Dynamic Contrast-Enhanced Magnetic Resonance Imaging of Abdominal Solid Organ and Major Vessel: Comparison of Enhancement Effect between Gd-EOB-DTPA and Gd-DTPA

被引:103
|
作者
Tamada, Tsutomu [1 ]
Ito, Katsuyoshi [1 ]
Sone, Teruki [1 ]
Yamamoto, Akira [1 ]
Yoshida, Koji [1 ]
Kakuba, Koki [1 ]
Tanimoto, Daigo [1 ]
Higashi, Hiroki [1 ]
Yamashita, Takenori [1 ]
机构
[1] Kawasaki Med Sch, Dept Radiol, Kurashiki, Okayama 7010192, Japan
关键词
Gd-EOB-DTPA; Gd-DTPA; liver; magnetic resonance (MR); contrast enhancement; contrast media; comparative studies; GADOLINIUM-ETHOXYBENZYL-DTPA; BREATH-HOLD EXAMINATION; FOCAL LIVER-LESIONS; HEPATOCELLULAR-CARCINOMA; CLINICAL-EVALUATION; MR; AGENT; SAFETY; TUMORS;
D O I
10.1002/jmri.21689
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the differences in enhancement of the abdominal solid organ and the major vessel on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) obtained with gadolinium ethoxybenzyldiethylenetriamine pentaacetic acid (Gd-EOB-DTPA: EOB) and gadolintum diethylenetriamine pentaacetic acid (Gd-DTPA) in the same patients. Materials and Methods: A total of 13 healthy volunteers underwent repeat assessments of abdominal MR examinations with DCE-MRI using either Gd-DTPA at a dose of 0.1 mmol/kg body weight or EOB at a dose of 0.025 mmol/kg body weight. DCE images were obtained at precontrast injection and in the arterial phase (AP: 25 seconds), portal phase (PP: 70 seconds), and equilibrium phase (EP: 3 minutes). The signal intensities (SIs) of liver at AP, PP, and EP; the SIs of spleen, renal cortex, renal medulla, pancreas, adrenal gland, aorta at AP; and the SIs of portal vein and inferior vena cava (IVC) at PP were defined using region-of-interest measurements, and were used for calculation of signal intensity ratio (SIR). Results: The mean SIRs of liver (0.195 +/- 0.140), spleen (1.35 +/- 0.353), renal cortex (1.58 +/- 0.517). renal medulla (0.548 +/- 0.259). pancreas (0.540 +/- 0.183), adrenal gland (1.04 +/- 0.405), and aorta (2.44 +/- 0.648) at AP as well as the mean SIRs of portal vein (1.85 +/- 0.477) and IVC (1.16 +/- 0.187) at PP in the EOB images were significantly lower than those (0.337 +/- 0.200, 1.99 +/- 0.443, 2.01 +/- 0.474, 0.742 +/- 0.336, 0.771 +/- 0.227, 1.26 +/- 0.442, 3.22 +/- 1.20. 2.73 +/- 0.429, and 1.68 +/- 0.366, respectively) in the Gd-DTPA images (P < 0.05 each). There was no significant difference in mean SIR of liver at PP between EOB (0.529 +/- 0.124) and Gd-DTPA (0.564 +/- 0.139). Conversely, the mean SIR of liver at EP was significantly higher with EOB (0.576 +/- 0.167) than with Gd-DTPA (0.396 +/- 0.093) (P < 0.001). Conclusion: Lower arterial vascular and parenchymal enhancement with Gd-EOB, as compared with Gd-DTPA, may require reassessment of its dose, despite the higher late venous phase liver parenchymal enhancement.
引用
收藏
页码:636 / 640
页数:5
相关论文
共 50 条
  • [41] MAGNETIC-RESONANCE-IMAGING OF HUMAN CEREBRAL INFARCTION - ENHANCEMENT WITH GD-DTPA
    IMAKITA, S
    NISHIMURA, T
    NAITO, H
    YAMADA, N
    YAMAMOTO, K
    TAKAMIYA, M
    YAMADA, Y
    SAKASHITA, Y
    MINAMIKAWA, J
    KIKUCHI, H
    TERADA, T
    NEURORADIOLOGY, 1987, 29 (05) : 422 - 429
  • [42] Hepatic function imaging using dynamic Gd-EOB-DTPA enhanced MRI and pharmacokinetic modeling
    Ning, Jia
    Yang, Zhiying
    Xie, Sheng
    Sun, Yongliang
    Yuan, Chun
    Chen, Huijun
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (04) : 1488 - 1495
  • [43] Contrast-enhanced MR cholangiography with Gd-EOB-DTPA for preoperative biliary mapping: correlation with intraoperative cholangiography
    Lee, Yedaun
    Kim, So Yeon
    Kim, Kyoung Won
    Lee, Seung Soo
    Park, Seong Ho
    Byun, Jae Ho
    Lee, Moon-Gyu
    ACTA RADIOLOGICA, 2015, 56 (07) : 773 - 781
  • [44] Contrast-enhanced MR cholangiography (MRCP) with GD-EOB-DTPA in evaluating biliary complications after surgery
    Salvolini, L.
    Urbinati, C.
    Valeri, G.
    Ferrara, C.
    Giovagnoni, A.
    RADIOLOGIA MEDICA, 2012, 117 (03): : 354 - 368
  • [45] CONTRAST AGENT Gd-EOB-DTPA (EOB•Primovist®) FOR LOW-FIELD MAGNETIC RESONANCE IMAGING OF CANINE FOCAL LIVER LESIONS
    Yonetomi, Daisuke
    Kadosawa, Tsuyoshi
    Miyoshi, Kenjirou
    Nakao, Yukie
    Homma, Emi
    Hanazono, Kiwamu
    Yamada, Eriko
    Nakamura, Kozo
    Ijiri, Atsuki
    Minegishi, Noriyuki
    Maetani, Shigeki
    Hirayama, Kazuko
    Taniyama, Hiroyuki
    Nakade, Tetsuya
    VETERINARY RADIOLOGY & ULTRASOUND, 2012, 53 (04) : 371 - 380
  • [46] Hepatic Uptake of the Magnetic Resonance Imaging Contrast Agent Gd-EOB-DTPA: Role of Human Organic Anion Transporters
    Leonhardt, Mirko
    Keiser, Markus
    Oswald, Stefan
    Kuhn, Jens
    Jia, Jia
    Grube, Markus
    Kroemer, Heyo K.
    Siegmund, Werner
    Weitschies, Werner
    DRUG METABOLISM AND DISPOSITION, 2010, 38 (07) : 1024 - 1028
  • [47] Atherosclerotic plaque detection by contrast-enhanced magnetic resonance imaging. A comparative animal study of gadofluorine and Gd-DTPA
    Sirol, M
    Itskovich, VV
    Mani, V
    Aguinaldo, JG
    Weinmann, HJ
    Fuster, V
    Toussaint, JF
    Fayad, ZA
    EUROPEAN HEART JOURNAL, 2004, 25 : 146 - 146
  • [48] DYNAMIC CONTRAST-ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY OF Gd-TTDA-BOM COMPARED WITH Gd-DTPA IN NORMAL RAT AT 3T
    Jao, Jo-Chi
    Chen, Yen-Ku
    Jaw, Twei-Shiun
    Wang, Yun-Ming
    Chen, Po-Chou
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2014, 26 (02):
  • [49] Quantitative evaluation of simultaneous spatial and temporal regularization in dynamic contrast-enhanced MRI of the liver using Gd-EOB-DTPA
    Murase, Kenya
    Kashiwagi, Nobuo
    Tomiyama, Noriyuki
    MAGNETIC RESONANCE IMAGING, 2022, 88 : 25 - 37
  • [50] Improvement of vascular signal intensity in contrast-enhanced MRA with Gd-BOPTA: Comparison with Gd-DTPA
    Pavone, P
    Catalano, C
    Cademartiri, F
    Luccichenti, G
    Passariello, R
    ACADEMIC RADIOLOGY, 2002, 9 : S134 - S134