Clavicle anatomy and the applicability of intramedullary midshaft fracture fixation

被引:14
|
作者
Bachoura, Abdo
Deane, Andrew S. [2 ]
Kamineni, Srinath [1 ]
机构
[1] Univ Kentucky, Elbow Shoulder Res Ctr, Dept Orthopaed Surg & Sports Med, Kentucky Clin K412, Lexington, KY 40536 USA
[2] Univ Kentucky, Dept Anat & Neurobiol, Lexington, KY 40536 USA
关键词
Clavicle; anatomy; midshaft fracture; intramedullary fixation; PIN FIXATION; COMPLICATIONS; NONUNION;
D O I
10.1016/j.jse.2011.10.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study investigated the morphologic safety and applicability of intramedullary fixation of midshaft clavicle fractures by analyzing the pertinent clavicle anatomy using 3-dimensional computer simulation. Materials and methods: Computed tomography was used to scan 22 skeletonized clavicles. Computer software was used to simulate middle-segment fracture fixation by fitting a cylindrical corridor within the clavicle in the area that intramedullary devices normally cross during surgery. The cylindrical corridor crossed the fracture line on both sides, and the number of cortical diameters that were bypassed was recorded. We assumed that 1 to 2 cortical diameters had to be bypassed to achieve adequate fixation. The medial and lateral exit points of the cylindrical corridor were measured and described in relation to the sternoclavicular and acromioclavicular ends respectively. Results: Simulation revealed that 15 of 22 clavicles could be bypassed by 2 cortical diameters on either side of the midline fracture, 6 clavicles could be bypassed by 1 cortical diameter medial to the fracture line, and 1 clavicle could not be bypassed by any cortical diameters medial to the fracture line. The medial exit point of the cylindrical corridor was anterior in 20 of 22 cases and an average of 44.2 mm lateral to the sternoclavicular end. The lateral exit point of the cylindrical corridor was posterosuperior in 16 of 22 cases and an average of 26.5 mm medial to the acromioclavicular end. Conclusion: In most clavicles, straight intramedullary fixation appears to be a morphologically safe and effective method of fixation.
引用
收藏
页码:1384 / 1390
页数:7
相关论文
共 50 条
  • [31] Surgical fixation of displaced midshaft clavicle fractures: elastic intramedullary nailing versus precontoured plating
    Narsaria N.
    Singh A.K.
    Arun G.R.
    Seth R.R.S.
    Journal of Orthopaedics and Traumatology, 2014, 15 (3) : 165 - 171
  • [32] Biomechanical analysis of intramedullary vs. superior plate fixation of transverse midshaft clavicle fractures
    Wilson, David J.
    Scully, William F.
    Min, Kyong S.
    Harmon, Tess A.
    Eichinger, Josef K.
    Arrington, Edward D.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (06) : 949 - 953
  • [33] Fracture patterns in midshaft clavicle fractures
    Van Tongel, Alexander
    de Wilde, Lieven
    Shimamura, Yasunori
    Sijbers, Jan
    Huysmans, Toon
    ACTA ORTHOPAEDICA BELGICA, 2021, 87 (03): : 501 - 507
  • [34] Adolescent Displaced Midshaft Clavicle Fracture
    Assafiri, Ibrahim
    Sraj, Shafic
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (01): : 145 - 147
  • [35] Intramedullary fixation versus plate fixation in the treatment of midshaft clavicle fractures: a meta-analysis of randomized controlled trials
    Lu, Minpeng
    Qiu, Hao
    Liu, Yuting
    Dong, Jing
    Jiang, Lingfang
    FRONTIERS IN SURGERY, 2024, 10
  • [36] FUNCTIONAL OUTCOME OF CONTOURED ANATOMICAL PLATE FIXATION FOR ACUTE DISPLACED MIDSHAFT FRACTURE CLAVICLE
    Kyavater, Basavaraj S.
    Gupta, Siddhartha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (52): : 9082 - 9087
  • [37] Reducing unnecessary fixation of midshaft clavicle fractures
    Nicholas J. Murray
    Tobias Johnson
    Iain N. Packham
    Mark A. A. Crowther
    Tim J. S. Chesser
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 1319 - 1324
  • [38] Reducing unnecessary fixation of midshaft clavicle fractures
    Murray, Nicholas J.
    Johnson, Tobias
    Packham, Iain N.
    Crowther, Mark A. A.
    Chesser, Tim J. S.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (07): : 1319 - 1324
  • [39] Biomechanical comparison of three different plate configurations for comminuted clavicle midshaft fracture fixation
    Uzer, Gokcer
    Yildiz, Fatih
    Batar, Suat
    Bozdag, Ergun
    Kuduz, Hacer
    Bilsel, Kerem
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (12) : 2200 - 2205