Clavicle anatomy and the applicability of intramedullary midshaft fracture fixation

被引:14
|
作者
Bachoura, Abdo
Deane, Andrew S. [2 ]
Kamineni, Srinath [1 ]
机构
[1] Univ Kentucky, Elbow Shoulder Res Ctr, Dept Orthopaed Surg & Sports Med, Kentucky Clin K412, Lexington, KY 40536 USA
[2] Univ Kentucky, Dept Anat & Neurobiol, Lexington, KY 40536 USA
关键词
Clavicle; anatomy; midshaft fracture; intramedullary fixation; PIN FIXATION; COMPLICATIONS; NONUNION;
D O I
10.1016/j.jse.2011.10.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study investigated the morphologic safety and applicability of intramedullary fixation of midshaft clavicle fractures by analyzing the pertinent clavicle anatomy using 3-dimensional computer simulation. Materials and methods: Computed tomography was used to scan 22 skeletonized clavicles. Computer software was used to simulate middle-segment fracture fixation by fitting a cylindrical corridor within the clavicle in the area that intramedullary devices normally cross during surgery. The cylindrical corridor crossed the fracture line on both sides, and the number of cortical diameters that were bypassed was recorded. We assumed that 1 to 2 cortical diameters had to be bypassed to achieve adequate fixation. The medial and lateral exit points of the cylindrical corridor were measured and described in relation to the sternoclavicular and acromioclavicular ends respectively. Results: Simulation revealed that 15 of 22 clavicles could be bypassed by 2 cortical diameters on either side of the midline fracture, 6 clavicles could be bypassed by 1 cortical diameter medial to the fracture line, and 1 clavicle could not be bypassed by any cortical diameters medial to the fracture line. The medial exit point of the cylindrical corridor was anterior in 20 of 22 cases and an average of 44.2 mm lateral to the sternoclavicular end. The lateral exit point of the cylindrical corridor was posterosuperior in 16 of 22 cases and an average of 26.5 mm medial to the acromioclavicular end. Conclusion: In most clavicles, straight intramedullary fixation appears to be a morphologically safe and effective method of fixation.
引用
收藏
页码:1384 / 1390
页数:7
相关论文
共 50 条
  • [1] Intramedullary Fixation of Midshaft Clavicle Fractures
    Fritz, Erik M.
    van der Meijden, Olivier A.
    Hussain, Zaamin B.
    Pogorzelski, Jonas
    Millett, Peter J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 : S42 - S44
  • [2] Intramedullary screw fixation for midshaft fractures of the clavicle
    Khalil, Ayman
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (05) : 1421 - 1424
  • [3] Intramedullary screw fixation for midshaft fractures of the clavicle
    Ayman Khalil
    International Orthopaedics, 2009, 33 : 1421 - 1424
  • [4] Intramedullary Screw Fixation for Midshaft Clavicle Fractures
    Bents, Robert Thurston
    Bents, Easton James
    ARTHROSCOPY TECHNIQUES, 2024, 13 (03):
  • [5] Operative Fixation of a Displaced Midshaft Clavicle Fracture
    Campbell, David H.
    McKee, Michael D.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 : S3 - S4
  • [6] Predicting suitability of intramedullary fixation for displaced midshaft clavicle fractures
    M. H. J. Hulsmans
    M. van Heijl
    H. Frima
    O. A. J. van der Meijden
    H. R. van den Berg
    A. H. van der Veen
    A. C. Gunning
    R. M. Houwert
    E. J. M. M. Verleisdonk
    European Journal of Trauma and Emergency Surgery, 2018, 44 : 581 - 587
  • [7] Intramedullary Screw Fixation of Midshaft Clavicle Fractures: A Surgical Technique
    Balog, Todd P.
    Wilson, David J.
    Min, Kyong S.
    Grassbaugh, Jason A.
    Arrington, Edward D.
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2014, 15 (03): : 98 - 102
  • [8] Predicting suitability of intramedullary fixation for displaced midshaft clavicle fractures
    Hulsmans, M. H. J.
    van Heijl, M.
    Frima, H.
    van der Meijden, O. A. J.
    van den Berg, H. R.
    van der Veen, A. H.
    Gunning, A. C.
    Houwert, R. M.
    Verleisdonk, E. J. M. M.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2018, 44 (04) : 581 - 587
  • [9] Complications of intramedullary Hagie pin fixation for acute midshaft clavicle fractures
    Strauss, Eric J.
    Egol, Kenneth A.
    France, Monet A.
    Koval, Kenneth J.
    Zuckerman, Joseph D.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (03) : 280 - 284
  • [10] A biomechanical study of plate versus intramedullary devices for midshaft clavicle fixation
    Golish S.R.
    Oliviero J.A.
    Francke E.I.
    Miller M.D.