Candida Endophthalmitis After Descemet Stripping Automated Endothelial Keratoplasty With Grafts From Both Eyes of a Donor With Possible Systemic Candidiasis

被引:22
|
作者
Palioura, Sotiria [1 ]
Sivaraman, Kavitha [1 ]
Joag, Madhura [1 ]
Sise, Adam [1 ]
Batlle, Juan F., Jr. [1 ]
Miller, Darlene [1 ]
Espana, Edgar M. [2 ]
Amescua, Guillermo [1 ]
Yoo, Sonia H. [1 ]
Galor, Anat [1 ,2 ]
Karp, Carol L. [1 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Dept Ophthalmol, Miami, FL 33136 USA
[2] Univ S Florida, Morsani Coll Med, Inst Eye, Dept Ophthalmol, Tampa, FL USA
关键词
DSAEK; Candida albicans; fungal interface keratitis; eye bank; intrastromal voriconazole injection; KERATITIS; INFECTION;
D O I
10.1097/ICO.0000000000001333
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To report 2 cases with late postoperative Candida albicans interface keratitis and endophthalmitis after Descemet stripping automated endothelial keratoplasty (DSAEK) with corneal grafts originating from a single donor with a history of presumed pulmonary candidiasis.Methods:Two patients underwent uncomplicated DSAEK by 2 corneal surgeons at different surgery centers but with tissue from the same donor and were referred to the Bascom Palmer Eye Institute with multifocal infiltrates at the graft-host cornea interface 6 to 8 weeks later, and anterior chamber cultures that were positive for the same genetic strain of C. albicans. Immediate explantation of DSAEK lenticules and daily intracameral and instrastromal voriconazole and amphotericin injections failed to control the infection. Thus, both patients underwent therapeutic penetrating keratoplasty with intraocular lens explantation, pars plana vitrectomy, and serial postoperative intraocular antifungal injection.Results:Both patients are doing well at 2 years postoperatively with best-corrected vision of 20/20 and 20/30+ with rigid gas permeable lenses. One patient required repeat optical penetrating keratoplasty and glaucoma tube implantation 1 year after the original surgery. Literature review reveals that donor lenticule explantation and intraocular antifungals are often inadequate to control fungal interface keratitis, and a therapeutic graft is commonly needed.Conclusions:Interface fungal keratitis and endophthalmitis due to infected donor corneal tissue is difficult to treat, and both recipients of grafts originating from the same donor are at risk of developing this challenging condition.
引用
收藏
页码:515 / 518
页数:4
相关论文
共 50 条
  • [21] Survey of complications in Descemet stripping automated endothelial keratoplasty in 32 eyes
    Ponchel, C.
    Arne, J. L.
    Malecaze, F.
    Fournie, P.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2009, 32 (07): : 464 - 473
  • [22] Descemet Stripping Automated Endothelial Keratoplasty After Failed Penetrating Keratoplasty
    Jangi, Anisha A.
    Ritterband, David C.
    Wu, Elaine I.
    Mehta, Veeral V.
    Koplin, Richard S.
    Seedor, John A.
    CORNEA, 2012, 31 (10) : 1148 - 1153
  • [23] Descemet's stripping and non-Descemet's stripping automated endothelial keratoplasty for microcornea using 6.0 mm donor grafts
    Yokogawa, Hideaki
    Kobayashi, Akira
    Yamazaki, Natsuko
    Ueta, Yoshiki
    Hashimoto, Yoshihiro
    Tachi, Naoko
    Sugiyama, Kazuhisa
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 1951 - 1956
  • [24] Endothelial cell counts after Descemet's stripping automated endothelial keratoplasty versus penetrating keratoplasty in Asian eyes
    Ang, Marcus
    Mehta, Jodhbir S.
    Anshu, Arundhati
    Wong, Hon Kiat
    Htoon, Hla M.
    Tan, Donald
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 537 - 544
  • [25] Descemet Membrane Endothelial Keratoplasty as Treatment for Graft Failure After Descemet Stripping Automated Endothelial Keratoplasty
    Weller, Julia M.
    Tourtas, Theofilos
    Kruse, Friedrich E.
    Schloetzer-Schrehardt, Ursula
    Fuchsluger, Thomas
    Bachmann, Bjoern O.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (06) : 1050 - 1057
  • [26] The First 100 Eyes of Standardized Descemet Stripping Automated Endothelial Keratoplasty versus Standardized Descemet Membrane Endothelial Keratoplasty
    Hamzaoglu, Ebru C.
    Straiko, Michael D.
    Mayko, Zachary M.
    Sales, Christopher S.
    Terry, Mark A.
    OPHTHALMOLOGY, 2015, 122 (11) : 2193 - 2199
  • [27] Early-onset severe donor-related Candida keratitis after Descemet stripping automated endothelial keratoplasty
    Hsu, Ya-Jui
    Huang, Jen-Shang
    Tsai, Jia-Huei
    Hu, Fung-Rong
    Hou, Yu-Chih
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2014, 113 (11) : 874 - 876
  • [28] Outcome of Descemet membrane endothelial keratoplasty for graft failure after Descemet stripping automated endothelial keratoplasty
    Agha, Bishr
    Shajari, Mehdi
    Slavik-Lencova, Anna
    Kohnen, Thomas
    Schmack, Ingo
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 553 - 559
  • [29] Comparison of donor insertion techniques for Descemet stripping automated endothelial keratoplasty
    Mehta, Jodhbir S.
    Por, Yong Ming
    Poh, Rebekah
    Beuerman, Roger W.
    Tan, Donald
    ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (10) : 1383 - 1388
  • [30] Descemet-stripping automated endothelial keratoplasty with a donor tissue injector
    Khor, Wei-Boon
    Kim, Terry
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (11): : 1768 - 1772