Entropy indices vs the bispectral index™ for estimating nociception during sevoflurane anaesthesia

被引:69
|
作者
Takamatsu, I
Ozaki, M
Kazama, T
机构
[1] Natl Def Med Coll, Dept Anaesthesiol, Tokorozawa, Saitama 3598513, Japan
[2] Tokyo Womens Med Univ, Dept Anaesthesiol, Tokyo, Japan
关键词
anaesthetics volatile; sevoflurane; measurement techniques; spectral analysis; monitoring; bispectral index; potency; analgesic;
D O I
10.1093/bja/ael050
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. It is now possible to acquire and process raw EEG and frontal EMG signals to produce two spectral-entropy-based indices (response entropy and state entropy) reflective of analgesic and hypnotic levels during general anaesthesia (with the Datex-Ohmeda S/5 Entropy Module, Datex-Ohmeda, Helsinki, Finland). However, there are no data available on the accuracy of the Entropy Module in estimating nociception during sevoflurane anaesthesia. Methods. Forty female patients were enrolled in the present study. Each patient was allocated randomly to one of four end-tidal sevoflurane concentration (ETsev) groups (1.3, 1.7, 2.1 or 2.5%). A BIS Sensor (TM) (Aspect Medical Systems, Newton, MA) and an Entropy Sensor (TM) (Datex-Ohmeda) were applied side-by-side to the forehead. The bispectral index (A-2000 BIS Monitor, version 3.4, Aspect Medical Systems), response entropy, state entropy and patient movement were observed after electrical stimulation (20, 40, 60 and 80 mA, 100 Hz, 5 s) and after skin incision during sevoflurane anaesthesia (1.3, 1.7, 2.1 or 2.5%). Accuracy of the EEG variables in differentiating the intensity of electrical stimulation was estimated by the prediction probability (P-K) values. Results. Response entropy and state entropy [median, (range)] before skin incision were significantly lower in patients who did not move [29 (15-41) and 24 (14-41)] than in those that did [38 (24-53) and 37 (24-52)], but there was no significant difference in BIS. All EEG variables increased significantly (P < 0.0001 for all) with increases in the intensity of electrical stimulation. The difference between response entropy and state entropy increased with increases in the electrical stimulation (P < 0.0001). However, no EEG variables could differentiate the intensity of the electrical stimulations accurately because of low P-K-values (P-K < 0.8). Conclusion. Noxious stimulation increased the difference between response entropy and state entropy. However, an increase in the difference does not always indicate inadequate analgesia and should be interpreted carefully during anaesthesia.
引用
收藏
页码:620 / 626
页数:7
相关论文
共 50 条
  • [11] Comparative effects of ketamine on Bispectral Index and spectral entropy of the electroencephalogram under sevoflurane anaesthesia
    Hans, P
    Dewandre, PY
    Brichant, JF
    Bonhomme, V
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (03) : 336 - 340
  • [12] Bispectral index and state entropy of the electroencephalogram during propofol anaesthesia
    Bonhomme, V. L.
    Hans, P. C.
    BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (01) : 145 - 146
  • [13] Bispectral index monitoring during balanced xenon or sevoflurane anaesthesia in elderly patients
    Fahlenkamp, Astrid V.
    Krebber, Franziska
    Rex, Steffen
    Grottke, Oliver
    Fries, Michael
    Rossaint, Rolf
    Coburn, Mark
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (10) : 906 - 911
  • [14] Validation of the index of consciousness during sevoflurane and remifentanil anaesthesia: a comparison with the bispectral index and the cerebral state index
    Revuelta, M.
    Paniagua, P.
    Campos, J. M.
    Fernandez, J. A.
    Martinez, A.
    Jospin, M.
    Litvan, H.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (05) : 653 - 658
  • [15] Relationship of bispectral index to minimum alveolar concentration during isoflurane, sevoflurane or desflurane anaesthesia
    Kim, Jin-Kyoung
    Kim, Duk-Kyung
    Lee, Myeong-Jin
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2014, 42 (01) : 130 - 137
  • [16] Effect of age on the comparability of bispectral and state entropy indices during the maintenance of propofolsufentanil anaesthesia
    Aime, I.
    Gayat, E.
    Fermanian, C.
    Cook, F.
    Peuch, C.
    Laloe, P. A.
    Mantz, J.
    Fischler, M.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (04) : 638 - 643
  • [17] Effect of age on the performance of bispectral and entropy indices during sevoflurane pediatric anesthesia: a pharmacometric study
    Sciusco, Alberto
    Standing, Joseph F.
    Sheng, Yucheng
    Raimondo, Pasquale
    Cinnella, Gilda
    Dambrosio, Michele
    PEDIATRIC ANESTHESIA, 2017, 27 (04) : 399 - 408
  • [18] Spectral entropy and bispectral index as measures of the electroencephalographic effects of sevoflurane
    Ellerkmann, RK
    Liermann, VM
    Alves, TM
    Wenningmann, I
    Kreuer, S
    Wilhelm, W
    Roepcke, H
    Hoeft, A
    Bruhn, J
    ANESTHESIOLOGY, 2004, 101 (06) : 1275 - 1282
  • [19] Spectral Entropy and bispectral index as measures of the EEG effects of sevoflurane
    Ellerkmann, R. K.
    Liermann, M.
    Alves, T.
    Roepke, H.
    Wenningmann, I.
    Hoeft, A.
    Bruhn, J.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 34 - 34
  • [20] Doxapram and aminophylline on bispectral index under sevoflurane anaesthesia: a comparative study
    Wu, C. -C.
    Lin, C. -S.
    Wu, G. -J.
    Lin, Y-H.
    Lee, Y-W.
    Chen, J. -Y
    Mok, M. S.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (11) : 937 - 941