Optimal shape of LCVA for vibration control of structures subjected to along wind excitation

被引:2
|
作者
Park, Ji-Hun [2 ]
Min, Kyung-Won [1 ]
机构
[1] Dankook Univ, Dept Architectural Engn, Yongin, South Korea
[2] Univ Incheon, Dept Architectural Engn, Inchon, South Korea
关键词
liquid column vibration absorber; vibration control; equivalent damping ratio; LIQUID COLUMN DAMPERS; RESPONSE CONTROL; TALL BUILDINGS; ABSORBERS LCVA; OPTIMIZATION; PERFORMANCE;
D O I
10.12989/sss.2012.10.6.573
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, a procedure to design an optimal LCVA that maximizes the equivalent damping ratio added to the primary structure subjected to along-wind excitation is proposed. That design procedure does not only consider the natural frequency and damping ratio of the LCVA, but also the proportion of the U-shaped liquid, which is closely related to the participation ratio of the liquid mass in inertial force. In addition, constraints to ensure the U-shape of the liquid are considered in the design process, so that suboptimal solutions that violate the optimal tuning law partly are adopted as a candidate of the optimal LCVA. The proposed design procedure of the LCVA is applied to the control of the 76-story benchmark building, and the optimal proportions of the liquid shape under various design conditions are compared.
引用
收藏
页码:573 / 591
页数:19
相关论文