Capillary electrophoresis and contactless conductivity detection of ions in narrow inner diameter capillaries

被引:102
|
作者
Mayrhofer, K [1 ]
Zemann, AJ [1 ]
Schnell, E [1 ]
Bonn, GK [1 ]
机构
[1] Univ Innsbruck, Inst Analyt Chem & Radiochem, A-6020 Innsbruck, Austria
关键词
D O I
10.1021/ac990019o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary electrophoresis and conductometry represent a combination of a high-resolution separation method with a sensitive detection principle for the analysis of ionic species. In this paper, results are reported that are obtained with a contactless conductivity detector. This device works without a galvanic contact of the electrolyte and the electrodes. The conductivity sensor is based on two metal tubes that act as cylindrical capacitors. These electrodes are both placed around a fused-silica capillary with a detection gap of 1 mm left in between. When a high audio or low ultrasonic oscillation frequency between 40 and 100 kHz is applied to one of the electrodes, a signal is produced as soon as an analyte zone with a different conductivity compared to the background electrolyte passes the detection gap. An amplifier and rectifier is connected to the other electrode where the signal is further processed. Limits of detection for lithium and fluoride are 4 and 13 ppb, respectively, with a linear range over 4 orders of magnitude from 90 ppb up to more than 1000 ppm for both anions and cations. Furthermore, it is demonstrated that for species with lower equivalent conductivities, such as organic ions, indirect conductivity detection is a sensitive alternative to indirect optical detection methods. Limits of detection of 50 ppb and below are obtained for organic acids.
引用
收藏
页码:3828 / 3833
页数:6
相关论文
共 50 条
  • [2] Contactless Conductivity Detection in Capillary Electrophoresis in Combination with Capillaries with Thin Inner Diameter
    Tuma, Petr
    Samcova, Eva
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 168 - 172
  • [3] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Schnell, E
    Volgger, D
    Bonn, GK
    ANALYTICAL CHEMISTRY, 1998, 70 (03) : 563 - 567
  • [4] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Mayrhofer, K
    Schnell, E
    Bonn, GK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U162 - U162
  • [5] Contactless conductivity detection in capillary zone electrophoresis
    Kaniansky, D
    Zelenská, V
    Masár, M
    Iványi, F
    Gazdíková, S
    JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) : 349 - 359
  • [6] Contactless conductivity detection in capillary electrophoresis:: A review
    Kubán, P
    Hauser, PC
    ELECTROANALYSIS, 2004, 16 (24) : 2009 - 2021
  • [7] Considerations on contactless conductivity detection in capillary electrophoresis
    Baltussen, E
    Guijt, RM
    van der Steen, G
    Laugere, F
    Baltussen, S
    van Dedem, GWK
    ELECTROPHORESIS, 2002, 23 (17) : 2888 - 2893
  • [8] High-voltage contactless conductivity detection of metal ions in capillary electrophoresis
    Tanyanyiwa, J
    Hauser, PC
    ELECTROPHORESIS, 2002, 23 (21) : 3781 - 3786
  • [9] Electrophoresis in nanometer inner diameter capillaries with electrochemical detection
    Woods, LA
    Roddy, TP
    Paxon, TL
    Ewing, AG
    ANALYTICAL CHEMISTRY, 2001, 73 (15) : 3687 - 3690
  • [10] Capacitively Coupled Contactless Conductivity Detection in Capillary Electrophoresis
    Tan Feng
    Guan Yafeng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (02) : 152 - 157