Evaluation of the Posterior Superior Alveolar Artery Prior to Sinus Floor Elevation via Lateral Window Technique: A Cone-Beam Computed Tomography Study

被引:3
|
作者
Bedeloglu, Elcin [1 ]
Yalcin, Mustafa [2 ]
机构
[1] Istanbul Aydin Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Istanbul, Turkey
[2] Gaziantep Univ, Dept Oral & Maxillofacial Surg, Fac Dent, TR-27310 Gaziantep, Turkey
关键词
Cone-beam computed tomography; Maxillary sinus lateral wall; Posterior superior alveolar artery; Sinus floor elevation; MAXILLARY SINUS; RADIOGRAPHIC EVALUATION; WALL; PREVALENCE; ANATOMY; COMPLICATIONS; DIAMETER; LOCATION;
D O I
10.1177/2320206820940463
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: To evaluate the prevalence, diameter, localization of the posterior superior alveolar artery (PSAA) and the relationship between PSAA and the floor of the maxillary sinus and the thickness of the maxillary sinus lateral wall using cone-beam computed tomography (CBCT). Material and Methods: In this retrospective study, more than 500 CBCT images were retrieved. Out of them 156 CBCT images were related to the sinus floor elevation, among which 120 CBCT images were enrolled in the study based on the inclusion criteria, and 36 CBCT images were excluded. A total of 120 CBCT images of the PSSA from 60 patients comprising 32 (53.3%) men and 28 (46.7%) women were analyzed. Statistical data were analyzed using SPSS for Windows version 22. Descriptive statistics (mean, standard deviation, frequency) were used for the analyses. Results: The ages of the participants ranged between 26 and 76 years and the mean age was 54.48 +/- 10.92 years. The PSAA was detected on the right side in 95% of the CBCT scans and on the left side in 85% of the maxillary sinuses. At the first detection point (FDP) and last detection point (LDP), the mean values of the distance between the inferior border of the PSAA and the floor of the maxillary sinus were 9.54 +/- 4.27 mm and 7.91 +/- 4.75 mm, respectively. The mean diameters of the PSAA at the FDP and LDP were 1.36 +/- 0.46 mm and 1.12 +/- 0.35 mm, respectively. Conclusion: Detection of the characteristics of the PSAA by using CBCT is crucial for handling the sinus floor elevation procedures uneventfully.
引用
收藏
页码:215 / 223
页数:9
相关论文
共 50 条
  • [41] Role of Cone-Beam Computed Tomography in Assessment of Lateral Wall Thickness of Maxillary Sinus in Posterior Edentulous Maxilla
    Giri, Debanti
    Lalrawngbawli, F.
    Giri, Tapan K.
    Biswas, Debabrata
    Banerjee, Saurav
    Banerjee, Tridib N.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S3146 - S3149
  • [42] Evaluation of bone morphology in posterior mandible: A cone-beam computed tomography based study
    Arif, Aysha
    Khan, Farhan Raza
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2023, 73 (04) : 771 - 775
  • [43] Anatomical variations of maxillary sinus: a cone-beam computed tomography study
    Yazdani, Javad
    Parnia, Feridoun
    Torab, Ali
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2018, 8 (03): : 3298 - 3301
  • [44] Anatomical analyses for maxillary sinus floor augmentation with a lateral approach: A cone beam computed tomography study
    Kawakami, Shunsuke
    Botticelli, Daniele
    Nakajima, Yasushi
    Sakuma, Shigeru
    Baba, Shunsuke
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2019, 226 : 29 - 34
  • [45] Evaluation of the location of posterior superior alveolar artery and infraorbital foramen originating from the same source by using cone beam computed tomography
    Cam, Kubra
    Zengin, Ayse Zeynep
    BMC ORAL HEALTH, 2025, 25 (01):
  • [46] 3D-evaluation of the maxillary sinus in cone-beam computed tomography
    Julia Luz
    Dominique Greutmann
    Daniel Wiedemeier
    Claudio Rostetter
    Martin Rücker
    Bernd Stadlinger
    International Journal of Implant Dentistry, 4
  • [47] 3D-evaluation of the maxillary sinus in cone-beam computed tomography
    Luz, Julia
    Greutmann, Dominique
    Wiedemeier, Daniel
    Rostetter, Claudio
    Ruecker, Martin
    Stadlinger, Bernd
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [48] Evaluation of Posterior Superior Alveolar Canal in Individuals With Cleft Lip and Palate Using Cone Beam Computed Tomography
    Tannishtha, Tannishtha
    Babu, G. Subhas
    Shetty, Vikram
    Ajila, Vidya
    CLEFT PALATE CRANIOFACIAL JOURNAL, 2024,
  • [49] Is the panoramic radiography sufficient for detecting the relationship of the posterior maxillary teeth with maxillary sinus floor? A retrospective study comparative with cone-beam computed tomography
    Dogan, Fatma Busra
    Cetin, Bilgun
    Akgunlu, Faruk
    INTERNATIONAL JOURNAL OF HEALTH AND ALLIED SCIENCES, 2021, 10 (02): : 123 - 128
  • [50] Cone-beam computed tomographic analysis of sinus membrane thickness, ostium patency, and residual ridge heights in the posterior maxilla: implications for sinus floor elevation
    Shanbhag, Siddharth
    Karnik, Prabodh
    Shirke, Prashant
    Shanbhag, Vivek
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (06) : 755 - 760