Investigations of self-absorption in a radio-frequency glow discharge device

被引:8
|
作者
Winchester, MR [1 ]
Marcus, RK [1 ]
机构
[1] CLEMSON UNIV,HOWARD L HUNTER CHEM LAB,DEPT CHEM,CLEMSON,SC 29634
基金
美国国家科学基金会;
关键词
Fourier transform spectrometry; radio-frequency glow discharge; self-absorption;
D O I
10.1016/0584-8547(96)01473-5
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The self-absorption behavior of a radio-frequency glow discharge atomic emission device has been studied with Fourier transform spectrometry. Using a resonant transition of a major element, it has been shown that for this device the potential for self-absorption is severe, and no analytically useful discharge conditions that significantly reduce that potential were found. In fact, it is unlikely that such conditions can be found, even with a more exhaustive study. Therefore, there is no compelling reason to alter the discharge conditions that would typically be employed for analyses with the device. Based on the potential for self-absorption, it is advisable to use non-resonant, rather than resonant, transitions of major elements for analytical purposes. On the other hand, the use of resonant transitions of minor or trace elements appears to be free from any significant danger of analytical error induced by self-absorption. However, further studies are needed to validate this conclusion over a wider range of analytes, transitions, sample types, and discharge conditions. Owing to the fact that self-absorption is influenced by the subtleties of the design of a glow discharge device, such as the placement of a vacuum port, these results should not be assumed to be wholly applicable to other glow discharge devices.
引用
收藏
页码:839 / 850
页数:12
相关论文
共 50 条
  • [31] Modes in a pulse-modulated radio-frequency dielectric-barrier glow discharge
    Shi, J. J.
    Zhang, J.
    Qiu, G.
    Walsh, J. L.
    Kong, M. G.
    APPLIED PHYSICS LETTERS, 2008, 93 (04)
  • [32] The effect of radio-frequency glow discharge treatment of polystyrene on the behavior of porcine chondrocytes in vitro
    Tsai, WB
    Wei, TC
    Lin, MC
    Wang, JP
    Chen, CH
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2005, 16 (06) : 699 - 714
  • [33] SPACE-TIME RESOLVED DIAGNOSTICS OF RADIO-FREQUENCY GLOW-DISCHARGE KINETICS
    GOTTSCHO, RA
    JOURNAL DE PHYSIQUE, 1987, 48 (C-7): : 693 - 699
  • [34] Description of the argon-excited levels in a radio-frequency and direct current glow discharge
    Bogaerts, A
    Gijbels, R
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (03) : 263 - 278
  • [35] SILANE REFUNCTIONALIZATION OF RADIO-FREQUENCY GLOW-DISCHARGE HYDROLYZED EPTFE MEMBRANE SURFACES
    VARGO, TG
    HOOK, DJ
    LITWILER, KS
    BRIGHT, FV
    GARDELLA, JA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 53 - PMSE
  • [36] ACTIVITY OF HORSERADISH PEROXIDE ADSORBED ON RADIO-FREQUENCY GLOW DISCHARGE-TREATED POLYMERS
    CHEN, JP
    KIAEI, D
    HOFFMAN, AS
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1993, 5 (1-2) : 167 - 182
  • [37] Effects of Helium Addition to Radio-Frequency Argon Glow-Discharge Mass Spectrometry
    KRISS, P. O. Box 102, Yusong, Taejon 305-606, Korea, Republic of
    不详
    Anal. Sci., 3 (459-464):
  • [38] Modeling of two-dimensional radio-frequency methane glow discharge in cylindrical geometry
    Bera, K
    Farouk, B
    Lee, Y
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1998, 41 (02) : 429 - 435
  • [39] Effects of helium addition to radio-frequency argon glow-discharge mass spectrometry
    Woo, JC
    Moon, DM
    Tanaka, T
    Matsuno, M
    Kawaguchi, H
    ANALYTICAL SCIENCES, 1996, 12 (03) : 459 - 464
  • [40] Numerical study on characteristics of argon radio-frequency glow discharge with varying gas pressure
    Yu Qian
    Deng Yong-Feng
    Liu Yue
    Han Xian-Wei
    CHINESE PHYSICS LETTERS, 2008, 25 (07) : 2569 - 2572