Biomimetic Sensor Potentiometric System for Doxycycline Antibiotic Using a Molecularly Imprinted Polymer as an Artificial Recognition Element

被引:15
|
作者
Kamel, Ayman H. [1 ]
Moreira, Felismina T. C. [1 ]
Sales, M. Goreti F. [1 ]
机构
[1] REQUIMTE, Inst Super Engn Porto, P-4200072 Oporto, Portugal
关键词
Potentiometry; Doxycycline; Molecular Imprinting Polymers; Binding Capacity; Flow Injection Analysis (FIA); PERFORMANCE LIQUID-CHROMATOGRAPHY; TETRACYCLINE ANTIBIOTICS; PHARMACEUTICAL FORMULATIONS; CHLORTETRACYCLINE; OXYTETRACYCLINE; MUSCLE; VALIDATION; RESIDUES; MILK;
D O I
10.1166/sl.2011.1707
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Molecular imprinting is a useful technique for the preparation of functional materials with molecular recognition properties. A Biomimetic Sensor Potentiometric System was developed for assessment of doxycycline (DOX) antibiotic. The molecularly imprinted polymer (MIP) was synthesized by using doxycycline as a template molecule, methacrylic acid (MAA) and/or acrylamide (AA) as a functional monomer and ethylene glycol dimethacrylat (EGDMA) as a cross-linking agent. The sensing elements were fabricated by the inclusion of DOX imprinted polymers in polyvinyl chloride (PVC) matrix. The sensors showed a high selectivity and a sensitive response to the template in aqueous system. Electrochemical evaluation of these sensors under static (batch) mode of operation reveals near-Nernstian response. MIP/MAA membrane sensor was incorporated in flow-through cells and used as detectors for flow injection analysis (FIA) of DOX. The method has the requisite accuracy, sensitivity and precision to assay DOX in tablets and biological fluids.
引用
收藏
页码:1654 / 1660
页数:7
相关论文
共 50 条
  • [21] Electrochemical Sensor for Dapsone Using Molecularly Imprinted Polypyrrole Membrane as a Recognition Element
    Afkhami, Abbas
    Gomar, Fatemeh
    Madrakian, Tayyebeh
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (06) : B109 - B113
  • [22] A Molecularly Imprinted Polymer (MIP)-based Biomimetic Potentiometric sensing device for the analysis of Clarithromycin
    Mahmoudi, Shirin
    Rashedi, Hamid
    Faridbod, Farnoush
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (12): : 1654 - 1667
  • [23] Man-tailored biomimetic sensor of molecularly imprinted materials for the potentiometric measurement of oxytetracycline
    Moreira, Felismina T. C.
    Kamel, Ayman H.
    Guerreiro, Joana R. L.
    Sales, M. Goreti F.
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (02): : 566 - 574
  • [24] Biomimetic piezoelectric quartz sensor for caffeine based on a molecularly imprinted polymer
    Benilda S. Ebarvia
    Christina A. Binag
    Fortunato Sevilla III
    Analytical and Bioanalytical Chemistry, 2004, 378 : 1331 - 1337
  • [25] Biomimetic piezoelectric quartz sensor for caffeine based on a molecularly imprinted polymer
    Ebarvia, BS
    Binag, CA
    Sevilla, F
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (05) : 1331 - 1337
  • [26] Intrinsic Fluorescence-Based Optical Fiber Sensor for Cocaine Using a Molecularly Imprinted Polymer as the Recognition Element
    Nguyen, T. Hien
    Hardwick, Sheila A.
    Sun, Tong
    Grattan, Kenneth T. V.
    IEEE SENSORS JOURNAL, 2012, 12 (01) : 255 - 260
  • [27] Selective Recognition of Herbicides in Water Using a Fluorescent Molecularly Imprinted Polymer Sensor
    Limaee, Nargess Yousefi
    Rouhani, Shohre
    Olya, Mohammad Ebrahim
    Najafi, Farhood
    JOURNAL OF FLUORESCENCE, 2020, 30 (02) : 375 - 387
  • [28] Selective Recognition of Herbicides in Water Using a Fluorescent Molecularly Imprinted Polymer Sensor
    Nargess Yousefi Limaee
    Shohre Rouhani
    Mohammad Ebrahim Olya
    Farhood Najafi
    Journal of Fluorescence, 2020, 30 : 375 - 387
  • [29] Voltammetric Determination of Pindolol in Biological Fluids Using Molecularly Imprinted Polymer Based Biomimetic Sensor
    Tadi, Kiran Kumar
    Motghare, Ramani V.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (07) : B286 - B292
  • [30] Designing of molecularly imprinted polymer-based potentiometric sensor for the determination of heparin
    Li, Lifeng
    Liang, Yizeng
    Liu, Youcai
    ANALYTICAL BIOCHEMISTRY, 2013, 434 (02) : 242 - 246