshui Hu
    Kwok-Keung Shiu
    Journal of Solid State Electrochemistry, 2011, 15 : 519 - 523
  • [48] Amperometric determination of nitric oxide at a carbon nanotube modified electrode with redox polymer coating
    Fei, Junjie
    Hu, Shengshui
    Shiu, Kwok-Keung
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2011, 15 (03) : 519 - 523
  • [49] A Prussian Blue Modified Electrode Based Amperometric Sensor for Lactate Determination
    Kuntawong, Parnpim
    Lertanantawong, Benchaporn
    Promptmas, Chamras
    2022 14TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2022), 2022,
  • [50] AMPEROMETRIC DETERMINATION OF NITRITE BY OXIDATION AT A GLASSY-CARBON ELECTRODE
    NEWBERY, JE
    DEHADDAD, MPL
    ANALYST, 1985, 110 (01) : 81 - 82