Objectives-The aim of this clinical study was to evaluate the reproducibility of quantitative assessment of altered hepatic hemodynamics with dynamic contrast-enhanced ultrasound. Methods-Fifteen patients with colorectal liver metastases and 5 volunteers were studied. The hepatic artery proper and the portal vein were imaged simultaneously with dynamic contrast-enhanced ultrasound. The examination was repeated with 2 different contrast bolus volumes (1.2 and 2.4 mL), and time-intensity curves were formed from dynamic contrast-enhanced ultrasound image loops. The rise time, peak intensity, and wash-in slope were derived from hepatic artery and portal vein time-intensity curves. Inter-reader, intra-reader, and inter-scan agreement was assessed by 2 independent readers. Quantitative (intraclass correlation coefficients and coefficients of variation [CVs]) and qualitative (Landis and Koch classification) analyses were performed. Results-Intra-reader and inter-reader agreement was "almost perfect" for the hepatic artery (CV, 10%-15% and 8%-9%, respectively), portal vein (CV, 5%-8% and 6%-12%), and hepatic artery/portal vein ratio (CV, 8%-14% and 10%-15%) measurements of 3 all studied parameters. In contrast, inter-scan agreement was only "slight" to "moderate" (CV, 25%-27%) and "fair" to "moderate" (CV, 19%-24%) for rise time and peak intensity measurements in the hepatic artery and portal vein, respectively. Conclusions-Quantitative assessment of altered hepatic hemodynamics with dynamic contrast-enhanced ultrasound is reproducible provided that measurements in the hepatic artery are normalized by those in the portal vein.
引用
收藏
页码:1413 / 1420
页数:8
相关论文
共 50 条
  • [41] Contrast-Enhanced Ultrasound
    Xu, Hui-Xiong
    Weskott, Hans Peter
    Liu, Ji-Bin
    Zheng, Rong-Qin
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [42] Contrast-enhanced ultrasound
    Jaspers, N.
    Pfister, R.
    Kinkel, H.
    Michels, G.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2012, 137 (45) : 2336 - 2339
  • [43] Dynamic contrast-enhanced endoscopic ultrasound: A quantification method
    Dietrich, Christoph F.
    Dong, Yi
    Froehlich, Eckhart
    Hocke, Michael
    ENDOSCOPIC ULTRASOUND, 2017, 6 (01) : 12 - 20
  • [44] Blind Deconvolution in Dynamic Contrast-Enhanced MRI and Ultrasound
    Jirik, Radovan
    Soucek, Karel
    Mezl, Martin
    Bartos, Michal
    Drazanova, Eva
    Drafi, Frantisek
    Grossova, Lucie
    Kratochvila, Jiri
    Macicek, Ondrej
    Nylund, Kim
    Hampl, Ales
    Gilja, Odd Helge
    Taxt, Torfinn
    Starcuk, Zenon, Jr.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 4276 - 4279
  • [45] Dynamic Contrast-Enhanced Ultrasound for Quantification of Tissue Perfusion
    Froehlich, Eckhart
    Muller, Reinhold
    Cui, Xin-Wu
    Schreiber-Dietrich, Dagmar
    Dietrich, Christoph F.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (02) : 179 - 196
  • [46] Study of Intrapatient Variability and Reproducibility of Quantitative Tumor Perfusion Parameters Evaluated With Dynamic Contrast-Enhanced Ultrasonography
    Lassau, Nathalie
    Coiffier, Benedicte
    Faivre, Laura
    Benatsou, Baya
    Bidault, Sophie
    Girard, Elizabeth
    Asselain, Bernard
    Pitre-Champagnat, Stephanie
    Koscielny, Serge
    INVESTIGATIVE RADIOLOGY, 2017, 52 (03) : 148 - 154
  • [47] Contrast-enhanced ultrasound for blunt hepatic trauma: an animal experiment
    Li Yekuo
    Wang Shasha
    Zhu Xiansheng
    Chen Qi
    Luo Guoxin
    Huo Feng
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2010, 28 (07): : 828 - 833
  • [48] Baseline and contrast-enhanced ultrasound features of hepatic epithelioid angiomyolipoma
    Fan, Pei-Li
    Ji, Zheng-Biao
    Cao, Jia-Ying
    Xu, Chen
    Dong, Yi
    Wang, Wen-Ping
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2022, 80 (04) : 447 - 461
  • [49] Contrast-enhanced ultrasound of histologically proven hepatic epithelioid hemangioendothelioma
    Dong, Yi
    Wang, Wen-Ping
    Cantisani, Vito
    D'Onofrio, Mirko
    Ignee, Andre
    Mulazzani, Lorenzo
    Saftoiu, Adrian
    Sparchez, Zeno
    Sporea, Ioan
    Dietrich, Christoph F.
    WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (19) : 4741 - 4749
  • [50] The role of contrast-enhanced ultrasound in the diagnosis of hepatic alveolar echinococcosis
    Cai, Diming
    Li, Yongzhong
    Jiang, Yong
    Wang, Huiyao
    Wang, Xiaoling
    Song, Bin
    MEDICINE, 2019, 98 (05)